Charged Reviews · Quick reference
Maxeon Solar Technologies SPR-MAX6-415-BLK
- Brand
- Maxeon Solar Technologies
- Model
- SPR-MAX6-415-BLK
- SKU / part number
- SPR-MAX6-415-BLK[1]
- Category
- Solar panels

Electrical at STC
| Rated output (STC) | 415 W[1, 4, 6] |
|---|---|
| Module efficiency | 21.5 %[1, 4] |
| Voltage at max power (Vmp) | 39.8 V[1, 4, 6] |
| Current at max power (Imp) | 10.43 A[1, 4, 6] |
| Open-circuit voltage (Voc) | 48.1 V[1, 4, 6] |
| Short-circuit current (Isc) | 11.29 A[1, 4, 6] |
| Power tolerance | ? |
Temperature and system limits
| Temperature coefficient, Pmax | -0.29 %/°C[1, 4, 6] |
|---|---|
| Temperature coefficient, Voc | -0.24 %/°C[4, 6] |
| Temperature coefficient, Isc | 0.06 %/°C[4, 6] |
| Maximum system voltage | 1,000 V[1, 4, 6] |
| Maximum series fuse | 20 A[6] |
| NOCT / NMOT | ? |
| Rated output at NMOT | ? |
| Operating temperature | -40 to 85 °C[4] |
Cells and construction
| Cell technology | Monocrystalline[1, 4] |
|---|---|
| Cell count | 66 cells[4] |
| Bifacial | ? |
| Bifaciality | ? |
| Frame | Class 1 black anodized[4] |
| Front glass | ? |
| Rear surface | ? |
| Panel format | rigid[4] |
Mechanical and connections
| Dimensions | 40 D × 1,032 W × 1,872 L mm[1, 4] |
|---|---|
| Weight | 20.9 kg / 46.08 lb[4] |
| Connectors | EVO2[4] |
| Cable length | ? |
| Junction box rating | ? |
| Mounting | ? |
| Design load, front | ? |
| Design load, rear | ? |
Installation (from the manual)
Torque
| Clamp or bolt torque | torque should never exceed 11 ft-lbs (15 Nm)[6] |
|---|
Conductors
| Cable bending radius / connector notes | Maxeon recommends a conservative minimum bending radius (R) 5x cable diameter must be maintained and must not be bent on the direct exit of the connector or junction box.[6] |
|---|
Clearances and orientation
| Mounting methods and clamp zones | MAX6 66 cells with frame Gen 5.2 using Invisimount; no-hole mounting system has been evaluated to a wind and snow design load of 2873 Pa with clamp-mount method (End-mount method) and 1916 Pa with Quarter-mount method, with a safety factor of 1.5 minimum.; MAX6 72/66 cells with frame Gen 5.2 have been evaluated to a wind design load of 3600 Pa and snow design load of 6000 Pa with direct Quarter-mount method using mounting holes on the PV module, with a safety factor of 1.5 minimum.; MAX6 72/66 cells with frame Gen 5.6 have been evaluated to a wind design load of 3000 Pa and snow design load of 6000 Pa with direct Quarter-mount method using mounting holes on the PV module, with a safety factor of 1.5 minimum.; Modules are to be mounted to the Rail using the clamps located on the longer side, 50mm to 400mm from short edge of the module in portrait orientation;[6] |
|---|
Grounding
| Grounding | Attach a lay-in lug (Ilsco GBL-4DBT) to one of the grounding holes on the module frame, and attach the ground conductor to the lug.; Use an external-tooth star washer between the lug and the module frame in order to pierce the anodizing and establish electrical contact with the aluminum frame.; The assembly must end with a nut that’s torqued to 1.67–2.08 ft-lbs (for a #10-32 bolt).[6] |
|---|
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.