Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Panasonic EVPV410H image published by GreenTech Renewables on its listing for this product. Distributor photo, not a manufacturer-issued image.No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Current at max power | 9.61 A | Printed as "Maximum Power Current (lpm) 9.61A 9.51A" (the EVPV410H column) in Panasonic's EverVolt datasheet RS23101DS-R2 for EVPV410H and EVPV400H, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026). Where: Datasheet RS23101DS-R2, Electrical/Mechanical Specifications, Maximum Power Current (Ipm), EVPV410H column | [2] [1] |
| Short-circuit current | 10.35 A | Printed as "Short Circuit Current (lsc) 10.35A 10.25A" (the EVPV410H column) in Panasonic's EverVolt datasheet RS23101DS-R2 for EVPV410H and EVPV400H, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026). Where: Datasheet RS23101DS-R2, Electrical/Mechanical Specifications, Short Circuit Current (Isc), EVPV410H column | [2] [1] |
| Voltage at max power | 42.7 V | Printed as "Maximum Power Voltage (Vpm) 42.7V 42.1V" (the EVPV410H column) in Panasonic's EverVolt datasheet RS23101DS-R2 for EVPV410H and EVPV400H, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026). Where: Datasheet RS23101DS-R2, Electrical/Mechanical Specifications, Maximum Power Voltage (Vpm), EVPV410H column | [2] [1] |
| Open-circuit voltage | 49 V | Printed as "Open Circuit Voltage (Voc) 49.0V 48.8V" (the EVPV410H column) in Panasonic's EverVolt datasheet RS23101DS-R2 for EVPV410H and EVPV400H, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026). Where: Datasheet RS23101DS-R2, Electrical/Mechanical Specifications, Open Circuit Voltage (Voc), EVPV410H column | [2] [1] |
| Cell type | Silicon hetero-junction Check note | Panasonic's installation manual and a distributor's listing differ for this field. Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022) prints Silicon hetero-junction for EVPV410H; a distributor's listing recorded earlier gives Monocrystalline. The manual's value is shown first; the earlier value is kept below. Printed as "Cell Type Silicon hetero-junction*" in Table 1. EVPVxxxH, EVPVXXX, EVPVXXXK SERIES of Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022), one cell across all columns, with the footnote "*Mono-crystalline silicon/ amorphous silicon hetero-junction". Revised on 1 October 2026: The installation manual, first in the owner's source order, prints a different value for this model than a distributor's listing recorded earlier; the recorded value is kept beside it.Where: PDF page 6, Table 1. EVPVxxxH, EVPVXXX, EVPVXXXK SERIES, Cell Type row SourcesMonocrystalline Seller-listed specification; not independently verified. [1] | [3] |
| Grounding | EVERVOLT® modules have a small round grounding hole positioned near each corner of the module on both the long side and the short side; Suitable grounding lugs must be used: Listed (KDER) ILSCO, GBL- 4DBT (tin plated) (E34440); Grounding cable size should be between 4 - 14 AWG (2.1 mm² - 21.2 mm²); Fix lug to the frame using a star washer and lock nut, ensuring a conductive connection | Printed as "EVERVOLT® modules have a small round grounding hole positioned near each corner of the module on both the long side and the short side", "Suitable grounding lugs must be used: Listed (KDER) ILSCO, GBL- 4DBT (tin plated) (E34440)", "Grounding cable size should be between 4 - 14 AWG (2.1 mm² - 21.2 mm²)" and "Fix lug to the frame using a star washer and lock nut, ensuring a conductive connection" under Earth Ground Wiring in Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022); statements for all the EVERVOLT series it covers. Where: PDF page 22, Earth Ground Wiring | [3] |
| Weight | 20.5 kg / 45.2 lb converted Check note | Panasonic's installation manual and a distributor's listing differ for this field. Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022) prints 20.5 kg for EVPV410H; a distributor's listing recorded earlier gives 20.41 kg. The manual's value is shown first; the earlier value is kept below. Printed as "Weight 45.0 lbs (20.5kg)" in Panasonic's EverVolt datasheet RS23101DS-R2 for EVPV410H and EVPV400H, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026).Where: Datasheet RS23101DS-R2, Electrical/Mechanical Specifications, Weight Sources20.41 kg Printed as "Weight 45 Lbs." in the Panasonic EverVolt 410W 132 Half-Cell HJT 1000V WHT/BLK Solar Panel, EVPV410H; the maker prints pounds only, converted to kilograms. Revised on 30 September 2026: The maker prints this weight in pounds only; the stored kilograms were an unlabeled conversion, now labeled with the printed pounds kept (Project Manager, September 30, 2026). [1] | [2] |
| Clamp torque | 8.8 to 18.4 ft-lb | Printed as "EVERVOLT® modules must be secured with a torque between 8.8-18.4 ft- lb (12 - 25 Nm)." under Use of Rails and Clamps in Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022) (the first printed unit is "ft- lb", with "12 - 25 Nm" in parentheses); the same sentence is printed for mounting holes on PDF page 20. A statement for all the EVERVOLT series it covers. Where: PDF page 10, Use of Rails and Clamps | [3] |
