| Field | Value | Conditions | Source |
|---|---|---|---|
| Current at max power | 12.84 A | Printed as "Maximum Power Current (Imp, A) 12.39 12.48 12.57 12.66 12.75 12.84 12.93 13.02 13.11 13.20 13.27 13.34" in Appendix 2 (Electrical Specifications) of JinkoSolar's User Manual (UL61730), Edition 06/2024, the Group 1 table (header "Module Type Group 1 xxx = 495 500 505 510 515 520 525 530 535 540 545 550"); the value 12.84 is in the xxx = 520 column, column 6 of 12 columns, which is JKM520M-72HL4-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source. Where: PDF page 24, Appendix 2 (Electrical Specifications), Group 1 table, "Maximum Power Current (Imp, A)" row, xxx = 520 column | [2] [1] |
| Short-circuit current | 13.54 A | Printed as "Short-circuit Current (Isc, A) 13.18 13.25 13.32 13.40 13.47 13.54 13.64 13.71 13.79 13.87 13.94 14.01" in Appendix 2 (Electrical Specifications) of JinkoSolar's User Manual (UL61730), Edition 06/2024, the Group 1 table (header "Module Type Group 1 xxx = 495 500 505 510 515 520 525 530 535 540 545 550"); the value 13.54 is in the xxx = 520 column, column 6 of 12 columns, which is JKM520M-72HL4-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source. Where: PDF page 24, Appendix 2 (Electrical Specifications), Group 1 table, "Short-circuit Current (Isc, A)" row, xxx = 520 column | [2] [1] |
| Voltage at max power | 40.5 V | Printed as "Maximum Power Voltage (Vmp, V) 39.96 40.07 40.18 40.29 40.40 40.50 40.61 40.71 40.81 40.91 41.07 41.23" in Appendix 2 (Electrical Specifications) of JinkoSolar's User Manual (UL61730), Edition 06/2024, the Group 1 table (header "Module Type Group 1 xxx = 495 500 505 510 515 520 525 530 535 540 545 550"); the value 40.50 is in the xxx = 520 column, column 6 of 12 columns, which is JKM520M-72HL4-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source. Where: PDF page 24, Appendix 2 (Electrical Specifications), Group 1 table, "Maximum Power Voltage (Vmp, V)" row, xxx = 520 column | [2] [1] |
| Open-circuit voltage | 49.2 V | Printed as "Open-circuit Voltage (Voc, V) 48.82 48.90 48.98 49.05 49.12 49.20 49.27 49.35 49.42 49.49 49.65 49.81" in Appendix 2 (Electrical Specifications) of JinkoSolar's User Manual (UL61730), Edition 06/2024, the Group 1 table (header "Module Type Group 1 xxx = 495 500 505 510 515 520 525 530 535 540 545 550"); the value 49.20 is in the xxx = 520 column, column 6 of 12 columns, which is JKM520M-72HL4-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source. Where: PDF page 24, Appendix 2 (Electrical Specifications), Group 1 table, "Open-circuit Voltage (Voc, V)" row, xxx = 520 column | [2] [1] |
| Bifacial | yes Provisional | Seller-listed specification; not independently verified. Where: Product category | [1] |
| Cell type | Monocrystalline Provisional | Seller-listed specification; not independently verified. Where: technology | [1] |
| Grounding | Jinko modules can be grounded using bolts.; Attach the equipment grounding conductor to the module frame using the hole and hardware provided.; ground 6-12AWG wire; It is recommended that the applied torque is 1.7~2.0 ft-lbs (2.3~2.8 N*m). | Printed as "Jinko modules can be grounded using bolts. Attach the equipment grounding conductor to the module frame using the hole and hardware provided." in section 3 (Wiring and Connection) of JinkoSolar's User Manual (UL61730), Edition 06/2024, followed by "a stainless- steel bolt is used between the ground 6-12AWG wire and module frame" and the recommended torque quoted here. Table 8 lists the grounding hardware: stainless steel M4 bolt, spring washer, nut, star washer and plain washers. Third-party grounding devices only if UL2703 certified with Jinko modules. Where: PDF page 17, section 3 Wiring and Connection, item 5 and the grounding hardware table | [2] |
| Weight | 29.4 kg / 64.8 lb converted | Printed as "Weight 64.82 Lbs." in the Jinko Solar 520W 144 Half-Cell 1500V Silver Bifacial Solar Panel, JKM520M-72HL4-TV; the maker prints pounds only, converted to kilograms. Revised on 30 September 2026: The maker prints this weight in pounds only; the stored kilograms were an unlabeled conversion, now labeled with the printed pounds kept (Project Manager, September 30, 2026). Where: Seller product page (Greentech Renewables), Technical Specifications, Weight SourcesConverted: 64.82 lb x 0.45359237 kg/lb, rounded to 0.01 kg | [1] |
| Dimensions | W 1,134 × L 2,278 × D 35 mm / W 44.65 × L 89.69 × D 1.4 in converted Provisional | Seller-listed specification; not independently verified. Where: Dimensions | [1] |
