Electrical at STC
Temperature and system limits
Cells and construction
Mechanical and connections
Installation (from the manual)
Conductors
- Cable bending radius / connector notes
- The cables on REC Peak Energy panels have a minimum bending radius of 30 mm to avoid damage to the insulation (Fig. 9). [2]
Clearances and orientation
- Mounting methods and clamp zones
- Clamping within the green zone (208 - 416 mm) is certified for design loads up to 5400 Pa (550 kg/m²); Clamping within the yellow zone (0 - 208 mm long side, 250 mm short side) is certifed for design loads up to 2400 Pa (244 kg/m²); Clamping within the red zone is not permitted (> 416 mm long side, > 250 mm short side) when only using four clamps; REC Peak Energy panels can also be secured to the mounting structure using the mounting holes (fig. 5) found on the underside of the frame (6.6 x 11 mm, spaced 450 mm from the midpoint of the long side). [2]
Grounding
- Grounding
- Suitable grounding lugs must be used.; Grounding cable size should be between 2.1 mm² - 21.2 mm².; Fix lug to the frame using a star washer and lock nut, ensuring a conductive connection (fig. 8).; Place the star washer between the frame and the nut, using a 5 mm diameter stainless steel bolt and locking nut to mount the lug to the panel frame and tighten according to the manufacturer’s recommended torque. [2]
Not in the manual: Torque