Charged ReviewsSaved 0Compare 0Login
Panasonic EVPV400HK
Panasonic
Solar panel

Panasonic EVPV400HK

Key specs

Rated power400 W
Weight20.5 kg / 45.2 lb converted Check note
Open-circuit voltage48.8 V
Short-circuit current10.4 A Check note
Voltage at max power41.4 V Check note
Current at max power9.67 A Check note

All specifications

Identity

BrandPanasonic · Website
ModelEVPV400HK
MarketUnknown
Manufacturer SKUEVPV400HK Provisional
SKU detail
locator: Part number
conditions: Seller-listed specification; not independently verified.
Sources: [1]
FieldValueConditionsSource
Current at max power9.67 A Check note
Panasonic documents print different values. Panasonic's datasheet RS23098DS-R2 prints 9.67 A, which is recorded; the datasheet is the primary source. An older Panasonic document printed 9.51 A.
Printed as "Maximum Power Current (lpm) 9.72A 9.67A" (the EVPV400HK column) in Panasonic's EverVolt datasheet RS23098DS-R2 for EVPV410HK and EVPV400HK, a Panasonic document hosted by its distributor CED Greentech. Corrected on 17 October 2026: the catalog had recorded 9.51 A from the archived document; that value stays listed as an alternative. Revised on 17 October 2026: Panasonic's datasheet prints 9.67 A for this exact model; the earlier 9.51 A rested only on an Internet Archive copy (PM, October 17, 2026).
Where: Datasheet RS23098DS-R2, Electrical/Mechanical Specifications, Maximum Power Current (Ipm), EVPV400HK column
Sources
9.51 A

Printed as "Maximum Power Current (Ipm) 10.68A 10.62A 10.58A 9.61A 9.51A 9.40A" in Table 2. EVPVXXXPK, EVPVXXXHK SERIES of Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022), whose header reads "Model EVPV370PK EVPV360PK EVPV350PK EVPV410HK EVPV400HK EVPV390HK"; EVPV400HK is the fifth column. Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C)). Revised on 1 October 2026: The installation manual, first in the owner's source order, prints a different value for this model than a distributor's listing recorded earlier; the recorded value is kept beside it.

[2]
9.67 A

Seller-listed specification; not independently verified.

[1]
[3]
Short-circuit current10.4 A Check note
Panasonic documents print different values. Panasonic's datasheet RS23098DS-R2 prints 10.4 A, which is recorded; the datasheet is the primary source. An older Panasonic document printed 10.28 A.
Printed as "Short Circuit Current (lsc) 10.42A 10.40A" (the EVPV400HK column) in Panasonic's EverVolt datasheet RS23098DS-R2 for EVPV410HK and EVPV400HK, a Panasonic document hosted by its distributor CED Greentech. Corrected on 17 October 2026: the catalog had recorded 10.28 A from the archived document; that value stays listed as an alternative. Revised on 17 October 2026: Panasonic's datasheet prints 10.4 A for this exact model; the earlier 10.28 A rested only on an Internet Archive copy (PM, October 17, 2026).
Where: Datasheet RS23098DS-R2, Electrical/Mechanical Specifications, Short Circuit Current (Isc), EVPV400HK column
Sources
10.28 A

Printed as "Short Circuit Current (Isc) 11.38A 11.26A 11.13A 10.35A 10.28A 10.22A" in Table 2. EVPVXXXPK, EVPVXXXHK SERIES of Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022), whose header reads "Model EVPV370PK EVPV360PK EVPV350PK EVPV410HK EVPV400HK EVPV390HK"; EVPV400HK is the fifth column. Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C)). Revised on 1 October 2026: The installation manual, first in the owner's source order, prints a different value for this model than a distributor's listing recorded earlier; the recorded value is kept beside it.

[2]
10.4 A

Seller-listed specification; not independently verified.

