Read from the publisher's own document for this exact model (Page 2, Mechanical Characteristics, "Frame"). The publisher prints no further test condition for this row; no value was taken from another model.
Printed as "Maximum Power Current (Imp, A) 9.82 9.92 10.02 10.12 10.22 10.32 10.42 10.52 10.62 10.72 10.82 10.92" in Appendix 2 (Electrical Specifications) of JinkoSolar's User Manual (UL61730), Edition 08/2023, the Group 7 table (header "Module Type Group 7 xxx = 420 425 430 435 440 445 450 455 460 465 470 475"); the value 10.52 is in the xxx = 455 column, column 8 of 12 columns, which is JKM455M-7RL3-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Where: PDF page 27, Appendix 2 (Electrical Specifications), Group 7 table, "Maximum Power Current (Imp, A)" row, xxx = 455 column
Printed as "Short-circuit Current (Isc, A) 10.63 10.72 10.81 10.90 10.99 11.08 11.17 11.26 11.35 11.44 11.53 11.63" in Appendix 2 (Electrical Specifications) of JinkoSolar's User Manual (UL61730), Edition 08/2023, the Group 7 table (header "Module Type Group 7 xxx = 420 425 430 435 440 445 450 455 460 465 470 475"); the value 11.26 is in the xxx = 455 column, column 8 of 12 columns, which is JKM455M-7RL3-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Where: PDF page 27, Appendix 2 (Electrical Specifications), Group 7 table, "Short-circuit Current (Isc, A)" row, xxx = 455 column
Printed as "Maximum Power Voltage(Vmp, V) 42.77 42.85 42.92 42.99 43.06 43.13 43.19 43.25 43.32 43.38 43.44 43.50" in Appendix 2 (Electrical Specifications) of JinkoSolar's User Manual (UL61730), Edition 08/2023, the Group 7 table (header "Module Type Group 7 xxx = 420 425 430 435 440 445 450 455 460 465 470 475"); the value 43.25 is in the xxx = 455 column, column 8 of 12 columns, which is JKM455M-7RL3-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Where: PDF page 27, Appendix 2 (Electrical Specifications), Group 7 table, "Maximum Power Voltage(Vmp, V)" row, xxx = 455 column
Printed as "Open-circuit Voltage (Voc, V) 51.10 51.20 51.30 51.40 51.50 51.60 51.70 51.80 51.90 52.00 52.10 52.16" in Appendix 2 (Electrical Specifications) of JinkoSolar's User Manual (UL61730), Edition 08/2023, the Group 7 table (header "Module Type Group 7 xxx = 420 425 430 435 440 445 450 455 460 465 470 475"); the value 51.80 is in the xxx = 455 column, column 8 of 12 columns, which is JKM455M-7RL3-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Where: PDF page 27, Appendix 2 (Electrical Specifications), Group 7 table, "Open-circuit Voltage (Voc, V)" row, xxx = 455 column
Read from the JinkoSolar EAGLE 78TR G4b 455-475 W US datasheet (JKM455-475M-7RL3-TV-A3-US), column "JKM455M-7RL3-TV" of the table headed "Module Type JKM455M-7RL3-TV JKM460M-7RL3-TV JKM465M-7RL3-TV JKM470M-7RL3-TV JKM475M-7RL3-TV". The datasheet title prints "455-475 WATT TILING RIBBON BIFACIAL MODULE". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: JinkoSolar EAGLE 78TR G4b 455-475 W US datasheet (JKM455-475M-7RL3-TV-A3-US), page 1, title
Jinko modules can be grounded using bolts.; Attach the equipment grounding conductor to the module frame using the hole and hardware provided.; ground 6-12AWG wire; It is recommended that the applied torque is 1.7~2.0 ft-lbs (2.3 to 2.8 N*m).
