Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Greentech Renewables's product image of the Qcells Q.PEAK DUO XL-G10.D/BFG 490 on its own store listing.No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Bifacial | yes Provisional | Seller-listed specification; not independently verified. Where: Product category | [1] |
| Cell type | Q.ANTUM DUO Z Provisional | Seller-listed specification; not independently verified. Where: technology | [1] |
| Grounding | Option A: Use of a grounding lug. A listed grounding lug can be bonded to the frame using the grounding holes pre-drilled in the frame.; The grounding lug should be attached to the frame grounding hole using a stainless steel screw, toothed lock washer or KEPS nut (in order to penetrate the anodized layer) and backing nut.; Option B: Integrated grounding methods. The Q CELLS modules can be bonded with the racking system using UL61730 or UL2703 certified integrated grounding methods. | Printed as "A listed grounding lug can be bonded to the frame using the grounding holes pre-drilled in the frame." in Qcells' Installation and Operation Manual for Q.PEAK DUO XL-G10.X / BFG and XL-G10.X / BGT solar modules (North America, document revision 01, 2021), section 5 Grounding, Option A (grounding lug, stainless steel or tin plated, through the frame grounding holes of 0.177 in) and Option B (integrated grounding, for example WEEB washers). The frame and all non-current-carrying metal parts must be grounded (NEC Article 250). Where: PDF page 12, section 5 Grounding (Option A and Option B) | [2] |
| Weight | 29.1 kg / 64.2 lb converted | Printed as "Weight [lbs] 64.2 (29.1 kg)" in Qcells' Installation and Operation Manual for Q.PEAK DUO XL-G10.X / BFG and XL-G10.X / BGT solar modules (North America, document revision 01, 2021), section 2.1 Technical Specifications (product line Q.PEAK DUO XL-G10.3 / BFG, XL-G10.3 / BGT, XL-G10.d / BFG, XL-G10.d / BGT). The kilogram figure printed in brackets. Revised on 1 October 2026: Owner source order puts the installation manual first: Qcells' installation manual for the Q.PEAK DUO XL-G10.X / BFG series prints 29.1 kg; the earlier value 29.1206 kg came from a seller product page (Greentech Renewables) and is kept beside it. Where: PDF page 3, section 2.1 Technical Specifications (product line Q.PEAK DUO XL-G10.3 / BFG, XL-G10.3 / BGT, XL-G10.d / BFG, XL-G10.d / BGT) Sources29.1 kg Seller-listed specification; not independently verified. [1] | [2] |
| Dimensions | W 1,045 × L 2,216 × D 35 mm / W 41.14 × L 87.24 × D 1.4 in converted | Printed as "Length [in] 87.2 (2216 mm) Width [in] 41.1 (1045 mm) Frame height [in] 1.38 (35 mm)" in Qcells' Installation and Operation Manual for Q.PEAK DUO XL-G10.X / BFG and XL-G10.X / BGT solar modules (North America, document revision 01, 2021), section 2.1 Technical Specifications (product line Q.PEAK DUO XL-G10.3 / BFG, XL-G10.3 / BGT, XL-G10.d / BFG, XL-G10.d / BGT). The millimeter figures printed in brackets. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source. Where: PDF page 3, section 2.1 Technical Specifications (product line Q.PEAK DUO XL-G10.3 / BFG, XL-G10.3 / BGT, XL-G10.d / BFG, XL-G10.d / BGT) | [2] [1] |
| Rated power | 490 W Provisional | Seller-listed specification; not independently verified. Where: watts-stc | [1] |
| Series fuse | 20 A Provisional | Seller-listed specification; not independently verified. Where: series-fuse-rating | [1] |
| Mounting methods | CL1a, clamps at 11.8 - 21.6 in (300 - 550 mm): test load push / pull 5400 / 3000 Pa, design load push / pull 3600 / 2000 Pa; CL1b, clamps at 11.8 - 21.6 in (300 - 550 mm): test load 2900 / 3000 Pa, design load 1930 / 2000 Pa; FB1, mounting slots at 17.9 in (454 mm): test load 5400 / 3000 Pa, design load 3600 / 2000 Pa; FB2 and mFB2, mounting slots at 17.9 in (454 mm), and CL3, clamps at 11.8 - 21.6 in (300 - 550 mm): test load 3600 / 3000 Pa, design load 2400 / 2000 Pa; mCL3, clamps at 11.8 - 21.6 in (300 - 550 mm): test load 3300 / 3000 Pa, design load 2200 / 2000 Pa; CL5, short side 0.8 - 3.9 in (20 - 100 mm), long side 19.7 - 23.6 in (500 - 600 mm): test load 2400 / 2400 Pa, design load 1600 / 1600 Pa; Tracker options: TB1b and TB2b 3000 / 3000 Pa (design 2000 / 2000 Pa); TB1a 2400 / 2400 Pa (design 1600 / 1600 Pa); TB2a 2700 / 2400 Pa (design 1800 / 1600 Pa); TC1 2200 / 2200 Pa (design 1460 / 1460 Pa); Only under certain conditions: CL1a at 0.8 - 21.6 in (20 - 550 mm) 2000 / 2000 Pa (design 