[1]
[3]
Voltage at max power41.4 V Check note
Panasonic documents print different values. Panasonic's datasheet RS23098DS-R2 prints 41.4 V, which is recorded; the datasheet is the primary source. An older Panasonic document printed 42.1 V.
Printed as "Maximum Power Voltage (Vpm) 42.2V 41.4V" (the EVPV400HK column) in Panasonic's EverVolt datasheet RS23098DS-R2 for EVPV410HK and EVPV400HK, a Panasonic document hosted by its distributor CED Greentech. Corrected on 17 October 2026: the catalog had recorded 42.1 V from the archived document; that value stays listed as an alternative. Revised on 17 October 2026: Panasonic's datasheet prints 41.4 V for this exact model; the earlier 42.1 V rested only on an Internet Archive copy (PM, October 17, 2026).
Where: Datasheet RS23098DS-R2, Electrical/Mechanical Specifications, Maximum Power Voltage (Vpm), EVPV400HK column
Sources
42.1 V

Printed as "Maximum Power Voltage (Vpm) 34.7V 33.9V 33.1V 42.7V 42.1V 41.5V" in Table 2. EVPVXXXPK, EVPVXXXHK SERIES of Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022), whose header reads "Model EVPV370PK EVPV360PK EVPV350PK EVPV410HK EVPV400HK EVPV390HK"; EVPV400HK is the fifth column. Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C)). Revised on 1 October 2026: The installation manual, first in the owner's source order, prints a different value for this model than a distributor's listing recorded earlier; the recorded value is kept beside it.

[2]
41.4 V

Seller-listed specification; not independently verified.

[1]
[3]
Open-circuit voltage48.8 V
Printed as "Open Circuit Voltage (Voc) 49.4V 48.8V" (the EVPV400HK column) in Panasonic's EverVolt datasheet RS23098DS-R2 for EVPV410HK and EVPV400HK, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026).
Where: Datasheet RS23098DS-R2, Electrical/Mechanical Specifications, Open Circuit Voltage (Voc), EVPV400HK column
[3] [1]
Cell typeSilicon hetero-junction Check note
Panasonic's installation manual and a distributor's listing differ for this field. Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022) prints Silicon hetero-junction for EVPV400HK; a distributor's listing recorded earlier gives Monocrystalline. The manual's value is shown first; the earlier value is kept below.
Read from rendered page 7: the Cell Type row of Table 2. EVPVXXXPK, EVPVXXXHK SERIES of Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022) prints "PERC" across the three PK columns and "Silicon hetero-junction" across the HK columns; the text layer reads "Cell Type PERC Silicon hetero-junction". Revised on 1 October 2026: The installation manual, first in the owner's source order, prints a different value for this model than a distributor's listing recorded earlier; the recorded value is kept beside it.
Where: PDF page 7, Table 2. EVPVXXXPK, EVPVXXXHK SERIES, Cell Type row
Sources
Monocrystalline

Seller-listed specification; not independently verified.

[1]
[2]
GroundingEVERVOLT® modules have a small round grounding hole positioned near each corner of the module on both the long side and the short side; Suitable grounding lugs must be used: Listed (KDER) ILSCO, GBL- 4DBT (tin plated) (E34440); Grounding cable size should be between 4 - 14 AWG (2.1 mm² - 21.2 mm²); Fix lug to the frame using a star washer and lock nut, ensuring a conductive connection
Printed as "EVERVOLT® modules have a small round grounding hole positioned near each corner of the module on both the long side and the short side", "Suitable grounding lugs must be used: Listed (KDER) ILSCO, GBL- 4DBT (tin plated) (E34440)", "Grounding cable size should be between 4 - 14 AWG (2.1 mm² - 21.2 mm²)" and "Fix lug to the frame using a star washer and lock nut, ensuring a conductive connection" under Earth Ground Wiring in Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022); statements for all the EVERVOLT series it covers.
Where: PDF page 22, Earth Ground Wiring
[2]
Weight20.5 kg / 45.2 lb converted Check note
Panasonic's installation manual and a distributor's listing differ for this field. Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022) prints 20.5 kg for EVPV400HK; a distributor's listing recorded earlier gives 20.41 kg. The manual's value is shown first; the earlier value is kept below.
Printed as "Weight 45.0 lbs (20.5kg)" in Panasonic's EverVolt datasheet RS23098DS-R2 for EVPV410HK and EVPV400HK, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026).
Where: Datasheet RS23098DS-R2, Electrical/Mechanical Specifications, Weight
Sources
20.41 kg

