Charged Reviews · Quick reference
Maxeon Solar Technologies SPR-E-Flex-100
- Brand
- Maxeon Solar Technologies
- Model
- SPR-E-Flex-100
- SKU / part number
- SPR-E-Flex-100[1]
- Category
- Solar panels

Electrical at STC
| Rated output (STC) | 100 W[1, 4] |
|---|---|
| Module efficiency | ? |
| Voltage at max power (Vmp) | 17.1 V[1, 4] |
| Current at max power (Imp) | 5.9 A[1, 4] |
| Open-circuit voltage (Voc) | 21.4 V[1, 4] |
| Short-circuit current (Isc) | 6.3 A[1, 4] |
| Power tolerance | ? |
Temperature and system limits
| Temperature coefficient, Pmax | -0.35 %/°C[1, 4] |
|---|---|
| Temperature coefficient, Voc | ? |
| Temperature coefficient, Isc | ? |
| Maximum system voltage | ? |
| Maximum series fuse | 15 A[4] |
| NOCT / NMOT | ? |
| Rated output at NMOT | ? |
| Operating temperature | -40 to 85 °C[4] |
Cells and construction
| Cell technology | Prime monocrystalline 25% and 23% efficiency SunPower IBC cells[1] |
|---|---|
| Cell count | ? |
| Bifacial | ? |
| Bifaciality | ? |
| Frame | ? |
| Front glass | ? |
| Back cover | ? |
| Panel format | flexible[1] |
Mechanical and connections
| Dimensions | 3.2 D × 555 W × 1,150 L mm[1] |
|---|---|
| Weight | 2.2 kg / 4.85 lb[1] |
| Connectors | MC4 compatible[1] |
| Cable length | ? |
| Junction box rating | IP67[4] |
| Mounting | ? |
| Design load, front | ? |
| Design load, rear | ? |
Installation (from the manual)
Conductors
| Cable bending radius / connector notes | SunPower recommends a conservative minimum cable bend radius equal to or greater than 40 mm (1.5”).[4] |
|---|
Clearances and orientation
| Mounting methods and clamp zones | Modules may be mounted using the grommet holes as attachment points or using an adhesive on the panel backside. SunPower makes no claim to preferred attachment method nor to the safety of the attachment.; Modules may be mounted at any angle, from horizontal to vertical. To reduce soiling, modules should be mounted at a minimum of 10 degrees.; To prevent water from entering the junction box, which could present a safety hazard, modules should be oriented with the junction box in the uppermost position.[4] |
|---|
Not in the manual: Torque, Grounding
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.