1330 / 1330 Pa); CL2b at 0.8 - 3.9 in (20 - 100 mm) 1600 / 1600 Pa (design 1060 / 1060 Pa) | Printed as "CL1a 11.8 - 21.6 (300 - 550) 5400 / 3000 3600 / 2000 1.5" in Qcells' Installation and Operation Manual for Q.PEAK DUO XL-G10.X / BFG and XL-G10.X / BGT solar modules (North America, document revision 01, 2021), section 2.3 Mounting Options: each mounting option with the position of clamps (distance from the outer edge of the module to the middle of the clamp, in inches with millimeters in brackets), test load push / pull and design load push / pull in Pa, safety factor 1.5. Rows that share one load cell (FB2, mFB2 and CL3; TB1b and TB2b) were grouped as read from rendered page 6. The last two options do not fulfill the requirements of the standards, as the table footnote states. Clamps: width at least 1.5 in (38 mm), depth 0.2 - 0.47 in (5 - 12 mm); tighten clamps and screws according to the manufacturer's instructions (no torque is printed). Where: PDF page 6, section 2.3 Mounting Options, Specifications table (with Fig. 2 on PDF page 5) | [2] |
| Cable bend radius | Comply with bending radius of ≥ 2.36 in (60 mm) | Printed as "Comply with bending radius of ≥ 2.36 in (60 mm)" in Qcells' Installation and Operation Manual for Q.PEAK DUO XL-G10.X / BFG and XL-G10.X / BGT solar modules (North America, document revision 01, 2021), section 4.3 Connection of modules. Printed in the note "Ensure that the cabling is not under mechanical stress". Where: PDF page 11, section 4.3 Connection of modules | [2] |
| Max series fuse | 20 A | Printed as "Max. series fuse rating 20 A" in Qcells' Installation and Operation Manual for Q.PEAK DUO XL-G10.X / BFG and XL-G10.X / BGT solar modules (North America, document revision 01, 2021), section 2.1 Technical Specifications (product line Q.PEAK DUO XL-G10.3 / BFG, XL-G10.3 / BGT, XL-G10.d / BFG, XL-G10.d / BGT). One figure for the product line. Where: PDF page 3, section 2.1 Technical Specifications (product line Q.PEAK DUO XL-G10.3 / BFG, XL-G10.3 / BGT, XL-G10.d / BFG, XL-G10.d / BGT) | [2] |
| Junction box rating | ≥ IP67 | Printed as "Junction box protection class ≥ IP67 with bypass diode" in Qcells' Installation and Operation Manual for Q.PEAK DUO XL-G10.X / BFG and XL-G10.X / BGT solar modules (North America, document revision 01, 2021), section 2.1 Technical Specifications (product line Q.PEAK DUO XL-G10.3 / BFG, XL-G10.3 / BGT, XL-G10.d / BFG, XL-G10.d / BGT). Printed with "≥" (at least IP67). Where: PDF page 3, section 2.1 Technical Specifications (product line Q.PEAK DUO XL-G10.3 / BFG, XL-G10.3 / BGT, XL-G10.d / BFG, XL-G10.d / BGT) | [2] |
| Max system voltage | 1,500 V | Printed as "Max. system voltage VSYS 1500 V (IEC) / 1500 V (UL)" in Qcells' Installation and Operation Manual for Q.PEAK DUO XL-G10.X / BFG and XL-G10.X / BGT solar modules (North America, document revision 01, 2021), section 2.1 Technical Specifications (product line Q.PEAK DUO XL-G10.3 / BFG, XL-G10.3 / BGT, XL-G10.d / BFG, XL-G10.d / BGT). The same 1500 V for the IEC and UL ratings, one figure for the product line. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source. Where: PDF page 3, section 2.1 Technical Specifications (product line Q.PEAK DUO XL-G10.3 / BFG, XL-G10.3 / BGT, XL-G10.d / BFG, XL-G10.d / BGT) | [2] [1] |
| Module efficiency | 23.1 % Provisional | Seller-listed specification; not independently verified. Where: efficiency | [1] |
| Operating temperature | -40 to 85 °C / -40 to 185 °F converted | Printed as "Permissible temperature range –40 °F to +185 °F (–40 °C to +85 °C)" in Qcells' Installation and Operation Manual for Q.PEAK DUO XL-G10.X / BFG and XL-G10.X / BGT solar modules (North America, document revision 01, 2021), section 2.1 Technical Specifications (product line Q.PEAK DUO XL-G10.3 / BFG, XL-G10.3 / BGT, XL-G10.d / BFG, XL-G10.d / BGT). The Celsius figures printed in brackets. Where: PDF page 3, section 2.1 Technical Specifications (product line Q.PEAK DUO XL-G10.3 / BFG, XL-G10.3 / BGT, XL-G10.d / BFG, XL-G10.d / BGT) | [2] |
| Temperature coefficient | -0.34 %/°C Provisional | Seller-listed specification; not independently verified. Where: temp-coefficient-pmpp | [1] |
No reviews. Be the first to review this product:
Write a review
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Module efficiency needed; Product warranty needed; Power warranty needed; Power temperature coefficient needed; First-year degradation needed; Weight / watt needed.
