Electrical at STC

Rated output (STC)
280 W [1] [2]
Module efficiency
16.8 % [1] [2]
Voltage at max power (Vmp)
31.7 V [1] [2]
Current at max power (Imp)
8.84 A [1] [2]
Open-circuit voltage (Voc)
38.4 V Needs confirmation [1]
Short-circuit current (Isc)
9.61 A Needs confirmation [1]
Power tolerance
?

Temperature and system limits

Temperature coefficient, Pmax
-0.36 %/°C [1] [2]
Temperature coefficient, Voc
-0.3 %/°C [1] [2]
Temperature coefficient, Isc
0.066 %/°C [1] [2]
Maximum system voltage
1,000 V [1] [2]
Maximum series fuse
20 A [1]
NOCT / NMOT
44.6 °C / 112.3 °F converted [1]
Rated output at NMOT
?
Operating temperature
-40 to 85 °C / -40 to 185 °F converted [1] [2]

Cells and construction

Cell technology
REC HC multicrystalline PERC [2]
Cell count
?
Bifacial
?
Bifaciality
?
Frame
Anodized aluminum (Available in silver or black) [2]
Front glass
0.13" (3.2 mm) solar glass with anti-reflective surface treatment [2]
Back cover
Highly resistant polyester polyolefin construction [2]
Panel format
rigid [2]

Mechanical and connections

Dimensions
W 997 × L 1,675 × D 38 mm / W 39.3 × L 65.94 × D 1.5 in converted [2]
Weight
18.5 kg / 40.8 lb converted [2]
Connectors
Stäubli MC4 PV-KBT4/PV-KST4, 12 AWG (4 mm²) [2]
Cable length
?
Junction box rating
IP67 [1]
Mounting
?
Design load, front
?
Design load, rear
?

Installation (from the manual)

Conductors

Cable bending radius / connector notes
The cables on REC solar panels have a minimum bending radius of 1.2 in (30 mm) to avoid damage to the insulation (fig. 15). [1]

Clearances and orientation

Mounting methods and clamp zones
Clamps in the green zone: 8.2-16.4 in (208-416 mm) are certified for downward loads of 112 psf (DL: 3600 Pa) & upward loads of 50 psf (DL :1600 Pa); Clamps in the yellow zone: 0-8.2 in (0-208 mm) long side; 0-9.8 in (0 -250 mm) short side, are certified for downward & upward loads of 50 psf (DL :1600 Pa); Clamping in the red zone is not permitted (> 16.4 in (416 mm) on long side, > 9.8 in (250 mm) on short side), where only four clamping points are used; REC solar panels can be mounted utilizing the four 0,43 x 0,26 in (11 x 6.6 mm) elongated holes on the underside of the panel at a distance of 15 in (382.5 mm) from the corner; Mounting in this way has been found to be in compliance with UL 1703 requirements for test loads of up to 112 psf (5400 Pa, or a design load of 3600 Pa*) downward force and 50 psf (2400 Pa, or a design load of 1600 Pa*) upwards force [1]

Grounding

Grounding
Suitable grounding lugs must be used: Listed (KDER) ILSCO, GBL-4DBT (tin plated) (E34440).; Grounding cable size should be between 4 - 14 AWG (2.1 mm² - 21.2 mm²).; Attach grounds to the grounding holes in the panel frames.; Fix lug to the frame using a star washer (#10) and lock nut (#10), ensuring a conductive connection (fig. 10). [1]

Not in the manual: Torque

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

REC Group REC280TP2 · REC280TP2

Warranty

Product warranty20 years[3]
Power warranty term25 years[3]
First-year degradation?
Annual degradation after year one0.7 %[3]
Warranted final output?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?

Certifications and listings

UL 61730Verified listed as of snapshot [4] [5]
UL 1703Claimed present at observation [2]
IEC 61215Claimed present at observation [2]
IEC 61730Claimed present at observation [2]
IEC 62804Claimed present at observation [2]
CEC listing?
IEC 60068-2-68Claimed present at observation [2]
IEC 61701Claimed present at observation [2]
IEC 62716Claimed present at observation [2]
ISO 11925-2Claimed present at observation [2]
CECVerified listed as of snapshot [5]

Documents and sources

  1. REC Installation Manual, REC 60-Cell Panels (UL 1703 edition, Rev C.2, 01.19), Internet Archive copy of April 24, 2019 Installation manual (Internet Archive copy) · Revision Rev C.2 · Revised 2019-01 · Checked Oct 1, 2026 https://web.archive.org/web/20190424170552id_/https://www.recgroup.com/sites/default/files/documents/im_rec_twinpeak_series_ul_rev_f.2_eng.pdf
  2. REC TwinPeak 2 Series datasheet, UL edition (Ref: PM-DS-07-07 Rev- I 07.19) (Internet Archive copy, October 15, 2019) Manufacturer datasheet (Internet Archive copy) · Revision Ref: PM-DS-07-07 Rev- I 07.19 · Checked Sep 24, 2026 https://web.archive.org/web/20191015102132id_/https://www.recgroup.com/sites/default/files/documents/ds_rec_twinpeak_2_series_ul_rev_i_en_web.pdf
  3. REC Warranty Conditions, REC TwinPeak, Rev D (Ref: PM2WARR27) Manufacturer warranty · Revision Rev D · Checked Oct 17, 2026 https://www.recgroup.com/sites/default/files/documents/warranty_tp_rev_d.pdf
  4. California Energy Commission PVModuleList full official workbook, data 2026-11-02 Government equipment list (spreadsheet) · Revision Data unchanged since 2026-11-02 · Revised Nov 2, 2026 · Checked Nov 6, 2026 https://solarequipment.energy.ca.gov/Home/DownloadtoExcel?filename=PVModuleList
  5. CEC PV Module List, official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) Government equipment list (spreadsheet) · Revision Data unchanged since October 1, 2026 · Revised Oct 1, 2026 · Checked Oct 10, 2026 https://solarequipment.energy.ca.gov/Home/DownloadtoExcel?filename=PVModuleList

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.