Printed as "Jinko modules can be grounded using bolts. Attach the equipment grounding conductor to the module frame using the hole and hardware provided." in section 3 (Wiring and Connection) of JinkoSolar's User Manual (UL61730), Edition 08/2023, followed by "a stainless- steel bolt is used between the ground 6-12AWG wire and module frame" and the recommended torque quoted here. Table 7 lists the grounding hardware: stainless steel M4 bolt, spring washer, nut, star washer and plain washers. Third-party grounding devices only if UL2703 certified with Jinko modules.
Where: PDF page 17, section 3 Wiring and Connection, item 5 and the grounding hardware table
Printed as "Weight 26.5kg (58.42lbs)" in JinkoSolar EAGLE 78TR G4b 455-475 W (JKM455-475M-7RL3-TV) datasheet, JinkoSolar EAGLE 78TR G4b 455-475 W US datasheet (JKM455-475M-7RL3-TV-A3-US), page 2, Mechanical Characteristics, "Weight" row, single value printed for every model in the table. Revised on 1 October 2026: The datasheet prints this value on page 2 for this model, not on page 1 as the old reference said.
Where: JinkoSolar EAGLE 78TR G4b 455-475 W US datasheet (JKM455-475M-7RL3-TV-A3-US), page 2, Mechanical Characteristics, "Weight" row, single value printed for every model in the table
3.2mm, Anti-Reflection Coating High Transmission, Low Iron, Tempered Glass
Printed as "Front Glass 3.2mm, Anti-Reflection Coating High Transmission, Low Iron, Tempered Glass" in JinkoSolar's EAGLE 78TR G4b 455-475 W (JKM455-475M-7RL3-TV) datasheet, captured on September 28, 2026.
Where: Page 2, Mechanical Characteristics, Front Glass row
Printed as "The torque value for M8 bolt is 16~20 N*m and M6 bolt is 8 N*m." in section 2.3.1 (Mounting with Bolts) of JinkoSolar's User Manual (UL61730), Edition 08/2023; this is the M8 bolt torque for bolt mounting through the 14x9 inner holes. For clamps, section 2.3.2 says to consult the clamp or racking supplier for the torque value.
Where: PDF page 10, section 2.3.1 Mounting with Bolts, first paragraph
Read from the publisher's own document for this exact model (Page 2, Mechanical Characteristics, "Junction Box"). The publisher prints no further test condition for this row; no value was taken from another model.
W 1,032 × L 2,205 × D 40 mm / W 40.63 × L 86.81 × D 1.6 in converted
Printed as "Dimensions 2205*1032*40mm (86.81*40.63*1.57 inch)" for the whole Group 7 table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 08/2023, one size for every power class in it, including JKM455M-7RL3-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Where: PDF page 27, Appendix 2, Group 7 table, "Dimensions" row
Printed as "Maximum Power at STC (Pmax, Wp) 420 425 430 435 440 445 450 455 460 465 470 475" in Appendix 2 (Electrical Specifications) of JinkoSolar's User Manual (UL61730), Edition 08/2023, the Group 7 table (header "Module Type Group 7 xxx = 420 425 430 435 440 445 450 455 460 465 470 475"); the value 455 is in the xxx = 455 column, column 8 of 12 columns, which is JKM455M-7RL3-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Where: PDF page 27, Appendix 2 (Electrical Specifications), Group 7 table, "Maximum Power at STC (Pmax, Wp)" row, xxx = 455 column
Printed as "Maximum Series Fuse Rating 25A" in JinkoSolar EAGLE 78TR G4b 455-475 W (JKM455-475M-7RL3-TV) datasheet, JinkoSolar EAGLE 78TR G4b 455-475 W US datasheet (JKM455-475M-7RL3-TV-A3-US), page 2, Maximum Ratings, "Maximum Series Fuse Rating" row, single value printed for every model in the table. Revised on 1 October 2026: The datasheet prints this value on page 2 for this model, not on page 1 as the old reference said.