| Rated power | 520 W | Printed as "Maximum Power at STC (Pmax, Wp) 495 500 505 510 515 520 525 530 535 540 545 550" in Appendix 2 (Electrical Specifications) of JinkoSolar's User Manual (UL61730), Edition 06/2024, the Group 1 table (header "Module Type Group 1 xxx = 495 500 505 510 515 520 525 530 535 540 545 550"); the value 520 is in the xxx = 520 column, column 6 of 12 columns, which is JKM520M-72HL4-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source. Where: PDF page 24, Appendix 2 (Electrical Specifications), Group 1 table, "Maximum Power at STC (Pmax, Wp)" row, xxx = 520 column | [2] [1] |
| Series fuse | 30 A Provisional | Seller-listed specification; not independently verified. Where: series-fuse-rating | [1] |
| Mounting methods | Mounting with Clamps at Long Sides of the Frames (Table 4): JKMxxxM-72HL4-(V)-(TV) 2278*1134*35, J A/5-50, K A/5+50, Test Load +5400 / -2400 Pa; Mounting with Tracker (Table 7): Eagle® 72HM G5B (JKMxxxM-72HL4-TV) NEXTracker 1P 400mm hole distance 2175/-2100; NEXTracker 1P 790mm hole distance 2700/-2400 | Printed as "JKMxxxM-72HL4-(V)-(TV) 2278*1134*35 A/5-50 A/5+50 +5400 / -2400" in JinkoSolar's User Manual (UL61730), Edition 06/2024, with the other rows quoted here from the same mounting tables (the value lists each method with its table heading and the row for this series as printed). Tables 5 and 6 (clamps on the short sides and on long and short sides) do not list this series. The tracker figures are, in Jinko's words, "based on Jinko’s internal results" and not evaluated by UL. J and K are the clamp zone limits; A is the length of the long side. Where: PDF page 14 (Table 4) and PDF page 16 (Table 7) | [2] |
| Cable bend radius | The bending radius of cables shall be no less than 4 x the cable OD (outer diameter) | Printed as "The bending radius of cables shall be no less than 4 x the cable OD (outer diameter)" in the wire management instructions of JinkoSolar's User Manual (UL61730), Edition 06/2024, a series-wide instruction for the modules the manual covers. Where: PDF page 19, section 3 Wiring and Connection, item 14 (wire management) | [2] |
| Max series fuse | 30 A | Printed as "Maximum series overcurrent protective device rating 30A" for the whole Group 1 table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 06/2024, one figure for every power class in it, including JKM520M-72HL4-TV. Where: PDF page 24, Appendix 2, Group 1 table, "Maximum series overcurrent protective device rating" row | [2] |
| Max system voltage | 1,500 V | Printed as "Maximum system Voltage 1500VDC" for the whole Group 1 table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 06/2024, one figure for every power class in it, including JKM520M-72HL4-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source. Where: PDF page 24, Appendix 2, Group 1 table, "Maximum system Voltage" row | [2] [1] |
| Module efficiency | 20.17 % Provisional | Seller-listed specification; not independently verified. Where: efficiency | [1] |
| Temperature coefficient | -0.35 %/°C | Printed as "Temperature coefficients 0.048% for Isc -0.29% for Voc -0.35% for Pmax" for the whole Group 1 table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 06/2024; the Pmax figure is -0.35%, a temperature coefficient (per °C) for every power class in the table, including JKM520M-72HL4-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source. Where: PDF page 24, Appendix 2, Group 1 table, "Temperature coefficients" row (Pmax) | [2] [1] |
| Isc temperature coefficient | 0.048 %/°C | Printed as "Temperature coefficients 0.048% for Isc -0.29% for Voc -0.35% for Pmax" for the whole Group 1 table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 06/2024; the Isc figure is 0.048%, a temperature coefficient (per °C) for every power class in the table, including JKM520M-72HL4-TV. Where: PDF page 24, Appendix 2, Group 1 table, "Temperature coefficients" row (Isc) | [2] |
| Voc temperature coefficient | -0.29 %/°C | Printed as "Temperature coefficients 0.048% for Isc -0.29% for Voc -0.35% for Pmax" for the whole Group 1 table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 06/2024; the Voc figure is -0.29%, a temperature coefficient (per °C) for every power class in the table, including JKM520M-72HL4-TV. Where: PDF page 24, Appendix 2, Group 1 table, "Temperature coefficients" row (Voc) | [2] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Module efficiency needed; Product warranty needed; Power warranty needed; First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
0.35 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed as "Temperature coefficients 0.048% for Isc -0.29% for Voc -0.35% for Pmax" for the whole Group 1 table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 06/2024; the Pmax figure is -0.35%, a temperature coefficient (per °C) for every power class in the table, including JKM520M-72HL4-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
0.05654 against 0.01227 kg per W, the lowest documented for a solar panel (calculated from maker figures): Go Power! 110-Watt Solar Flex™ Module
29.4 kg / 520 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.