| Dimensions | W 1,016 × L 1,821 × D 30 mm / W 40 × L 71.69 × D 1.2 in converted | Printed as "Dimensions LxWxH 71.7 x 40.0 x 1.2 in (1821 x 1016 x 30 mm)" in Panasonic's EverVolt datasheet RS23101DS-R2 for EVPV410H and EVPV400H, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026). Where: Datasheet RS23101DS-R2, Electrical/Mechanical Specifications, Dimensions LxWxH | [2] [1] |
| Rated power | 410 W | Printed as "Rated Power (Pmax)¹ 410W 400W" (the EVPV410H column) in Panasonic's EverVolt datasheet RS23101DS-R2 for EVPV410H and EVPV400H, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026). Where: Datasheet RS23101DS-R2, Electrical/Mechanical Specifications, Rated Power (Pmax), EVPV410H column | [2] [1] |
| Series fuse | 25 A Provisional | Seller-listed specification; not independently verified. Where: series-fuse-rating | [1] |
| Mounting methods | Installing the EVERVOLT® modules with clamps and rails has been found to comply with UL 61730 requirements for downward pressure, e.g., snow, of up to 7000 Pa (4666 Pa design load*) and upward pressure, e.g., wind, of up to 4000 Pa (2666 Pa design load*); The module must be secured, e.g., clamped, at least once in each of the four marked zones shown below (Figure. 8).; MOUNTING EVPVXXXH AND EVPVXXXHK SERIES MODULES WITH CONTINOUS RAILS PARALLEL TO SHORT SIDE OF THE MODULE; MOUNTING EVPVXXXH AND EVPVXXXHK SERIES MODULES WITH CONTINOUS RAILS PARALLEL TO LONG SIDE OF THE MODULE; MOUNTING EVPVXXXH AND EVPVXXXHK SERIES MODULES WITH SHORT RAILS; Installing the EVERVOLT® modules using the mounting holes has been found to comply with UL 61730 requirements for downward pressure,e.g., snow, of up to 5400 Pa (3600 Pa design load*) and upward pressure,e.g., wind, of up to 2400 Pa (1600 Pa design load*); All four mounting holes in the frame must be used (Figure 21). | Printed as "Installing the EVERVOLT® modules with clamps and rails has been found to comply with UL 61730 requirements for downward pressure, e.g., snow, of up to 7000 Pa (4666 Pa design load*) and upward pressure, e.g., wind, of up to 4000 Pa (2666 Pa design load*)" (PDF page 10) and "Installing the EVERVOLT® modules using the mounting holes has been found to comply with UL 61730 requirements for downward pressure" (PDF page 20, with the loads quoted in the value) in Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022). The clamping-zone tables for this series (PDF pages 14 to 16) give separate test and design loads for each clamping zone and clearance gap, and say "If the panel is secured in zones with different load values, it is rated to the lowest load value only." Loads vary by mounting method, zone and gap, so no single front or rear load is recorded. Where: PDF page 10, Use of Rails and Clamps; PDF pages 14 to 16, clamping tables; PDF page 20, Mounting Holes | [3] |
| Cable bend radius | The cables must have a minimum bending radius of 1.2 in (30 mm) to avoid damage to the insulation | Printed as "The cables must have a minimum bending radius of 1.2 in (30 mm) to avoid damage to the insulation" under Cable Management in Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022), a statement for all the EVERVOLT series it covers. Where: PDF page 9, Cable Management | [3] |
| Max series fuse | 25 A | Printed as "Maximum Series Fuse 25 A" in Panasonic's EverVolt datasheet RS23101DS-R2 for EVPV410H and EVPV400H, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026). Where: Datasheet RS23101DS-R2, Electrical/Mechanical Specifications, Maximum Series Fuse | [2] |
| Max system voltage | 1,000 V | Printed as "Maximum System Voltage 1000V" in Panasonic's EverVolt datasheet RS23101DS-R2 for EVPV410H and EVPV400H, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026). Where: Datasheet RS23101DS-R2, Electrical/Mechanical Specifications, Maximum System Voltage | [2] [1] |
| Module efficiency | 22.2 % Provisional | Seller-listed specification; not independently verified. Where: efficiency | [1] |
| Operating temperature | -40 to 85 °C / -40 to 185 °F converted | Printed as "Operating Temperature -40ºF to 185ºF (-40ºC to 85ºC)" in Panasonic's EverVolt datasheet RS23101DS-R2 for EVPV410H and EVPV400H, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026). Where: Datasheet RS23101DS-R2, Electrical/Mechanical Specifications, Operating Temperature | [2] |
| Temperature coefficient | -0.26 %/°C Provisional | Seller-listed specification; not independently verified. Where: temp-coefficient-pmpp | [1] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Module efficiency needed; Product warranty needed; Power warranty needed; Power temperature coefficient needed; First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
0.05 kg per W is the less favorable figure the maker's documents print, and it is scored because they disagree; it never sets or raises the bar. The bar is 0.01227 kg per W, the lowest documented for a solar panel, calculated from maker figures: Go Power! 110-Watt Solar Flex™ Module
20.5 kg / 410 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.
