Printed as "Frame Black anodized aluminum" in Meyer Burger Black datasheet MB_B120AyB_XXX (Version Q2_2024_V7_UL_en_us), captured on September 28, 2026.
Printed as "390 21.2 294 390 8.5 10.6 42.4 44.6 8.0 10.1 36.7 38.9" in Meyer Burger Black US datasheet, product type MB_B120AyB_XXX, version Q2_2024_V7_UL_en_us (Internet Archive copy of the meyerburger.com file), Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Electrical specification table, power class 390 row, Current Impp STC column. Revised on 1 October 2026: The datasheet prints this current at maximum power for power class 390 in the electrical specification table on page 2, not page 1.
Where: Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Electrical specification table, power class 390 row, Current Impp STC column
Printed as "390 21.2 294 390 8.5 10.6 42.4 44.6 8.0 10.1 36.7 38.9" in Meyer Burger Black US datasheet, product type MB_B120AyB_XXX, version Q2_2024_V7_UL_en_us (Internet Archive copy of the meyerburger.com file), Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Electrical specification table, power class 390 row, Short circuit current Isc STC column. Revised on 1 October 2026: The datasheet prints this short circuit current for power class 390 in the electrical specification table on page 2, not page 1.
Where: Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Electrical specification table, power class 390 row, Short circuit current Isc STC column
Printed as "390 21.2 294 390 8.5 10.6 42.4 44.6 8.0 10.1 36.7 38.9" in Meyer Burger Black US datasheet, product type MB_B120AyB_XXX, version Q2_2024_V7_UL_en_us (Internet Archive copy of the meyerburger.com file), Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Electrical specification table, power class 390 row, Voltage Vmpp STC column. Revised on 1 October 2026: The datasheet prints this voltage at maximum power for power class 390 in the electrical specification table on page 2, not page 1.
Where: Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Electrical specification table, power class 390 row, Voltage Vmpp STC column
Printed as "390 21.2 294 390 8.5 10.6 42.4 44.6 8.0 10.1 36.7 38.9" in Meyer Burger Black US datasheet, product type MB_B120AyB_XXX, version Q2_2024_V7_UL_en_us (Internet Archive copy of the meyerburger.com file), Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Electrical specification table, power class 390 row, Open circuit voltage Voc STC column. Revised on 1 October 2026: The datasheet prints this open circuit voltage for power class 390 in the electrical specification table on page 2, not page 1.
Where: Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Electrical specification table, power class 390 row, Open circuit voltage Voc STC column
Datasheet prints "Solar cell type 120 half-cells, mono n-Si, HJT with SWCT® bifacial cell technology". Covers the Black series MB-B120AyB-XXX range, which includes this model.
Printed as "Solar cell type 120 half-cells, mono n-Si, HJT with SWCT" in Meyer Burger Black US datasheet, product type MB_B120AyB_XXX, version Q2_2024_V7_UL_en_us (Internet Archive copy of the meyerburger.com file), Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Mechanical specification, "Solar cell type" row. Revised on 1 October 2026: The datasheet prints the HJT cell type in the mechanical specification on page 2, not page 1.
Where: Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Mechanical specification, "Solar cell type" row
There are grounding holes on the module frames for connecting the PV module grounding and these are marked as such.; Recommended mounting type for grounding connection: M4 screw, washer, serrated washer, grounding cable lug, washer, washer, M4 nut; Ø4.5 (8x) Grounding holes Check note
From the international edition; the North American edition may differ. The value comes from Meyer Burger's installation and operating manual 1-0-1 (Revision 2.1, December 2022), which says it is valid in Africa, Asia, Europe, Latin America and South America. This record is the North American (UL) model, and a North American edition of the manual, which was not found, may print a different value.
Printed as "There are grounding holes on the module frames for connecting the PV module grounding and these are marked as such." in section 2.9 of Meyer Burger's installation and operating manual 1-0-1, international edition (Revision 2.1, December 2022), which adds that the module grounding must follow national, regional and local rules. The hardware list is the labels of the figure "Recommended mounting type for grounding connection" on the same page, in the order printed, and the eight 4.5 mm grounding holes are from the MEYER BURGER BLACK/WHITE dimension drawing on PDF page 4 (checked on rendered pages 4 and 6).
