Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: greentechrenewables.com's product image for the JAM72D40-595/MB USDC-J/F, used because no maker image of this model was found. Seller listing image, not a manufacturer-issued photo.No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Current at max power | 13.14 A Provisional | Seller-listed specification; not independently verified. Where: max-power-current | [1] |
| Short-circuit current | 14.1 A Provisional | Seller-listed specification; not independently verified. Where: short-circuit-current | [1] |
| Voltage at max power | 45.3 V Provisional | Seller-listed specification; not independently verified. Where: max-power-voltage | [1] |
| Open-circuit voltage | 54.1 V Provisional | Seller-listed specification; not independently verified. Where: open-circuit-voltage | [1] |
| Bifacial | yes Provisional | Seller-listed specification; not independently verified. Where: Product category | [1] |
| Cell type | N-Type Provisional | Seller-listed specification; not independently verified. Where: technology | [1] |
| Grounding | There is a grounding hole with 4.2 mm diameter on the edge side closer to the middle of the back frame of the modules.; The recommended torque value is 2.3 N.m.; 12 AWG copper wire can be used as the equipment grounding conductor in conjunction with the grounding bolt. | Printed as "There is a grounding hole with 4.2 mm diameter on the edge side closer to the middle of the back frame of the modules." in section 7.1 of JA Solar's PV Bifacial Double-glass Modules Installation Manual (Q/JASO-PMO-015 A/15), with the other quoted lines from the same section. Section 7.2 allows grounding through an unused mounting hole with a grounding clamp and toothed gasket (nut torque 2.0 N.m~2.2 N.m). Where: PDF page 20, section 7.1 Grounding by Using Grounding Bolt | [2] |
| Clamp torque | 18 to 24 N·m | Printed as "B. Recommended bolt torque range: 18-24N·m." in section 5.2.1 (Modules installed with clamp) of JA Solar's PV Bifacial Double-glass Modules Installation Manual (Q/JASO-PMO-015 A/15); the clamp bolt is M8. Section 5.2.2 (PDF page 11) gives 15-20N·m for M8 screws in mounting holes. Where: PDF page 9, section 5.2.1 Modules installed with clamp, item B | [2] |
| Dimensions | W 1,134 × L 2,278 × D 35 mm / W 44.65 × L 89.69 × D 1.4 in converted Provisional | Seller-listed specification; not independently verified. Where: Dimensions | [1] |
| Rated power | 595 W Provisional | Seller-listed specification; not independently verified. Where: watts-stc | [1] |
| Series fuse | 30 A Provisional | Seller-listed specification; not independently verified. Where: series-fuse-rating | [1] |
| Cable bend radius | The minimum cables bending radius should be 38.4mm. | Printed as "The minimum cables bending radius should be 38.4mm." in section 6.2 of JA Solar's PV Bifacial Double-glass Modules Installation Manual (Q/JASO-PMO-015 A/15), a statement for every module type the manual covers. Where: PDF page 18, section 6.2 Cables and Wiring | [2] |
| Max system voltage | 1,500 V | Printed as "The maximum system voltage of JA Solar modules is DC 1500V according to the safety appraisal of the IEC61730." in section 6.1 of JA Solar's PV Bifacial Double-glass Modules Installation Manual (Q/JASO-PMO-015 A/15), one statement for all module types the manual covers. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source. Where: PDF page 17, section 6.1 Electrical Property | [2] [1] |
| Module efficiency | 23 % Provisional | Seller-listed specification; not independently verified. Where: efficiency | [1] |
| Operating temperature | -40 to 85 °C / -40 to 185 °F converted | Printed as "The limit operating temperature should be –40°C (-40°F) and 85°C (185°F)." in section 4.1 of JA Solar's PV Bifacial Double-glass Modules Installation Manual (Q/JASO-PMO-015 A/15), a statement for every module type the manual covers; the recommended ambient temperature is printed separately as –40°C to 40°C. Where: PDF page 7, section 4.1 Installation Position and Working Environment | [2] |
| Temperature coefficient | -0.29 %/°C Provisional | Seller-listed specification; not independently verified. Where: temp-coefficient-pmpp | [1] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Module efficiency needed; Product warranty needed; Power warranty needed; Power temperature coefficient needed; First-year degradation needed; Weight / watt needed.
Not enough comparable data for a score. None of this panel's scored inputs has a documented, sourced value yet. On file but not counted, because it is provisional, warned or has no source: module efficiency, power temperature coefficient.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
A documented panel weight and rated output are required.
Not documented. Undisclosed data scores 0.
Not documented, 0 points: Product warranty, Power warranty, First-year degradation.
Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4
How it worksUnknown: no certification evidence recorded in this data.
Unknown: no warranty facts recorded.
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Archived copy captured on 2026-10-01.
Location: Page header (edition) and Product Supplement, PDF page 22 (scope)
Retrieved Oct 1, 2026
JA Solar's own installation manual for its bifacial double-glass modules, captured 1 October 2026 from jasolar.com; printed as Q/JASO-PMO-015 A/15 in the page header. Its Product Supplement names the applicable module types with power range and dimensions (among them JAM66D45-XXX/LB, JAM72D30-XXX/MB and JAM72D40-XXX/MB), and its load table (an image) also names JAM54D41 MB. It gives series-level mounting methods with test loads, torques, grounding and wiring instructions; it does not establish model ratings. Manufacturer instructions, not independent tests.
Archived copy of a document published by JA Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what JA Solar published. Original address: https://www.jasolar.com/uploadfile/fujian/2024/1120/c86f730ceafbac9.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 18ece5c329c5c784151b322847a7e4f57fea3225de93928797434348460f3da4
Location: Electrical specification table in captured PDF
Retrieved Sep 16, 2026
Linked by the seller for this model; manufacturer revision and applicability need confirmation.
Location: Product listing
Retrieved Sep 16, 2026
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by JA Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what JA Solar published. Original address: https://www.jasolar.com/uploadfile/fujian/2024/1120/c86f730ceafbac9.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 18ece5c329c5c784151b322847a7e4f57fea3225de93928797434348460f3da4
No sourced accessories or replacement parts listed yet.
Manufacturer SKU JAM72D40-595/MB USDC-J/F
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: panels-0.4-personal documented pct: 0 basis: Unknown missing: Module efficiency needed Product warranty needed Power warranty needed Power temperature coefficient needed First-year degradation needed Weight / watt needed criteria: key: efficiency label: Module efficiency value: Unknown unit: Unknown shown: 23 % · not confirmed shown detail: Unknown state: unconfirmed points: 0 ceiling: 26 weight: 26 share: Unknown covered: no missing: yes folded: no reason: not-counted reason text: A value is on file but is not counted: it carries a warning or is not confirmed. note: Not documented. display note: Unknown Sources: [1] key: warranty label: Product warranty value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 21 weight: 21 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: performanceWarranty label: Power warranty value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: powerTemperature label: Power temperature coefficient value: Unknown unit: Unknown shown: -0.29 %/°C · not confirmed shown detail: Unknown state: unconfirmed points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: no reason: not-counted reason text: A value is on file but is not counted: it carries a warning or is not confirmed. note: Not documented. display note: Unknown Sources: [1] key: degradation label: First-year degradation value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: weightPerWatt label: Weight / watt value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 5 weight: 5 share: Unknown covered: no missing: yes folded: no reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: A documented panel weight and rated output are required. display note: Unknown Sources: [1] | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.