Read from the datasheet this catalog row already cites, at https://www.recgroup.com/sites/default/files/2025-01/Web_DS_REC_Alpha_Pure-R_EN%20US.pdf, from the Standard Test Conditions block of the table whose power classes are 400 | 410 | 420 | 430; the 430 column is the one the catalog model REC430AA PURE-R names. Printed value: "8.52". Conditions as stated on that sheet. No value was taken from another column, from the NMOT/NOCT block, or from a name.
Where: PDF page 2, row "Nominal Power Current - IMPP(A)", column "430"
Read from the datasheet this catalog row already cites, at https://www.recgroup.com/sites/default/files/2025-01/Web_DS_REC_Alpha_Pure-R_EN%20US.pdf, from the Standard Test Conditions block of the table whose power classes are 400 | 410 | 420 | 430; the 430 column is the one the catalog model REC430AA PURE-R names. Printed value: "8.91". Conditions as stated on that sheet. No value was taken from another column, from the NMOT/NOCT block, or from a name.
Where: PDF page 2, row "Short Circuit Current - I (A)", column "430"
Read from the datasheet this catalog row already cites, at https://www.recgroup.com/sites/default/files/2025-01/Web_DS_REC_Alpha_Pure-R_EN%20US.pdf, from the Standard Test Conditions block of the table whose power classes are 400 | 410 | 420 | 430; the 430 column is the one the catalog model REC430AA PURE-R names. Printed value: "50.5". Conditions as stated on that sheet. No value was taken from another column, from the NMOT/NOCT block, or from a name.
Where: PDF page 2, row "Nominal Power Voltage - V (V)", column "430"
Read from the datasheet this catalog row already cites, at https://www.recgroup.com/sites/default/files/2025-01/Web_DS_REC_Alpha_Pure-R_EN%20US.pdf, from the Standard Test Conditions block of the table whose power classes are 400 | 410 | 420 | 430; the 430 column is the one the catalog model REC430AA PURE-R names. Printed value: "59.7". Conditions as stated on that sheet. No value was taken from another column, from the NMOT/NOCT block, or from a name.
Where: PDF page 2, row "STCOpen Circuit Voltage - VOC (V)", column "430"
Datasheet prints "Cell Type 80 half-cut bifacial REC heterojunction cells, with lead-free, gapless technology". Covers product code RECXXXAA PURE-R in the 400-430 W classes, which includes this model.
Read from the datasheet this catalog row already cites, at https://www.recgroup.com/sites/default/files/2025-01/Web_DS_REC_Alpha_Pure-R_EN%20US.pdf, from a row the sheet prints once for every model it covers, including REC430AA PURE-R. Printed value: "47.4 lb / 21.5 kg GR GR". Conditions as stated on that sheet. A value the sheet states more than once with different readings was not used.
Where: PDF page 2, row "Weight 47.4 lb / 21.5 kg GR GR"
0.13 in solar glass with anti-reflective surface treatment in accordance with EN12150
Printed as "Glass 0.13 in solar glass with anti-reflective surface treatment in accordance with EN12150" in REC Group's REC430AA PURE-R datasheet (REC Alpha Pure-R datasheet (UL, EN US)), captured on September 28, 2026.
Printed as "Backsheet Highly resistant polymer (Black)" in REC Group's REC430AA PURE-R datasheet (REC Alpha Pure-R datasheet (UL, EN US)), captured on September 28, 2026.
Where: Datasheet page 2, GENERAL DATA, Backsheet row
W 1,118 × H 1,730 × D 30 mm / W 44.02 × H 68.11 × D 1.2 in converted
Read from the datasheet this catalog row already cites, at https://www.recgroup.com/sites/default/files/2025-01/Web_DS_REC_Alpha_Pure-R_EN%20US.pdf, from a row the sheet prints once for every model it covers, including REC430AA PURE-R. Printed value: "1730 x 1118 x 30 mm". Conditions as stated on that sheet. A value the sheet states more than once with different readings was not used.