Where: JinkoSolar EAGLE 78TR G4b 455-475 W US datasheet (JKM455-475M-7RL3-TV-A3-US), page 2, Maximum Ratings, "Maximum Series Fuse Rating" row, single value printed for every model in the table
Mounting with Bolts (four 14x9 inner mounting holes, M8): Test load: 5400Pa (positive) & 2400Pa (negative), Design load: 3600Pa (positive) & 1600Pa(negative); Mounting with Clamps at Long Sides of the Frames (Max. Test Pressure: 5400Pa (positive) & 2400Pa (negative)): JKMxxxM-7RL3-TV 2205*1032*40, J 430, K 570; 2205*1032*35, J A/4-50, K A/4+50; Clamping Mounting on Long/Short Sides (Max. Test Pressure: 2400Pa (positive) & 2400Pa (negative)): JKMxxxM-7RL3-TV 2205*1032*40, J 130, K 240, M A/4-50, N A/4+50
Printed as "JKMxxxM-7RL3-TV 2205*1032*40 430 570 2205*1032*35 A/4-50 A/4+50" in JinkoSolar's User Manual (UL61730), Edition 08/2023, with the other rows quoted here from the same mounting tables (the value lists each method with its table heading and the row for this series as printed). Table 5 (clamps on the short sides, PDF page 15) does not list JKMxxxM-7RL3-TV, so short-side clamping is not given for it. J and K are the clamp zone limits measured from the module end; A is the length of the long side.
Where: PDF page 10 (2.3.1 Mounting with Bolts, Table 2), PDF page 14 (Table 4) and PDF page 16 (Table 6)
The bending radius of cables shall be no less than 4 x the cable OD (outer diameter)
Printed as "The bending radius of cables shall be no less than 4 x the cable OD (outer diameter)" in the wire management instructions of JinkoSolar's User Manual (UL61730), Edition 08/2023, a series-wide instruction for the modules the manual covers.
Where: PDF page 19, section 3 Wiring and Connection, item 14 (wire management)
Printed as "Maximum series overcurrent protective device rating 25A" for the whole Group 7 table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 08/2023, one figure for every power class in it, including JKM455M-7RL3-TV.
Where: PDF page 27, Appendix 2, Group 7 table, "Maximum series overcurrent protective device rating" row
Printed as "Maximum system Voltage 1500VDC" for the whole Group 7 table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 08/2023, one figure for every power class in it, including JKM455M-7RL3-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Where: PDF page 27, Appendix 2, Group 7 table, "Maximum system Voltage" row
Printed as "Module Efficiency STC (%) 20.00% 20.21% 20.43% 20.65% 20.87%" in JinkoSolar EAGLE 78TR G4b 455-475 W (JKM455-475M-7RL3-TV) datasheet, JinkoSolar EAGLE 78TR G4b 455-475 W US datasheet (JKM455-475M-7RL3-TV-A3-US), page 2, Electrical Characteristics, "Module Efficiency STC (%)" row, JKM455M-7RL3-TV column. Revised on 1 October 2026: The datasheet prints this value on page 2 for this model, not on page 1 as the old reference said.
Printed as "Temperature coefficients 0.048% for Isc -0.28% for Voc -0.35% for Pmax" for the whole Group 7 table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 08/2023; the Pmax figure is -0.35%, a temperature coefficient (per °C) for every power class in the table, including JKM455M-7RL3-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Where: PDF page 27, Appendix 2, Group 7 table, "Temperature coefficients" row (Pmax)
Printed as "Temperature coefficients 0.048% for Isc -0.28% for Voc -0.35% for Pmax" for the whole Group 7 table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 08/2023; the Isc figure is 0.048%, a temperature coefficient (per °C) for every power class in the table, including JKM455M-7RL3-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Where: PDF page 27, Appendix 2, Group 7 table, "Temperature coefficients" row (Isc)
Printed as "Temperature coefficients 0.048% for Isc -0.28% for Voc -0.35% for Pmax" for the whole Group 7 table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 08/2023; the Voc figure is -0.28%, a temperature coefficient (per °C) for every power class in the table, including JKM455M-7RL3-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Where: PDF page 27, Appendix 2, Group 7 table, "Temperature coefficients" row (Voc)
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Printed as "Module Efficiency STC (%) 20.00% 20.21% 20.43% 20.65% 20.87%" in JinkoSolar EAGLE 78TR G4b 455-475 W (JKM455-475M-7RL3-TV) datasheet, JinkoSolar EAGLE 78TR G4b 455-475 W US datasheet (JKM455-475M-7RL3-TV-A3-US), page 2, Electrical Characteristics, "Module Efficiency STC (%)" row, JKM455M-7RL3-TV column. Revised on 1 October 2026: The datasheet prints this value on page 2 for this model, not on page 1 as the old reference said.