Printed as "Weight 45 Lbs." in the Panasonic EverVolt 400W 132 Half-Cell HJT 1000V BLK/BLK Solar Panel, EVPV400HK; the maker prints pounds only, converted to kilograms. Revised on 30 September 2026: The maker prints this weight in pounds only; the stored kilograms were an unlabeled conversion, now labeled with the printed pounds kept (Project Manager, September 30, 2026).

[1]
[3]
Clamp torque8.8 to 18.4 ft-lb
Printed as "EVERVOLT® modules must be secured with a torque between 8.8-18.4 ft- lb (12 - 25 Nm)." under Use of Rails and Clamps in Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022) (the first printed unit is "ft- lb", with "12 - 25 Nm" in parentheses); the same sentence is printed for mounting holes on PDF page 20. A statement for all the EVERVOLT series it covers.
Where: PDF page 10, Use of Rails and Clamps
[2]
DimensionsW 1,016 × L 1,821 × D 30 mm / W 40 × L 71.69 × D 1.2 in converted Check note
Panasonic's installation manual and a distributor's listing differ for this field. Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022) prints 1821 x 1016 x 30 mm for EVPV400HK; a distributor's listing recorded earlier gives 1721 x 1016 x 30 mm. The manual's value is shown first; the earlier value is kept below.
Printed as "Dimensions LxWxH 71.7 x 40.0 x 1.2 in (1821 x 1016 x 30 mm)" in Panasonic's EverVolt datasheet RS23098DS-R2 for EVPV410HK and EVPV400HK, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026).
Where: Datasheet RS23098DS-R2, Electrical/Mechanical Specifications, Dimensions LxWxH
Sources
W 1,016 × L 1,721 × D 30 mm

Seller-listed specification; not independently verified.

