Charged Reviews · Quick reference
REC Group REC315TP2M
- Brand
- REC Group
- Model
- REC315TP2M
- SKU / part number
- ?
- Category
- Solar panels
chargedreviews.com/panels/rec-group-rec315tp2m
Electrical at STC
Temperature and system limits
Cells and construction
Mechanical and connections
Installation (from the manual)
Conductors
- Cable bending radius / connector notes
- The cables on REC solar panels have a minimum bending radius of 1.2 in (30 mm) to avoid damage to the insulation (fig. 15). [1]
Clearances and orientation
- Mounting methods and clamp zones
- Clamps in the green zone: 8.2-16.4 in (208-416 mm) are certified for downward loads of 112 psf (DL: 3600 Pa) & upward loads of 50 psf (DL :1600 Pa); Clamps in the yellow zone: 0-8.2 in (0-208 mm) long side; 0-9.8 in (0 -250 mm) short side, are certified for downward & upward loads of 50 psf (DL :1600 Pa); Clamping in the red zone is not permitted (> 16.4 in (416 mm) on long side, > 9.8 in (250 mm) on short side), where only four clamping points are used; REC solar panels can be mounted utilizing the four 0,43 x 0,26 in (11 x 6.6 mm) elongated holes on the underside of the panel at a distance of 15 in (382.5 mm) from the corner; Mounting in this way has been found to be in compliance with UL 1703 requirements for test loads of up to 112 psf (5400 Pa, or a design load of 3600 Pa*) downward force and 50 psf (2400 Pa, or a design load of 1600 Pa*) upwards force [1]
Grounding
- Grounding
- Suitable grounding lugs must be used: Listed (KDER) ILSCO, GBL-4DBT (tin plated) (E34440).; Grounding cable size should be between 4 - 14 AWG (2.1 mm² - 21.2 mm²).; Attach grounds to the grounding holes in the panel frames.; Fix lug to the frame using a star washer (#10) and lock nut (#10), ensuring a conductive connection (fig. 10). [1]
Not in the manual: Torque