Where: PDF page 6, section 2.9 Equipotential bonding, grounding and lightning protection, and PDF page 4 (dimension drawings)
Printed as "Weight [kg / lbs] 19.7 / 43.4" in Meyer Burger Black US datasheet, product type MB_B120AyB_XXX, version Q2_2024_V7_UL_en_us (Internet Archive copy of the meyerburger.com file), Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Mechanical specification, "Weight" row. Revised on 1 October 2026: The datasheet prints this weight in the mechanical specification on page 2, not page 1.
Where: Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Mechanical specification, "Weight" row
Tempered solar glass, 3.2 mm / 0.13 in, with anti-reflective surface
Printed as "Front cover Tempered solar glass, 3.2 mm / 0.13 in, with anti-reflective surface" in Meyer Burger Black datasheet MB_B120AyB_XXX (Version Q2_2024_V7_UL_en_us), captured on September 28, 2026.
Where: Datasheet page 2, Mechanical specification, Front cover row
A maximum torque of 20 Nm must not be exceeded. N·m Check note
From the international edition; the North American edition may differ. The value comes from Meyer Burger's installation and operating manual 1-0-1 (Revision 2.1, December 2022), which says it is valid in Africa, Asia, Europe, Latin America and South America. This record is the North American (UL) model, and a North American edition of the manual, which was not found, may print a different value.
Printed as "A maximum torque of 20 Nm must not be exceeded." in section 3.6 Clamping system of Meyer Burger's installation and operating manual 1-0-1, international edition (Revision 2.1, December 2022), after "Clamps must be attached to the substructure as specified by the substructure manufacturer, including specific hardware and torque requirements." A maximum, kept as printed text.
Printed as "Back cover Black water-barrier backsheet" in Meyer Burger Black datasheet MB_B120AyB_XXX (Version Q2_2024_V7_UL_en_us), captured on September 28, 2026.
Where: Datasheet page 2, Mechanical specification, Back cover row
W 1,041 × L 1,767 × D 35 mm / W 40.98 × L 69.57 × D 1.4 in converted
Printed as "Dimensions [mm / in] 1767 x 1041 x 35 / 69.6 x 41.0 x 1.4" in Meyer Burger Black US datasheet, product type MB_B120AyB_XXX, version Q2_2024_V7_UL_en_us (Internet Archive copy of the meyerburger.com file), Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Mechanical specification, "Dimensions" row. Revised on 1 October 2026: The datasheet prints these dimensions in the mechanical specification on page 2, not page 1.
Where: Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Mechanical specification, "Dimensions" row
Printed as "390 21.2 294 390 8.5 10.6 42.4 44.6 8.0 10.1 36.7 38.9" in Meyer Burger Black US datasheet, product type MB_B120AyB_XXX, version Q2_2024_V7_UL_en_us (Internet Archive copy of the meyerburger.com file), Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Electrical specification table, power class 390 row, Power Pmax STC column. Revised on 1 October 2026: The datasheet prints this rated power for power class 390 in the electrical specification table on page 2, not page 1.
Where: Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Electrical specification table, power class 390 row, Power Pmax STC column
Printed as "Overcurrent protection rating [A] 20" in Meyer Burger Black US datasheet, product type MB_B120AyB_XXX, version Q2_2024_V7_UL_en_us (Internet Archive copy of the meyerburger.com file), Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Properties for system design, "Overcurrent protection rating" row. Revised on 1 October 2026: The datasheet prints this overcurrent protection rating under properties for system design on page 2, not page 1.
Where: Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Properties for system design, "Overcurrent protection rating" row
From the international edition; the North American edition may differ. The value comes from Meyer Burger's installation and operating manual 1-0-1 (Revision 2.1, December 2022), which says it is valid in Africa, Asia, Europe, Latin America and South America. This record is the North American (UL) model, and a North American edition of the manual, which was not found, may print a different value.
Printed as "1200 Cable length" in the MEYER BURGER BLACK/WHITE dimension drawing ("Dimensions in mm") on PDF page 4 of Meyer Burger's installation and operating manual 1-0-1, international edition (Revision 2.1, December 2022); the drawing labels were checked on rendered page 4.