[1]
[3]
Rated power400 W
Printed as "Rated Power (Pmax)¹ 410W 400W" (the EVPV400HK column) in Panasonic's EverVolt datasheet RS23098DS-R2 for EVPV410HK and EVPV400HK, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026).
Where: Datasheet RS23098DS-R2, Electrical/Mechanical Specifications, Rated Power (Pmax), EVPV400HK column
[3] [1]
Series fuse25 A ProvisionalSeller-listed specification; not independently verified.
Where: series-fuse-rating
[1]
Mounting methodsInstalling the EVERVOLT® modules with clamps and rails has been found to comply with UL 61730 requirements for downward pressure, e.g., snow, of up to 7000 Pa (4666 Pa design load*) and upward pressure, e.g., wind, of up to 4000 Pa (2666 Pa design load*); The module must be secured, e.g., clamped, at least once in each of the four marked zones shown below (Figure. 8).; MOUNTING EVPVXXXH AND EVPVXXXHK SERIES MODULES WITH CONTINOUS RAILS PARALLEL TO SHORT SIDE OF THE MODULE; MOUNTING EVPVXXXH AND EVPVXXXHK SERIES MODULES WITH CONTINOUS RAILS PARALLEL TO LONG SIDE OF THE MODULE; MOUNTING EVPVXXXH AND EVPVXXXHK SERIES MODULES WITH SHORT RAILS; Installing the EVERVOLT® modules using the mounting holes has been found to comply with UL 61730 requirements for downward pressure,e.g., snow, of up to 5400 Pa (3600 Pa design load*) and upward pressure,e.g., wind, of up to 2400 Pa (1600 Pa design load*); All four mounting holes in the frame must be used (Figure 21).
Printed as "Installing the EVERVOLT® modules with clamps and rails has been found to comply with UL 61730 requirements for downward pressure, e.g., snow, of up to 7000 Pa (4666 Pa design load*) and upward pressure, e.g., wind, of up to 4000 Pa (2666 Pa design load*)" (PDF page 10) and "Installing the EVERVOLT® modules using the mounting holes has been found to comply with UL 61730 requirements for downward pressure" (PDF page 20, with the loads quoted in the value) in Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022). The clamping-zone tables for this series (PDF pages 14 to 16) give separate test and design loads for each clamping zone and clearance gap, and say "If the panel is secured in zones with different load values, it is rated to the lowest load value only." Loads vary by mounting method, zone and gap, so no single front or rear load is recorded.
Where: PDF page 10, Use of Rails and Clamps; PDF pages 14 to 16, clamping tables; PDF page 20, Mounting Holes
[2]
Cable bend radiusThe cables must have a minimum bending radius of 1.2 in (30 mm) to avoid damage to the insulation
Printed as "The cables must have a minimum bending radius of 1.2 in (30 mm) to avoid damage to the insulation" under Cable Management in Panasonic's EVERVOLT General Installation Manual (Revision C, 11.15.2022), a statement for all the EVERVOLT series it covers.
Where: PDF page 9, Cable Management
[2]
Max series fuse25 A
Printed as "Maximum Series Fuse 25 A" in Panasonic's EverVolt datasheet RS23098DS-R2 for EVPV410HK and EVPV400HK, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026).
Where: Datasheet RS23098DS-R2, Electrical/Mechanical Specifications, Maximum Series Fuse
[3]
Max system voltage1,000 V
Printed as "Maximum System Voltage 1000V" in Panasonic's EverVolt datasheet RS23098DS-R2 for EVPV410HK and EVPV400HK, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026).
Where: Datasheet RS23098DS-R2, Electrical/Mechanical Specifications, Maximum System Voltage
[3] [1]
Module efficiency21.6 % ProvisionalSeller-listed specification; not independently verified.
Where: efficiency
[1]
Operating temperature-40 to 85 °C / -40 to 185 °F converted
Printed as "Operating Temperature -40ºF to 185ºF (-40ºC to 85ºC)" in Panasonic's EverVolt datasheet RS23098DS-R2 for EVPV410HK and EVPV400HK, a Panasonic document hosted by its distributor CED Greentech. Revised on 17 October 2026: The fact rested on an Internet Archive copy (with, at most, a distributor's product page); Panasonic's datasheet as hosted by its distributor CED Greentech (distributor copy, not verified against Panasonic's file) prints the same value for this exact model, so the fact is re-cited to it (PM, October 17, 2026).
Where: Datasheet RS23098DS-R2, Electrical/Mechanical Specifications, Operating Temperature
[3]
Temperature coefficient-0.26 %/°C ProvisionalSeller-listed specification; not independently verified.
Where: temp-coefficient-pmpp
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Rated output
400 WEfficiency 21.6 %W / sq ft 20.1* (Calculated: 400 W ÷ (1,821 mm × 1,016 mm = 19.91 sq ft) = 20.1 W/sq ft)
Voltage (STC)
41.4 VNeeds confirmationVmp · maximum powerVoc · open circuit 48.8 VMax system 1,000 V
Current (STC)
9.67 ANeeds confirmationImp · maximum powerIsc · short circuit 10.4 ANeeds confirmation
Dimensions
D: 30 × W: 1,016 × L: 1,821 mm / D: 1.2 × W: 40 × L: 71.69 inWeight 20.5 kg / 45.2 lb
Warranty
Not statedPower warranty Not stated

Evidence score

1/1005% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Module efficiency needed; Product warranty needed; Power warranty needed; Power temperature coefficient needed; First-year degradation needed.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Module efficiency21.6 % · not confirmed0.0 / 26.0

Seller-listed specification; not independently verified.

