Charged Reviews · Quick reference
Jinko Solar JKM420N-54HL4-B
- Brand
- Jinko Solar
- Model
- JKM420N-54HL4-B
- SKU / part number
- JKM420N-54HL4-B Provisional [1]
- Category
- Solar panels
chargedreviews.com/panels/jinko-solar-jkm420n-54hl4-b
Electrical at STC
- Module efficiency
- 21.51 % [3]
- Power tolerance
- ?
Temperature and system limits
Cells and construction
Mechanical and connections
Installation (from the manual)
Torque
- Clamp or bolt torque
- 16 to 20 N·m [2]
Conductors
- Cable bending radius / connector notes
- The bending radius of cables shall be no less than 4 x the cable OD (outer diameter) [2]
Clearances and orientation
- Mounting methods and clamp zones
- Bolts (Table 4): EAGLE G6R (JKMxxxN-54HL4-B) Four inner holes 860 +5400/-2400; Long side clamping (Table 7): EAGLE G6R (JKMxxxN-54HL4-B) 1722*1134*35 L=A/5±50 +5400 / -2400; Short side clamping (Table 8): EAGLE G6R (JKMxxxN-54HL4-B) 1722*1134*35 S=100~240 +1600/- 1600; Long side and short side clamping (Table 9): EAGLE G6R (JKMxxxN-54HL4-B) 1722*1134*35 100~240 A/4±50 +2400/- 2400 [2]
Grounding
- Grounding
- Jinko modules can be grounded using bolts.; Attach the equipment grounding conductor to the module frame using the hole and hardware.; ground 6-12AWG wire; It is recommended that the applied torque is 1.7~2.0 ft-lbs (2.3~2.8 N*m). [2]