Not enough comparable data for a score. None of this panel's scored inputs has a documented, sourced value yet. On file but not counted, because it is provisional, warned or has no source: module efficiency, power temperature coefficient, weight / watt.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
A documented panel weight and rated output are required.
A value is on file but is not counted: it carries a warning or is not confirmed.
Not documented, 0 points: Product warranty, Power warranty, First-year degradation.
Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4
How it worksA green check means we found this model, with that standard, on the certifier's own listing, the test lab's own report, or the California Energy Commission's equipment list.
Unknown: no warranty facts recorded.
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Archived copy captured on 2026-10-01.
Location: PDF page 2 (introduction, validity) and PDF page 3 (2.1 Technical Specifications)
Retrieved Oct 1, 2026
Qcells' own installation and operation manual for the Q.PEAK DUO XL-G10.X / BFG and XL-G10.X / BGT series, valid for North America as of July 1st 2021 for Q.PEAK DUO XL-G10.3 / BFG, XL-G10.3 / BGT, XL-G10.d / BFG and XL-G10.d / BGT modules (introduction). Printed as document revision 01 (back page: 2021-06_Rev01_NA; the file name Qcells used reads 2021-07_Rev02_NA). Qcells no longer serves the file; captured 1 October 2026 as the Internet Archive copy of August 7, 2024 of the file us.qcells.com then served. It gives one technical specification block for the product line and series-level mounting, grounding and wiring instructions; electrical ratings are left to the data sheet. Manufacturer instructions, not independent tests.
Location: Product listing
Retrieved Sep 16, 2026
No sourced accessories or replacement parts listed yet.
Manufacturer SKU Q.PEAK DUO XL-G10.D/BFG 490
Observed Oct 11, 2026
Product / system scope unresolved. Model Q.PEAK DUO XL-G10.D/BFG 490 listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Qcells North America, as "Q.PEAK DUO XL-G10.d/BFG 490", CEC listing date 2021-07-21. The list prints "Q.PEAK DUO XL-G10.d/BFG 490"; the record's model "Q.PEAK DUO XL-G10.D/BFG 490" differs only in letter case. This is an equipment listing, not UL certification or complete-system approval.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: panels-0.4-personal documented pct: 0 basis: Unknown missing: Module efficiency needed Product warranty needed Power warranty needed Power temperature coefficient needed First-year degradation needed Weight / watt needed criteria: key: efficiency label: Module efficiency value: Unknown unit: Unknown shown: 23.1 % · not confirmed shown detail: Unknown state: unconfirmed points: 0 ceiling: 26 weight: 26 share: Unknown covered: no missing: yes folded: no reason: not-counted reason text: A value is on file but is not counted: it carries a warning or is not confirmed. note: Not documented. display note: Unknown Sources: [1] key: warranty label: Product warranty value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 21 weight: 21 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: performanceWarranty label: Power warranty value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: powerTemperature label: Power temperature coefficient value: Unknown unit: Unknown shown: -0.34 %/°C · not confirmed shown detail: Unknown state: unconfirmed points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: no reason: not-counted reason text: A value is on file but is not counted: it carries a warning or is not confirmed. note: Not documented. display note: Unknown Sources: [1] key: degradation label: First-year degradation value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: weightPerWatt label: Weight / watt value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 5 weight: 5 share: Unknown covered: no missing: yes folded: no reason: not-counted reason text: A value is on file but is not counted: it carries a warning or is not confirmed. note: A documented panel weight and rated output are required. display note: Unknown | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.