Charged Reviews · Quick reference
LG Electronics LG380M1C-A6 380W NeON 2 ACe Solar Panel
- Brand
- LG Electronics
- Model
- LG380M1C-A6
- SKU / part number
- ?
- Category
- Solar panels
chargedreviews.com/panels/lg-electronics-lg380m1c-a6
Electrical at STC
Temperature and system limits
- Temperature coefficient, Pmax
- ?
- Temperature coefficient, Voc
- ?
- Temperature coefficient, Isc
- ?
- Maximum system voltage
- ?
- Maximum series fuse
- ?
- NOCT / NMOT
- ?
- Rated output at NMOT
- ?
Cells and construction
Mechanical and connections
Installation (from the manual)
Torque
- Clamp or bolt torque
- 4 to 5 N·m [1]
Conductors
- Cable bending radius / connector notes
- A minimum bending radius R≥ 55mm (5 x Cable diameter) must be maintained. [1]
Clearances and orientation
- Mounting methods and clamp zones
- Fig. 1 Bolting Type: ① : 7.9 in(200mm), ② : 11.8 in(300mm); Front : 5400Pa(113psf) Rear : 4000Pa(84psf); Fig. 2 Clamping Type: A : 7.9 in(200mm), B : 15.7 in(400mm), Front : 5400Pa(113psf) Rear : 4000Pa(84psf); A : 0.0 in(0mm), B : 25.6 in(650mm), Front : 2400Pa(50psf) Rear : 2400Pa(50psf); Fig. 3 Clamping Type: A : 7.9 in(200mm), B : 15.7 in(400mm); Front : 4000Pa(84psf) Rear : 4000Pa(84psf); Fig. 4 Clamping Type: A : 4.7 in(120mm), Front : 1800Pa(38psf) Rear : 1800Pa(38psf); B : 7.9 in(200mm), Front : 2400Pa(50psf) Rear : 2400Pa(50psf); Fig. 5 Clamping Type: A : 7.9 in(200mm), B : 15.7 in(400mm), Front : 5400Pa(113psf) Rear : 4000Pa(84psf); C : 4.7 in(120mm), Front : 5400Pa(113psf) Rear : 1800Pa(38psf); Fig. 6 Clamping Type: *4point(①) A : 4.7 in (120mm), Front : 1800Pa(38psf) Rear : 1800Pa(38psf); 6point (①+②) A : 120mm, B : 33.2±3.9 in (843±100mm), Front : 5400Pa(113psf) Rear : 4000Pa(84psf) [1]
Grounding
- Grounding
- To electrically connect, it recommends that you use one M4 stainless steel bolt, one nut, one spring washer, two flat washers, one cup washer and, one star washer. (Minimum torque : 4~5 N•m); Each grounding point on each PV frame is identified with ground symbol.; LG AC Modules need to be grounded by using an external grounding equipment conductor. [1]