Charged ReviewsSaved 0Compare 0Login

Charged Reviews · Quick reference

Jinko Solar JKM570N-72HL4-TV

Brand
Jinko Solar
Model
JKM570N-72HL4-TV
SKU / part number
JKM570N-72HL4-TV Provisional [1]
Category
Solar panels

chargedreviews.com/panels/jinko-solar-jkm570n-72hl4-tv

Electrical at STC

Rated output (STC)
570 W [2] [1]
Module efficiency
22.07 % Provisional [1]
Voltage at max power (Vmp)
43.9 V [2] [1]
Current at max power (Imp)
12.99 A [2] [1]
Open-circuit voltage (Voc)
52.29 V [2] [1]
Short-circuit current (Isc)
13.66 A [2] [1]
Power tolerance
?

Temperature and system limits

Temperature coefficient, Pmax
-0.29 %/°C [2] [1]
Temperature coefficient, Voc
-0.25 %/°C [2]
Temperature coefficient, Isc
0.045 %/°C [2]
Maximum system voltage
1,500 V [2] [1]
Maximum series fuse
30 A [2]
NOCT / NMOT
?
Rated output at NMOT
?
Operating temperature
?

Cells and construction

Cell technology
N-Type TOPCon Provisional [1]
Cell count
?
Bifacial
yes Provisional [1]
Bifaciality
?
Frame
?
Front glass
?
Back cover
?
Panel format
?

Mechanical and connections

Dimensions
W 1,134 × L 2,278 × D 35 mm / W 44.65 × L 89.69 × D 1.4 in converted Provisional [1]
Weight
27 kg / 60 lb converted [1]
Connectors
?
Cable length
?
Junction box rating
?
Mounting
?
Design load, front
?
Design load, rear
?

Installation (from the manual)

Conductors

Cable bending radius / connector notes
The bending radius of cables shall be no less than 4 x the cable OD (outer diameter) [2]

Clearances and orientation

Mounting methods and clamp zones
Mounting with Clamps at Long Sides of the Frames (Table 4): JKMxxxN-72HL4-(V)-(TV) 2278*1134*35, J A/5-50, K A/5+50, Test Load +5400 / -2400 Pa; Mounting with Tracker (Table 7): Eagle® 72HM G6T (JKMxxxN-72HL4-TV) NEXTracker 1P 400mm hole distance 2250/-2100; NEXTracker 1P 790mm hole distance 2700/-2400 [2]

Grounding

Grounding
Jinko modules can be grounded using bolts.; Attach the equipment grounding conductor to the module frame using the hole and hardware provided.; ground 6-12AWG wire; It is recommended that the applied torque is 1.7~2.0 ft-lbs (2.3~2.8 N*m). [2]

Not in the manual: Torque

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

Jinko Solar JKM570N-72HL4-TV · JKM570N-72HL4-TV

Warranty

Product warranty?
Power warranty term?
First-year degradation?
Annual degradation after year one?
Warranted final output?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?

Certifications and listings

UL 61730?
UL 1703?
IEC 61215?
IEC 61730?
IEC 62804?
CEC listing?
CECVerified listed as of snapshot [3]

Documents and sources

  1. Jinko Solar 570W 144 Half-Cell N-Type 1500V Silver Bifacial Solar Panel, JKM570N-72HL4-TV Product page · Checked Sep 16, 2026 https://www.greentechrenewables.com/product/jinko-solar-570w-144-half-cell-n-type-1500v-silver-bifacial-solar-panel-jkm570n-72hl4-tv
  2. JinkoSolar User Manual (UL61730), JinkoSolar Photovoltaic Module (U.S. UL 61730 edition, Edition 06/2024) Installation manual · Revision Edition 06/2024 · Revised 2024-06 · Checked Oct 1, 2026 https://jinkosolar.us/wp-content/uploads/2024/06/202406-UL-61730-Installation-Manual-G5-G6.pdf
  3. CEC PV Module List, official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) Government equipment list (spreadsheet) · Revision Data unchanged since October 1, 2026 · Revised Oct 1, 2026 · Checked Oct 10, 2026 https://solarequipment.energy.ca.gov/Home/DownloadtoExcel?filename=PVModuleList

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/panels/jinko-solar-jkm570n-72hl4-tvSome links pay us a commission. That does not affect what we record.