Electrical at STC
Temperature and system limits
Cells and construction
Mechanical and connections
Installation (from the manual)
Torque
- Clamp or bolt torque
- 16 to 20 N·m [3]
Conductors
- Cable bending radius / connector notes
- The minimum bending radius of the cables must be 43mm. [3]
Clearances and orientation
- Mounting methods and clamp zones
- A. Mounting with Bolts 4-φ9*14mm mounting holes, (Applicable to framed Double-glass and framed Bifacial double-glass); Length≤2400mm Uplift load ≤2400Pa Downforce load ≤5400Pa; 2000<Length≤2400mm Uplift load ≤2400Pa Downforce load ≤2400Pa; Mounting with Clamps applied for framed Double-glass and Bifacial double-glass; The clamp must overlap the module frame by at least 7mm but no more than 10mm.; Use at least 4 clamps to attach modules to the mounting rails.; Length≤2400mm Uplift load ≤2400Pa Downforce load ≤5400Pa; 2000<Length≤2400mm Uplift load ≤2400Pa Downforce load ≤2400Pa [3]
Grounding
- Grounding
- On a grounding hole with a diameter of φ4 mm, use a separate grounding wire and related accessories to connect the aluminum frame of the solar PV module and connect the grounding wire to the ground.; The grounding uses the M4*12mm bolts and M4 nuts, star washers and plain washers, this ensures that the modules are firmly grounded.; The torque applied to ground fixation is 4N·m~8N·m.; It is recommended to use the copper wire (4-14mm2 or AWG 6-12) as the grounding wire. [3]