Not documented, 0 points: Product warranty, Power warranty, First-year degradation.
Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4
How it worksUnknown: no warranty facts recorded.
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Archived copy captured on 2026-10-01.
Location: Cover page (edition) and Appendix 1, Applicable Products (scope)
Retrieved Oct 1, 2026
JinkoSolar's own installation manual for its U.S. (UL 61730) photovoltaic modules, captured 1 October 2026 from jinkosolar.us, printed as Edition 06/2024 on the cover; its Appendix 1 (Applicable Products) names JKMxxxM-72HL4-TV (Group 1, xxx = 495~550), JKMxxxN-54HL4-B (Group 2), JKMxxxN-72HL4-TV (Group 3, xxx = 555~585), JKMxxxN-72HL4-BDV (Group 4) and JKMxxxN-72HL4-BDX (Group 5). Jinko US still lists it on its Installation Manuals download page ("202406 – UL 61730 Installation Manual (G5, G6)"); it is the newest edition there that names the JKMxxxM-72HL4-TV and JKMxxxN-72HL4-TV series. It gives series-level installation instructions (mounting zones, test loads, torques, grounding, wiring) and, in Appendix 2, the STC electrical table per power class of each listed series; it does not establish other model ratings. Manufacturer instructions, not independent tests.
Archived copy of a document published by JinkoSolar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what JinkoSolar published. Original address: https://jinkosolar.us/wp-content/uploads/2024/06/202406-UL-61730-Installation-Manual-G5-G6.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 780807cf1440ce1ea21afcd169721f8215ca2520118038a474b8340d4544218c
Linked from the GreenTech Renewables product page with link text "View".
Location: ZZ299200060_DS.pdf
Retrieved Sep 18, 2026
Original PDF preserved byte for byte, found linked from the GreenTech Renewables listing https://www.greentechrenewables.com/product/jinko-solar-525w-144-half-cell-1500v-silver-bifacial-solar-panel-jkm525m-72hl4-tv. The revision is whatever was published at this URL on the access date; exact variant coverage inside the document was not separately verified and no later revision was checked.
SHA-256: 71e5ee2996e5d2a1577d3841c46a4f15cf3639c4671885bb910086e4ebff307e
Archived copy of a document published by cdn.myced.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what cdn.myced.com published. Original address: https://cdn.myced.com/images/Products/ZZ0000/ZZ2992/00000/ZZ299200060_DS.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 71e5ee2996e5d2a1577d3841c46a4f15cf3639c4671885bb910086e4ebff307e
Location: Product listing
Retrieved Sep 16, 2026
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by cdn.myced.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what cdn.myced.com published. Original address: https://cdn.myced.com/images/Products/ZZ0000/ZZ2992/00000/ZZ299200060_DS.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 71e5ee2996e5d2a1577d3841c46a4f15cf3639c4671885bb910086e4ebff307e
Archived copy of a document published by JinkoSolar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what JinkoSolar published. Original address: https://jinkosolar.us/wp-content/uploads/2024/06/202406-UL-61730-Installation-Manual-G5-G6.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 780807cf1440ce1ea21afcd169721f8215ca2520118038a474b8340d4544218c
No sourced accessories or replacement parts listed yet.
Manufacturer SKU JKM520M-72HL4-TV
Observed Oct 11, 2026
Product / system scope unresolved. Model JKM520M-72HL4-TV listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Jinko Solar Co., Ltd, as "JKM520M-72HL4-TV", CEC listing date 2021-04-01. This is an equipment listing, not UL certification or complete-system approval.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: panels-0.4-personal documented pct: 21 basis: Unknown missing: Module efficiency needed Product warranty needed Power warranty needed First-year degradation needed criteria: key: efficiency label: Module efficiency value: Unknown unit: Unknown shown: 20.17 % · not confirmed shown detail: Unknown state: unconfirmed points: 0 ceiling: 26 weight: 26 share: Unknown covered: no missing: yes folded: no reason: not-counted reason text: A value is on file but is not counted: it carries a warning or is not confirmed. note: Not documented. display note: Unknown Sources: [1] key: warranty label: Product warranty value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 21 weight: 21 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: performanceWarranty label: Power warranty value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: powerTemperature label: Power temperature coefficient value: 0.35 unit: Unknown shown: -0.35 %/°C shown detail: Unknown state: documented points: 10.1 ceiling: 16 weight: 16 share: 62.9 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown key: degradation label: First-year degradation value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: weightPerWatt label: Weight / watt value: 0.0565 unit: Unknown shown: 29.4 kg / 520 W shown detail: Unknown state: documented points: 1.1 ceiling: 5 weight: 5 share: 21.7 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: 29.4 kg / 520 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel. display note: Unknown | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.