Where: PDF page 2, row "Dimensions 68.1 x 44.0 x 1.2 in (20.8 ft²) / 1730 x 1118 x 30 mm (1.93 m²) 20.5±"
Read from the datasheet this catalog row already cites, at https://www.recgroup.com/sites/default/files/2025-01/Web_DS_REC_Alpha_Pure-R_EN%20US.pdf, from a row the sheet prints once for every model it covers, including REC430AA PURE-R. Printed value: "25 A *IEC61730/UL61730 certified. Refer to installation manu". Conditions as stated on that sheet. A value the sheet states more than once with different readings was not used.
Read from the datasheet this catalog row already cites, at https://www.recgroup.com/sites/default/files/2025-01/Web_DS_REC_Alpha_Pure-R_EN%20US.pdf, from the Standard Test Conditions block of the table whose power classes are 400 | 410 | 420 | 430; the 430 column is the one the catalog model REC430AA PURE-R names. Printed value: "22.3". Conditions as stated on that sheet. No value was taken from another column, from the NMOT/NOCT block, or from a name.
Where: PDF page 2, row "Panel Efficiency (%)", column "430"
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Read from the datasheet this catalog row already cites, at https://www.recgroup.com/sites/default/files/2025-01/Web_DS_REC_Alpha_Pure-R_EN%20US.pdf, from the Standard Test Conditions block of the table whose power classes are 400 | 410 | 420 | 430; the 430 column is the one the catalog model REC430AA PURE-R names. Printed value: "22.3". Conditions as stated on that sheet. No value was taken from another column, from the NMOT/NOCT block, or from a name.
Standard REC product warranty. REC ProTrust extends this to 25 years when the panels are installed by an REC Certified Solar Professional and registered; system-size conditions apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
CECauthority listing reportedlisted as of snapshot[3]
Scope
equipment listing
Covered models
REC430AA PURE-R
Limitations
Model REC430AA PURE-R listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under REC Group, as "REC430AA Pure-R", CEC listing date 2022-12-12. The list prints "REC430AA Pure-R"; the record's model "REC430AA PURE-R" differs only in letter case. This is an equipment listing, not UL certification or complete-system approval.
Standard REC product warranty. REC ProTrust extends this to 25 years when the panels are installed by an REC Certified Solar Professional and registered; system-size conditions apply.
Where: Page 2, Warranty table, "Product Warranty (yrs)", Standard column
REC Group's own installation manual, captured September 28, 2026 with scripts/research/fetch.mjs from recgroup.com. IEC 61730 edition. Its cover states it is for all Alpha Pure solar panels certified to IEC 61215 & IEC 61730 and names REC Alpha Pure 2, REC Alpha Pure-R and REC Alpha Pure-RX. It is a series-level manual: it establishes installation, handling, mounting and safety instructions for those series, not model-specific ratings. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Location: Page 2, Electrical Data / General Data / Module Ratings
Retrieved Sep 19, 2026
Covers product code RECXXXAA PURE-R in the 400-430 W classes only; values are STC typicals with a +/-3% production spread and do not establish any other REC series.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
REC Group's own installation manual, captured September 28, 2026 with scripts/research/fetch.mjs from recgroup.com. UL 61730 edition, REF: PM-IM-23-06 REV: 18 UL EN 3.2026. Its cover states it is for all Alpha Pure solar panels certified to IEC 61215 & UL 61730 and names REC Alpha Pure 2, REC Alpha Pure-R and REC Alpha Pure-RX. It is a series-level manual: it establishes installation, handling, mounting and safety instructions for those series, not model-specific ratings. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
REC430AA PURE-R
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model REC430AA PURE-R listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under REC Group, as "REC430AA Pure-R", CEC listing date 2022-12-12. The list prints "REC430AA Pure-R"; the record's model "REC430AA PURE-R" differs only in letter case. This is an equipment listing, not UL certification or complete-system approval.