Clamps: minimum clamping width 40 mm, clamping height for 35 mm frame height, clamping depth 7–11 mm; CP1, four module clamps on the long module side with continuous substructure rails: L 320 mm, design load 4000 Pa pressure / 2666 Pa suction; L 200 - 450 mm, 3600 / 1600 Pa; L 0 - 550 mm, 1600 / 1600 Pa; CP1a, four module clamps on the long module side without continuous substructure rails: L 200 - 450 mm, 3200 / 1600 Pa; L 0 - 550 mm, 1600 / 1600 Pa; CP2, four module clamps on the short module side with continuous substructure rails: W 160 - 210 mm, 1600 / 1600 Pa; CP2a, four module clamps on the short module side without continuous substructure rails: W 0 - 300 mm, 1600 / 1600 Pa; CL1, clamps on the long module side, line mounting along the long module side: L 320 mm, 3600 / 2666 Pa; L 200 - 450 mm, 3600 / 1600 Pa; L 0 - 550 mm, 1600 / 1600 Pa; CL2, clamps on the short module side, line mounting along the short module side: W 0 - 300 mm, 1600 / 1600 Pa; IP1, insert profile rails on the long module side: 3600 / 2666 Pa; IP2, insert profile rails on the short module side: 1600 / 1600 Pa; MP1, mounting points on the long module side with continuous substructure rails: L 320 mm, 4000 / 2666 Pa; MP1a, mounting points on the long module side, line mounting along the long module side: L 320 mm, 3600 / 1600 Pa Check note
From the international edition; the North American edition may differ. The value comes from Meyer Burger's installation and operating manual 1-0-1 (Revision 2.1, December 2022), which says it is valid in Africa, Asia, Europe, Latin America and South America. This record is the North American (UL) model, and a North American edition of the manual, which was not found, may print a different value.
Printed as "x x x CP1 320 4000 2666 6000 4000 200 - 450 3600 1600 5400 2400 0 - 550 1600 1600 2400 2400" (and the other rows quoted) in the overview table of section 3.7 Installation types of Meyer Burger's installation and operating manual 1-0-1, international edition (Revision 2.1, December 2022); each row marks the module lines it applies to (WHITE, BLACK, GLASS), and the MP1 and MP1a rows are marked for WHITE and BLACK only. The loads in the value are the design loads (pressure / suction); the table also prints test loads with a 1.5x safety factor (for example 6000 / 4000 Pa for CP1 at L 320 mm). L and W are the clamp positions measured as in the sketches of the per-type tables. Table layout checked on rendered page 10. The clamp requirements are from section 3.6, which also says "Suitable fastening variants can be developed in consultation with MBI for assembly with unspecified installation types or with increased loads."
Where: PDF page 9 (section 3.6 Clamping system), PDF page 10 (section 3.7 Installation types, overview table) and PDF pages 11 to 15 (one table per installation type)
Printed as "Max. system voltage [V] 1000" in Meyer Burger Black US datasheet, product type MB_B120AyB_XXX, version Q2_2024_V7_UL_en_us (Internet Archive copy of the meyerburger.com file), Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Properties for system design, "Max. system voltage" row. Revised on 1 October 2026: The datasheet prints this maximum system voltage under properties for system design on page 2, not page 1.
Where: Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Properties for system design, "Max. system voltage" row
Printed as "390 21.2 294 390 8.5 10.6 42.4 44.6 8.0 10.1 36.7 38.9" in Meyer Burger Black US datasheet, product type MB_B120AyB_XXX, version Q2_2024_V7_UL_en_us (Internet Archive copy of the meyerburger.com file), Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Electrical specification table, power class 390 row, Efficiency η STC column. Revised on 1 October 2026: The datasheet prints this efficiency for power class 390 in the electrical specification table on page 2, not page 1.
Where: Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Electrical specification table, power class 390 row, Efficiency η STC column
From the international edition; the North American edition may differ. The value comes from Meyer Burger's installation and operating manual 1-0-1 (Revision 2.1, December 2022), which says it is valid in Africa, Asia, Europe, Latin America and South America. This record is the North American (UL) model, and a North American edition of the manual, which was not found, may print a different value.
Printed as "Module operating temperature -40 °C to +85 °C" in section 2.1 Scope of application of Meyer Burger's installation and operating manual 1-0-1, international edition (Revision 2.1, December 2022), a statement for the modules the manual covers; the same list prints "Operating ambient temperature -40 °C to +45 °C".
Where: PDF page 4, section 2.1 Scope of application
Printed as "Temperature coefficient of PMPP γ [%/K] -0.259" in Meyer Burger Black US datasheet, product type MB_B120AyB_XXX, version Q2_2024_V7_UL_en_us (Internet Archive copy of the meyerburger.com file), Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Temperature coefficients, "Temperature coefficient of PMPP" row. Revised on 1 October 2026: The datasheet prints -0.259 %/K on page 2; a kelvin step equals a degree Celsius step, so the figure is the same in %/°C.
