Charged ReviewsSaved 0Compare 0Login

Charged Reviews · Quick reference

REC Group REC300PE 72

Brand
REC Group
Model
REC300PE 72
SKU / part number
?
Category
Solar panels
No photo

chargedreviews.com/panels/rec-group-rec300pe-72

Electrical at STC

Rated output (STC)
300 W [1] [2]
Module efficiency
15.4 % [2]
Voltage at max power (Vmp)
36.5 V [1] [2]
Current at max power (Imp)
8.22 A [1] [2]
Open-circuit voltage (Voc)
44.9 V [1] [2]
Short-circuit current (Isc)
8.76 A [1] [2]
Power tolerance
?

Temperature and system limits

Temperature coefficient, Pmax
-0.4 %/°C [2]
Temperature coefficient, Voc
-0.27 %/°C [2]
Temperature coefficient, Isc
0.013 %/°C [2]
Maximum system voltage
1,000 V [2]
Maximum series fuse
?
NOCT / NMOT
?
Rated output at NMOT
?
Operating temperature
-40 to 85 °C / -40 to 185 °F converted [2]

Cells and construction

Cell technology
multicrystalline [2]
Cell count
72 cells [2]
Bifacial
?
Bifaciality
?
Frame
Anodized aluminum (silver) [2]
Front glass
4 mm solar glass with anti-reflection surface treatment [2]
Back cover
Highly resistant polyester [2]
Panel format
rigid [2]

Mechanical and connections

Dimensions
W 991 × L 1,968 × D 45 mm / W 39 × L 77.48 × D 1.8 in converted [2]
Weight
27 kg / 60 lb converted [2]
Connectors
MC4 type (4 mm²) [2]
Cable length
?
Junction box rating
?
Mounting
?
Design load, front
?
Design load, rear
?

Installation (from the manual)

Torque

Clamp or bolt torque
16 ft-lb [1]

Conductors

Cable bending radius / connector notes
The cables on the REC Peak Energy 72 have a minimum bending radius of 1.2 in (30 mm) to avoid damage to the insulation (fig. 10) [1]

Clearances and orientation

Mounting methods and clamp zones
Mounting utilizing clamps on the two long sides of the panel have been found to be in compliance with UL 1703 requirements for a maximum design load of 75.2 lbs/ft² (3600 Pa) (fig. 4).; Clamps must be secured between a distance of 9.8 in to 13.8 in (250 mm - 350 mm) from the clamp centerline to the end of the panel.; Installation of REC Peak Energy 72 panels using mounting holes complies with UL 1703 requirements for a maximum design load of 75.2 lbs/ft² (3600 Pa). [1]

Grounding

Grounding
Suitable grounding lugs must be used: Listed (KDER) ILSCO, GBL-4DBT (tin plated) (E34440).; Grounding cable size should be between 4 - 14 AWG (2.1 mm² - 21.2mm²).; Fix lug to the frame using a star washer (#10) and lock nut (#10), ensuring a conductive connection (fig. 9). [1]
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

REC Group REC300PE 72 · REC300PE 72

Warranty

Product warranty10 years[3]
Power warranty term25 years[3]
First-year degradation?
Annual degradation after year one0.7 %[3]
Warranted final output?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?

Certifications and listings

UL 61730?
UL 1703Claimed present at observation [2]
IEC 61215Claimed present at observation [2]
IEC 61730Claimed present at observation [2]
IEC 62804Claimed present at observation [2]
CEC listing?
IEC 61701Claimed present at observation [2]
IEC 62716Claimed present at observation [2]
ISO 11925-2Claimed present at observation [2]
MCSClaimed present at observation [2]
UNI 8457/9174Claimed present at observation [2]

Documents and sources

  1. REC Installation Manual, REC Peak Energy 72 (UL 1703 edition, Rev C.3, 02.16), Internet Archive copy of March 27, 2016 Installation manual (Internet Archive copy) · Revision Rev C.3 · Revised 2016-02 · Checked Oct 1, 2026 https://web.archive.org/web/20160327043258id_/http://www.recgroup.com:80/sites/default/files/installation_manual_rec_peak_energy_72_series_ul.pdf
  2. REC Peak Energy 72 Series datasheet, international edition (Ref: NE-05-05-06 - Rev.K - 08.2016) (Internet Archive copy, September 9, 2016) Manufacturer datasheet (Internet Archive copy) · Revision Ref: NE-05-05-06 - Rev.K - 08.2016 · Checked Sep 24, 2026 https://web.archive.org/web/20160909134029id_/http://www.recgroup.com:80/sites/default/files/documents/ds_rec_peak_energy_72_rev_k_eng.pdf
  3. REC Warranty Conditions, REC Peak Energy Products, Rev L (Ref: NE259231231) Manufacturer warranty · Revision Rev L · Checked Oct 17, 2026 https://www.recgroup.com/sites/default/files/documents/warranty_rec_peak_energy_rev_l_web.pdf

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/panels/rec-group-rec300pe-72Some links pay us a commission. That does not affect what we record.