A value is on file but is not counted: it carries a warning or is not confirmed.

[1]

Power temperature coefficient-0.26 %/°C · not confirmed0.0 / 16.0

Seller-listed specification; not independently verified.

A value is on file but is not counted: it carries a warning or is not confirmed.

[1]

Weight / watt20.5 kg / 400 W1.2 / 5.0

0.05125 kg per W is the less favorable figure the maker's documents print, and it is scored because they disagree; it never sets or raises the bar. The bar is 0.01227 kg per W, the lowest documented for a solar panel, calculated from maker figures: Go Power! 110-Watt Solar Flex™ Module

20.5 kg / 400 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.

The maker's documents disagree; the less favorable printed figure, 0.05125 kg per W, is scored. Warning: Panasonic's installation manual and a distributor's listing differ for this field.

[3] [1]

Not documented, 0 points: Product warranty, Power warranty, First-year degradation.

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
CECauthority listing reportedlisted as of snapshot[4]
Scope
equipment listing
Covered models
EVPV400HK
Limitations
Model EVPV400HK listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under PANASONIC CORPORATION OF NORTH AMERICA, as "EVPV400HK", CEC listing date 2023-03-13. This is an equipment listing, not UL certification or complete-system approval.
Record detail
Issued: Not stated
Valid from: Mar 13, 2023
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[4]

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Panasonic EVERVOLT General Installation Manual, EVPVXXX, EVPVXXXK, EVPVXXXH, EVPVXXXPK and EVPVXXXHK series (Revision C, 11.15.2022; Internet Archive copy captured 15 July 2024)Panasonic · Source installation manual · November 2022 · PDF
    Source details
    Revision
    Revision C
    Revision date
    November 2022

    Internet Archive copy dated July 15, 2024 (the archive's own date); read on October 1, 2026.

    Location: Cover page (series) and PDF pages 6 and 7 (Tables 1 and 2)

    Retrieved Oct 1, 2026

    Panasonic's own installation manual for its EVERVOLT modules, originally at https://ftp.panasonic.com/solar/installation/evervolt_solar_k_install.pdf, which Panasonic's solar support page links as the "EVPVxxx, EVPVxxxK Modules Installation Manual"; the archived file is Revision C of 11.15.2022, whose cover names the EVPVXXX, EVPVXXXK, EVPVXXXH, EVPVXXXPK and EVPVXXXHK series. Tables 1 and 2 print per-model ratings for EVPV410H, 400H, 390H, 380, 370, 360, 370K, 360K, 370PK, 360PK, 350PK, 410HK, 400HK and 390HK; it does not cover the HK2 models. North American edition (UL 61730, NEC). Series-level instruction otherwise. Panasonic's own host ftp.panasonic.com disallows all robots, so this is an archived copy: the Internet Archive captured Panasonic's own file on 15 July 2024, and that archived copy was read on 1 October 2026. It is labeled as an archived copy, not a current download from Panasonic. Manufacturer instructions, not independent tests.

    Open
  • Datasheets

  • ViewPanasonic · Distributor datasheet · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Linked from the GreenTech Renewables product page with link text "View".

    Location: ZZ299700056_DS.pdf

    Retrieved Sep 18, 2026

    Original PDF preserved byte for byte, found linked from the GreenTech Renewables listing https://www.greentechrenewables.com/product/panasonic-evervolt-400w-132-half-cell-hjt-1000v-blkblk-solar-panel-evpv400hk. The revision is whatever was published at this URL on the access date; exact variant coverage inside the document was not separately verified and no later revision was checked.

