Charged Reviews · Quick reference
Jinko Solar JKM405M-72HL-V
- Brand
- Jinko Solar
- Model
- JKM405M-72HL-V
- SKU / part number
- JKM405M-72HL-V Provisional [1]
- Category
- Solar panels
chargedreviews.com/panels/jinko-solar-jkm405m-72hl-v
Electrical at STC
- Module efficiency
- 20.13 % [3]
- Power tolerance
- ?
Temperature and system limits
Cells and construction
Mechanical and connections
Installation (from the manual)
Torque
- Clamp or bolt torque
- 16 to 20 N·m [2]
Conductors
- Cable bending radius / connector notes
- The bending radius of cables shall be no less than 4 x the cable OD (outer diameter) [2]
Clearances and orientation
- Mounting methods and clamp zones
- Mounting with Bolts (four 14x9 inner mounting holes, M8): Test load: 5400Pa (positive) & 2400Pa (negative), Design load: 3600Pa (positive) & 1600Pa(negative); Mounting with Clamps at Long Sides of the Frames (Max. Test Pressure: 5400Pa (positive) & 2400Pa (negative)): JKMxxxM-72H(B)L-(V) 2008*1002*40, J 280, K 420; 2008*1002*35, J A/4-50, K A/4+50; Clamping Mounting on Short Sides of the Frames (Max. Test Pressure: 1600Pa (positive) & 1600Pa(negative)): JKMxxxM-72H(B)L-(V) 2008*1002*40, J 100, K 240; Clamping Mounting on Long/Short Sides (Max. Test Pressure: 2400Pa (positive) & 2400Pa (negative)): JKMxxxM-72H(B)L-(V) 2008*1002*40, J 100, K 240, M 280, N 480 [2]
Grounding
- Grounding
- Jinko modules can be grounded using bolts.; Attach the equipment grounding conductor to the module frame using the hole and hardware provided.; ground 6-12AWG wire; It is recommended that the applied torque is 1.7~2.0 ft-lbs (2.3 to 2.8 N*m). [2]