Charged Reviews · Quick reference
Maxeon Solar Technologies SPR-MAX6-415-BLK
- Brand
- Maxeon Solar Technologies
- Model
- SPR-MAX6-415-BLK
- SKU / part number
- SPR-MAX6-415-BLK Provisional [1]
- Category
- Solar panels
chargedreviews.com/panels/maxeon-solar-technologies-spr-max6-415-blk
Electrical at STC
- Power tolerance
- ?
Temperature and system limits
Cells and construction
Mechanical and connections
Installation (from the manual)
Torque
- Clamp or bolt torque
- torque should never exceed 11 ft-lbs (15 Nm) ft-lb [2]
Conductors
- Cable bending radius / connector notes
- Maxeon recommends a conservative minimum bending radius (R) 5x cable diameter must be maintained and must not be bent on the direct exit of the connector or junction box. [2]
Clearances and orientation
- Mounting methods and clamp zones
- MAX6 66 cells with frame Gen 5.2 using Invisimount; no-hole mounting system has been evaluated to a wind and snow design load of 2873 Pa with clamp-mount method (End-mount method) and 1916 Pa with Quarter-mount method, with a safety factor of 1.5 minimum.; MAX6 72/66 cells with frame Gen 5.2 have been evaluated to a wind design load of 3600 Pa and snow design load of 6000 Pa with direct Quarter-mount method using mounting holes on the PV module, with a safety factor of 1.5 minimum.; MAX6 72/66 cells with frame Gen 5.6 have been evaluated to a wind design load of 3000 Pa and snow design load of 6000 Pa with direct Quarter-mount method using mounting holes on the PV module, with a safety factor of 1.5 minimum.; Modules are to be mounted to the Rail using the clamps located on the longer side, 50mm to 400mm from short edge of the module in portrait orientation; [2]
Grounding
- Grounding
- Attach a lay-in lug (Ilsco GBL-4DBT) to one of the grounding holes on the module frame, and attach the ground conductor to the lug.; Use an external-tooth star washer between the lug and the module frame in order to pierce the anodizing and establish electrical contact with the aluminum frame.; The assembly must end with a nut that’s torqued to 1.67–2.08 ft-lbs (for a #10-32 bolt). [2]