Charged Reviews · Quick reference
Panasonic HIT® Black N310K
- Brand
- Panasonic
- Model
- VBHN310KA01
- SKU / part number
- ?
- Category
- Solar panels
chargedreviews.com/panels/panasonic-vbhn310ka01
Electrical at STC
- Module efficiency
- 18.5 % [2]
- Power tolerance
- ?
Temperature and system limits
Cells and construction
Mechanical and connections
Installation (from the manual)
Torque
- Clamp or bolt torque
- 10 ft-lb [1]
Clearances and orientation
- Mounting methods and clamp zones
- The modules should be mounted at the four (4) quarter points by the means shown in Figure 2.; This method offers a maximum load of 2,400 N/m2 (50PSF) in a static state on the module surface.; Fixing span must be between 1030-1230mm [1]
Grounding
- Grounding
- Each ledge on the module frame has two larger holes for bolts (0.205’‘diameter (5.2 mm)).; Star washers must be used to make contact through the anodization of the module frame.; Recommended torque value in tightening bolt and nut is 2.3 N.m (20in-lb).; Use Tyco Electronics 1954381-2 as grounding clip. [1]
Not in the manual: Conductors