    SHA-256: 799dea61d9345ff6ebeca6c1aed4a1cc822f612943f3156e31196e2432b3b63e

    Archived copies

    Archived copy of a document published by Panasonic. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.53 MB

    Archived copy, unaltered, kept as a record of what Panasonic published. Original address: https://cdn.myced.com/images/Products/ZZ0000/ZZ2997/00000/ZZ299700056_DS.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    None

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 799dea61d9345ff6ebeca6c1aed4a1cc822f612943f3156e31196e2432b3b63e

    Open
  • Other documents

  • Panasonic EverVolt 400W 132 Half-Cell HJT 1000V BLK/BLK Solar Panel, EVPV400HKGreentech Renewables · Distributor product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Product listing

    Retrieved Sep 16, 2026

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

EVPV400HK · Datasheet

Archived copy of a document published by Panasonic. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.53 MB

Archived copy, unaltered, kept as a record of what Panasonic published. Original address: https://cdn.myced.com/images/Products/ZZ0000/ZZ2997/00000/ZZ299700056_DS.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 799dea61d9345ff6ebeca6c1aed4a1cc822f612943f3156e31196e2432b3b63e

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
EVPV400HK

Manufacturer SKU EVPV400HK

  1. Observed Oct 11, 2026

    CEC: claimed

    Product / system scope unresolved. Model EVPV400HK listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under PANASONIC CORPORATION OF NORTH AMERICA, as "EVPV400HK", CEC listing date 2023-03-13. This is an equipment listing, not UL certification or complete-system approval.

    [4]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: panels-0.4-personal
documented pct: 5
basis: Unknown
missing:
Module efficiency needed
Product warranty needed
Power warranty needed
Power temperature coefficient needed
First-year degradation needed
criteria:
key: efficiency
label: Module efficiency
value: Unknown
unit: Unknown
shown: 21.6 % · not confirmed
shown detail: Unknown
state: unconfirmed
points: 0
ceiling: 26
weight: 26
share: Unknown
covered: no
missing: yes
folded: no
reason: not-counted
reason text: A value is on file but is not counted: it carries a warning or is not confirmed.
note: Not documented.
display note: Unknown
Sources: [1]
key: warranty
label: Product warranty
value: Unknown
unit: Unknown
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 21
weight: 21
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: performanceWarranty
label: Power warranty
value: Unknown
unit: Unknown
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 16
weight: 16
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: powerTemperature
label: Power temperature coefficient
value: Unknown
unit: Unknown
shown: -0.26 %/°C · not confirmed
shown detail: Unknown
state: unconfirmed
points: 0
ceiling: 16
weight: 16
share: Unknown
covered: no
missing: yes
folded: no
reason: not-counted
reason text: A value is on file but is not counted: it carries a warning or is not confirmed.
note: Not documented.
display note: Unknown
Sources: [1]
key: degradation
label: First-year degradation
value: Unknown
unit: Unknown
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 16
weight: 16
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: weightPerWatt
label: Weight / watt
value: 0.0512
unit: Unknown
shown: 20.5 kg / 400 W
shown detail: Unknown
state: documented
points: 1.2
ceiling: 5
weight: 5
share: 23.9
covered: yes
missing: no
folded: no
reason: documents-disagree
reason text: The maker's documents disagree; the less favorable printed figure, 0.05125 kg per W, is scored. Warning: Panasonic's installation manual and a distributor's listing differ for this field.
note: 20.5 kg / 400 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.
display note: Unknown
Sources: [3] [1]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Panasonic EverVolt 400W 132 Half-Cell HJT 1000V BLK/BLK Solar Panel, EVPV400HK (Greentech Renewables · seller · observed Sep 16, 2026)
  2. Panasonic EVERVOLT General Installation Manual, EVPVXXX, EVPVXXXK, EVPVXXXH, EVPVXXXPK and EVPVXXXHK series (Revision C, 11.15.2022; Internet Archive copy captured 15 July 2024) (Panasonic · archive · Revision C · observed Oct 1, 2026)
  3. View (Panasonic · manufacturer document distributor hosted · observed Sep 18, 2026)
  4. CEC PV Module List, official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)

Sign in to report an error on this page