The maker's documents disagree; the less favorable printed figure, 0.05 kg per W, is scored. Warning: Panasonic's installation manual and a distributor's listing differ for this field.
Not documented, 0 points: Product warranty, Power warranty, First-year degradation.
Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4
How it worksUnknown: no warranty facts recorded.
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Internet Archive copy dated July 15, 2024 (the archive's own date); read on October 1, 2026.
Location: Cover page (series) and PDF pages 6 and 7 (Tables 1 and 2)
Retrieved Oct 1, 2026
Panasonic's own installation manual for its EVERVOLT modules, originally at https://ftp.panasonic.com/solar/installation/evervolt_solar_k_install.pdf, which Panasonic's solar support page links as the "EVPVxxx, EVPVxxxK Modules Installation Manual"; the archived file is Revision C of 11.15.2022, whose cover names the EVPVXXX, EVPVXXXK, EVPVXXXH, EVPVXXXPK and EVPVXXXHK series. Tables 1 and 2 print per-model ratings for EVPV410H, 400H, 390H, 380, 370, 360, 370K, 360K, 370PK, 360PK, 350PK, 410HK, 400HK and 390HK; it does not cover the HK2 models. North American edition (UL 61730, NEC). Series-level instruction otherwise. Panasonic's own host ftp.panasonic.com disallows all robots, so this is an archived copy: the Internet Archive captured Panasonic's own file on 15 July 2024, and that archived copy was read on 1 October 2026. It is labeled as an archived copy, not a current download from Panasonic. Manufacturer instructions, not independent tests.
Linked from the GreenTech Renewables product page with link text "View".
Location: ZZ299700048_DS.pdf
Retrieved Sep 18, 2026
Original PDF preserved byte for byte, found linked from the GreenTech Renewables listing https://www.greentechrenewables.com/product/panasonic-evervolt-400w-132-half-cell-hjt-1000v-whtblk-solar-panel-evpv400h. The revision is whatever was published at this URL on the access date; exact variant coverage inside the document was not separately verified and no later revision was checked.
SHA-256: bee15c459848d448a85666bc0eed0b2bab098e42b9f90d9dfa1b19959456e175
Archived copy of a document published by Panasonic. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Panasonic published. Original address: https://cdn.myced.com/images/Products/ZZ0000/ZZ2997/00000/ZZ299700048_DS.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: bee15c459848d448a85666bc0eed0b2bab098e42b9f90d9dfa1b19959456e175
Location: Product listing
Retrieved Sep 16, 2026
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by Panasonic. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Panasonic published. Original address: https://cdn.myced.com/images/Products/ZZ0000/ZZ2997/00000/ZZ299700049_DS.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: bee15c459848d448a85666bc0eed0b2bab098e42b9f90d9dfa1b19959456e175
No sourced accessories or replacement parts listed yet.
Manufacturer SKU EVPV410H
Observed Oct 11, 2026
Product / system scope unresolved. Model EVPV410H listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under PANASONIC CORPORATION OF NORTH AMERICA, as "EVPV410H", CEC listing date 2022-04-11. This is an equipment listing, not UL certification or complete-system approval.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: panels-0.4-personal documented pct: 5 basis: Unknown missing: Module efficiency needed Product warranty needed Power warranty needed Power temperature coefficient needed First-year degradation needed criteria: key: efficiency label: Module efficiency value: Unknown unit: Unknown shown: 22.2 % · not confirmed shown detail: Unknown state: unconfirmed points: 0 ceiling: 26 weight: 26 share: Unknown covered: no missing: yes folded: no reason: not-counted reason text: A value is on file but is not counted: it carries a warning or is not confirmed. note: Not documented. display note: Unknown Sources: [1] key: warranty label: Product warranty value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 21 weight: 21 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: performanceWarranty label: Power warranty value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: powerTemperature label: Power temperature coefficient value: Unknown unit: Unknown shown: -0.26 %/°C · not confirmed shown detail: Unknown state: unconfirmed points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: no reason: not-counted reason text: A value is on file but is not counted: it carries a warning or is not confirmed. note: Not documented. display note: Unknown Sources: [1] key: degradation label: First-year degradation value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: weightPerWatt label: Weight / watt value: 0.05 unit: Unknown shown: 20.5 kg / 410 W shown detail: Unknown state: documented points: 1.2 ceiling: 5 weight: 5 share: 24.5 covered: yes missing: no folded: no reason: documents-disagree reason text: The maker's documents disagree; the less favorable printed figure, 0.05 kg per W, is scored. Warning: Panasonic's installation manual and a distributor's listing differ for this field. note: 20.5 kg / 410 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel. display note: Unknown | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page