Power temperature coefficient-0.35 %/°C10.1 / 16.0
0.35 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed as "Temperature coefficients 0.048% for Isc -0.28% for Voc -0.35% for Pmax" for the whole Group 7 table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 08/2023; the Pmax figure is -0.35%, a temperature coefficient (per °C) for every power class in the table, including JKM455M-7RL3-TV. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
CECauthority listing reportedlisted as of snapshot[4]
Scope
equipment listing
Covered models
JKM455M-7RL3-TV
Limitations
Model JKM455M-7RL3-TV listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Jinko Solar Co., Ltd, as "JKM455M-7RL3-TV", CEC listing date 2020-09-11. This is an equipment listing, not UL certification or complete-system approval.
Location: Cover page (edition) and Appendix 1, Applicable Products (scope)
Retrieved Oct 1, 2026
JinkoSolar's own installation manual for its U.S. (UL 61730) photovoltaic modules, captured 1 October 2026 from jinkosolar.us, printed as Edition 08/2023 on the cover; its Appendix 1 (Applicable Products) lists 18 groups, among them JKMxxxM-72HL, JKMxxxM-72HL-V and JKMxxxM-72HBL (Group 2, xxx = 395~420) with JKMxxxM-72HBL-V (xxx = 370~420), JKMxxxM-7RL3-TV (Group 7, xxx = 420~475) and JKMxxxM-6RL3-B (Group 8, xxx = 365~400). Jinko US still lists it on its Installation Manuals download page ("20230801 – UL 61730 Installation Manual"); it is the newest edition there that names the JKMxxxM-7RL3-TV, JKMxxxM-6RL3-B, JKMxxxM-72HL-V and JKMxxxM-72HBL-V series. It gives series-level installation instructions (mounting zones, test loads, torques, grounding, wiring) and, in Appendix 2, the STC electrical table per power class of each listed series; it does not establish other model ratings. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by JinkoSolar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
US datasheet with one column per module type from JKM455M-7RL3-TV to JKM475M-7RL3-TV; shared mechanical, temperature and rating rows apply to the whole five-model table.
Archived copies
Archived copy of a document published by JinkoSolar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
PDF
ViewOfficial · cdn.myced.com · Official datasheet · PDFSource details
Revision
Not stated
Revision date
Not stated
Linked from the GreenTech Renewables product page with link text "View".
Location: ZZ299200067_DS.pdf
Retrieved Sep 18, 2026
Original PDF preserved byte for byte, found linked from the GreenTech Renewables listing https://www.greentechrenewables.com/product/jinko-solar-455w-156-half-cell-1500v-silver-bifacial-solar-panel-jkm455m-7rl3-tv. The revision is whatever was published at this URL on the access date; exact variant coverage inside the document was not separately verified and no later revision was checked.
Archived copy of a document published by cdn.myced.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by cdn.myced.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
JinkoSolar EAGLE 78TR G4b 455-475 W (JKM455-475M-7RL3-TV) datasheet
Archived copy of a document published by JinkoSolar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
JinkoSolar User Manual (UL61730), JinkoSolar Photovoltaic Module (U.S. UL 61730 edition, Edition 08/2023)
Archived copy of a document published by JinkoSolar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
JKM455M-7RL3-TV
Manufacturer SKU JKM455M-7RL3-TV
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model JKM455M-7RL3-TV listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Jinko Solar Co., Ltd, as "JKM455M-7RL3-TV", CEC listing date 2020-09-11. This is an equipment listing, not UL certification or complete-system approval.