REC Group REC405AA PURE
- Brand
- REC Group
- Model
- REC405AA PURE
- SKU / part number
- REC405AA PURE Provisional [1]
- Category
- Solar panels
chargedreviews.com/panels/rec-group-rec405aa-pure
Electrical at STC
- Power tolerance
- ?
Temperature and system limits
Cells and construction
Mechanical and connections
Installation (from the manual)
Torque
- Clamp or bolt torque
- 12 to 25 N·m [2]
Conductors
- Cable bending radius / connector notes
- The cables must have a minimum bending radius of 1.2 in (30 mm) to avoid damage to the insulation (fig. 19), [2]
Clearances and orientation
- Mounting methods and clamp zones
- Such installations have been found to be in compliance with IEC 61215 & IEC 61730 requirements for the stated maximum test loads of: +7000 Pa downwards pressure and -4000 Pa upwards pressure (+4666 Pa/-2666 Pa design loads).; 14.8 - 19.9 in (375 - 505 mm) +1800 Pa / -1800 Pa * (+1200 Pa / -1200 Pa) +6200 Pa / -4000 Pa (+4133 Pa / -2666 Pa) +7000 Pa / -4000 Pa (+4666 Pa / -2666 Pa); The panel must be secured, e.g., clamped, at least once in each of the four marked zones shown below (fig. 2). [2]
Grounding
- Grounding
- Suitable grounding lugs must be used: Listed (KDER) ILSCO, GBL-4DBT (tin plated) (E34440),; Grounding cable size should be between 4 - 14 AWG (2.1 mm² - 21.2 mm²),; Fix lug to the frame using a star washer (#10) and lock nut (#10), ensuring a conductive connection, [2]