Where: Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Temperature coefficients, "Temperature coefficient of PMPP" row
Sources
Converted: -0.259 %/K x 1 (a change of 1 K equals a change of 1 °C)
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Product warranty needed; Power warranty needed; First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Printed as "390 21.2 294 390 8.5 10.6 42.4 44.6 8.0 10.1 36.7 38.9" in Meyer Burger Black US datasheet, product type MB_B120AyB_XXX, version Q2_2024_V7_UL_en_us (Internet Archive copy of the meyerburger.com file), Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Electrical specification table, power class 390 row, Efficiency η STC column. Revised on 1 October 2026: The datasheet prints this efficiency for power class 390 in the electrical specification table on page 2, not page 1.
Power temperature coefficient-0.26 %/°C13.6 / 16.0
0.259 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed as "Temperature coefficient of PMPP γ [%/K] -0.259" in Meyer Burger Black US datasheet, product type MB_B120AyB_XXX, version Q2_2024_V7_UL_en_us (Internet Archive copy of the meyerburger.com file), Meyer Burger Black US datasheet (Q2_2024_V7_UL_en_us), page 2, Temperature coefficients, "Temperature coefficient of PMPP" row. Revised on 1 October 2026: The datasheet prints -0.259 %/K on page 2; a kelvin step equals a degree Celsius step, so the figure is the same in %/°C.
Internet Archive copy of Meyer Burger's file (capture of 30 September 2023), obtained by Alternative Research on 1 October 2026.
Location: PDF page 1 (cover, modules covered) and PDF page 3 (section 1.2, where it is valid)
Retrieved Oct 1, 2026
Meyer Burger's own installation and operating manual for its MEYER BURGER BLACK, MEYER BURGER WHITE and MEYER BURGER GLASS modules (cover: "Valid for the following Meyer Burger photovoltaic modules"), originally at https://www.meyerburger.com/fileadmin/user_upload/PDFs/InstallationGuide/Meyer-Burger_1-0-1_installationguide_en.pdf. The last page prints "As of: December 2022 Revision number: 2.1". Section 1.2 says the manual is valid in Africa, Asia, Europe, Latin America and South America, so it is the international edition, not a North American one. Meyer Burger's own site could not be read with our research agent because its robots.txt could not be read (certificate error), so this copy was obtained by Alternative Research on 1 October 2026 from the Internet Archive, which captured Meyer Burger's own file on 30 September 2023. It is labeled as an archived copy, not a current download from Meyer Burger. Series-level instructions and load tables, not model ratings (the manual refers to the data sheets for those). Manufacturer instructions, not independent tests.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Page 1, Electrical specification, Mechanical specification, Properties for system design and Temperature coefficients
Retrieved Sep 25, 2026
Internet Archive copy, captured on September 18, 2025, of the datasheet Meyer Burger published at https://www.meyerburger.com/fileadmin/user_upload/PDFs/Produktdatenblaetter/US/Meyer-Burger_Black_Datasheet_MB_B120AyB_XXX_UL_EN_V07.pdf (last modified August 27, 2024 according to the archived response). meyerburger.com no longer serves its site: on September 25, 2026 the host answered HTTPS with a default server certificate and HTTP with "404 page not found", so the live file could not be read. The datasheet covers product type MB_B120AyB_XXX, where it prints "XXX = power class, y = connector type"; each power class has its own row in the electrical table. It states "All data and specifications are preliminary and subject to change without notice."
Archived copies
Archived copy of a document published by Meyer Burger. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
PDF
ViewOfficial · cdn.myced.com · Official datasheet · PDFSource details
Revision
Not stated
Revision date
Not stated
Linked from the GreenTech Renewables product page with link text "View".
Location: ZZ306200001_DS.pdf
Retrieved Sep 18, 2026
Original PDF preserved byte for byte, found linked from the GreenTech Renewables listing https://www.greentechrenewables.com/product/meyer-burger-375w-hjt-120-half-cell-1000v-blkblk-solar-panel-mb-b120ayb-375. The revision is whatever was published at this URL on the access date; exact variant coverage inside the document was not separately verified and no later revision was checked.
Archived copy of a document published by cdn.myced.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by cdn.myced.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Meyer Burger Black US datasheet, product type MB_B120AyB_XXX, version Q2_2024_V7_UL_en_us (Internet Archive copy of the meyerburger.com file)
Archived copy of a document published by Meyer Burger. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].