Charged ReviewsSaved 0Compare 0Login

Charged Reviews · Quick reference

REC Group REC390TP2SM 72

Brand
REC Group
Model
REC390TP2SM 72
SKU / part number
?
Category
Solar panels
No photo

chargedreviews.com/panels/rec-group-rec390tp2sm-72

Electrical at STC

Rated output (STC)
390 W [1]
Module efficiency
19.4 % [1]
Voltage at max power (Vmp)
40.7 V [1]
Current at max power (Imp)
9.58 A [1]
Open-circuit voltage (Voc)
49.2 V [1]
Short-circuit current (Isc)
10.08 A [1]
Power tolerance
?

Temperature and system limits

Temperature coefficient, Pmax
-0.37 %/°C [1]
Temperature coefficient, Voc
-0.28 %/°C [1]
Temperature coefficient, Isc
0.04 %/°C [1]
Maximum system voltage
1,000 V [1]
Maximum series fuse
?
NOCT / NMOT
?
Rated output at NMOT
?
Operating temperature
-40 to 85 °C / -40 to 185 °F converted [1]

Cells and construction

Cell technology
half-cut monocrystalline PERC [1]
Cell count
144 cells [1]
Bifacial
?
Bifaciality
?
Frame
Anodized aluminum [1]
Front glass
3.2 mm solar glass with anti-reflection surface treatment [1]
Back cover
Highly resistant polymeric construction [1]
Panel format
rigid [1]

Mechanical and connections

Dimensions
W 1,001 × L 2,005 × D 30 mm / W 39.41 × L 78.94 × D 1.2 in converted [1]
Weight
22 kg / 49 lb converted [1]
Connectors
Tonglin TL-Cable01S-F (4 mm²) in accordance with IEC 62852, IP68 only when connected [1]
Cable length
?
Junction box rating
?
Mounting
?
Design load, front
?
Design load, rear
?

Installation (from the manual)

Not documented in the manual

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

REC Group REC390TP2SM 72 · REC390TP2SM 72

Warranty

Product warranty20 years[1]
Power warranty term25 years[1]
First-year degradation?
Annual degradation after year one0.5 % Needs confirmation[1]
Warranted final output?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?

Certifications and listings

UL 61730Verified listed as of snapshot [2]
UL 1703Claimed present at observation [1]
IEC 61215Claimed present at observation [1]
IEC 61730Claimed present at observation [1]
IEC 62804Claimed present at observation [1]
CEC listing?
IEC 61701Claimed present at observation [1]
IEC 62716Claimed present at observation [1]
CECVerified listed as of snapshot [2]

Documents and sources

  1. REC TwinPeak 2S Mono 72 Series datasheet, UL edition (Ref: PM-DS-07-23 Rev-B 07.19) (Internet Archive copy, September 22, 2019) Manufacturer datasheet (Internet Archive copy) · Revision Ref: PM-DS-07-23 Rev-B 07.19 · Checked Sep 24, 2026 https://web.archive.org/web/20190922084303id_/https://www.recgroup.com/sites/default/files/documents/ds_rec_twinpeak_2s_mono_72_series_ul_rev_b_en_web_.pdf
  2. CEC PV Module List, official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) Government equipment list (spreadsheet) · Revision Data unchanged since October 1, 2026 · Revised Oct 1, 2026 · Checked Oct 10, 2026 https://solarequipment.energy.ca.gov/Home/DownloadtoExcel?filename=PVModuleList

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/panels/rec-group-rec390tp2sm-72Some links pay us a commission. That does not affect what we record.