Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Greentech Renewables's product image of the JA Solar JAM72D40-590/MB-US on its own store listing.No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Current at max power | 13.09 A Provisional | Seller-listed specification; not independently verified. Where: max-power-current | [1] |
| Short-circuit current | 14.05 A Provisional | Seller-listed specification; not independently verified. Where: short-circuit-current | [1] |
| Voltage at max power | 45.1 V Provisional | Seller-listed specification; not independently verified. Where: max-power-voltage | [1] |
| Open-circuit voltage | 53.9 V Provisional | Seller-listed specification; not independently verified. Where: open-circuit-voltage | [1] |
| Bifacial | yes Provisional | Seller-listed specification; not independently verified. Where: Product category | [1] |
| Cell type | N-Type Provisional | Seller-listed specification; not independently verified. Where: technology | [1] |
| Grounding | There is a grounding hole with 4.2 mm diameter on the edge side closer to the middle of the back frame of the modules.; The recommended torque value is 2.3 N.m.; 12 AWG copper wire can be used as the equipment grounding conductor in conjunction with the grounding bolt. | Printed as "There is a grounding hole with 4.2 mm diameter on the edge side closer to the middle of the back frame of the modules." in section 7.1 of JA Solar's PV Bifacial Double-glass Modules Installation Manual (Q/JASO-PMO-015 A/15), with the other quoted lines from the same section. Section 7.2 allows grounding through an unused mounting hole with a grounding clamp and toothed gasket (nut torque 2.0 N.m~2.2 N.m). Where: PDF page 20, section 7.1 Grounding by Using Grounding Bolt | [2] |
| Front glass | 2.0mm | Printed as "Front Glass/Back Glass 2.0mm/2.0mm" in JA Solar's JAM72D40 MB-US 580-605 n-Type Double Glass Bifacial Modules datasheet (Global-EN-20250627A), captured on September 28, 2026. Read from rendered page 2 (the file has no text layer); the first thickness is the front glass and the second the back glass. Where: Datasheet page 2, MECHANICAL PARAMETERS table, Front Glass/Back Glass row | [3] |
| Clamp torque | 18 to 24 N·m | Printed as "B. Recommended bolt torque range: 18-24N·m." in section 5.2.1 (Modules installed with clamp) of JA Solar's PV Bifacial Double-glass Modules Installation Manual (Q/JASO-PMO-015 A/15); the clamp bolt is M8. Section 5.2.2 (PDF page 11) gives 15-20N·m for M8 screws in mounting holes. Where: PDF page 9, section 5.2.1 Modules installed with clamp, item B | [2] |
| Rear surface | 2.0mm | Printed as "Front Glass/Back Glass 2.0mm/2.0mm" in JA Solar's JAM72D40 MB-US 580-605 n-Type Double Glass Bifacial Modules datasheet (Global-EN-20250627A), captured on September 28, 2026. Read from rendered page 2 (the file has no text layer); the first thickness is the front glass and the second the back glass. Where: Datasheet page 2, MECHANICAL PARAMETERS table, Front Glass/Back Glass row | [3] |
| Dimensions | W 1,134 × L 2,278 × D 35 mm / W 44.65 × L 89.69 × D 1.4 in converted Provisional | Seller-listed specification; not independently verified. Where: Dimensions | [1] |
| Rated power | 590 W Provisional | Seller-listed specification; not independently verified. Where: watts-stc | [1] |
| Series fuse | 30 A Provisional | Seller-listed specification; not independently verified. Where: series-fuse-rating | [1] |
| Cable bend radius | The minimum cables bending radius should be 38.4mm. | Printed as "The minimum cables bending radius should be 38.4mm." in section 6.2 of JA Solar's PV Bifacial Double-glass Modules Installation Manual (Q/JASO-PMO-015 A/15), a statement for every module type the manual covers. Where: PDF page 18, section 6.2 Cables and Wiring | [2] |
| Max system voltage | 1,500 V | Printed as "The maximum system voltage of JA Solar modules is DC 1500V according to the safety appraisal of the IEC61730." in section 6.1 of JA Solar's PV Bifacial Double-glass Modules Installation Manual (Q/JASO-PMO-015 A/15), one statement for all module types the manual covers. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source. Where: PDF page 17, section 6.1 Electrical Property | [2] [1] |
| Module efficiency | 22.8 % Provisional | Seller-listed specification; not independently verified. Where: efficiency | [1] |
| Operating temperature | -40 to 85 °C / -40 to 185 °F converted | Printed as "The limit operating temperature should be –40°C (-40°F) and 85°C (185°F)." in section 4.1 of JA Solar's PV Bifacial Double-glass Modules Installation Manual (Q/JASO-PMO-015 A/15), a statement for every module type the manual covers; the recommended ambient temperature is printed separately as –40°C to 40°C. Where: PDF page 7, section 4.1 Installation Position and Working Environment | [2] |
| Temperature coefficient | -0.29 %/°C Provisional | Seller-listed specification; not independently verified. Where: temp-coefficient-pmpp | [1] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Module efficiency needed; Product warranty needed; Power warranty needed; Power temperature coefficient needed; First-year degradation needed; Weight / watt needed.
Not enough comparable data for a score. None of this panel's scored inputs has a documented, sourced value yet. On file but not counted, because it is provisional, warned or has no source: module efficiency, power temperature coefficient.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
A documented panel weight and rated output are required.
Not documented. Undisclosed data scores 0.
Not documented, 0 points: Product warranty, Power warranty, First-year degradation.
Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4
How it worksUnknown: no warranty facts recorded.
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Archived copy captured on 2026-10-01.
Location: Page header (edition) and Product Supplement, PDF page 22 (scope)
Retrieved Oct 1, 2026
JA Solar's own installation manual for its bifacial double-glass modules, captured 1 October 2026 from jasolar.com; printed as Q/JASO-PMO-015 A/15 in the page header. Its Product Supplement names the applicable module types with power range and dimensions (among them JAM66D45-XXX/LB, JAM72D30-XXX/MB and JAM72D40-XXX/MB), and its load table (an image) also names JAM54D41 MB. It gives series-level mounting methods with test loads, torques, grounding and wiring instructions; it does not establish model ratings. Manufacturer instructions, not independent tests.
Archived copy of a document published by JA Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what JA Solar published. Original address: https://www.jasolar.com/uploadfile/fujian/2024/1120/c86f730ceafbac9.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 18ece5c329c5c784151b322847a7e4f57fea3225de93928797434348460f3da4
Location: Product listing
Retrieved Sep 16, 2026
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Location: Seller-linked document
Retrieved Sep 16, 2026
Linked by the seller for this model; manufacturer revision and applicability need confirmation.
Archived copy of a document published by JA Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what JA Solar published. Original address: https://www.jasolar.com/uploadfile/fujian/2024/1120/c86f730ceafbac9.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 18ece5c329c5c784151b322847a7e4f57fea3225de93928797434348460f3da4
No sourced accessories or replacement parts listed yet.
Manufacturer SKU JAM72D40-590/MB-US
Observed Oct 11, 2026
Product / system scope unresolved. Model JAM72D40-590/MB-US listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under JA Solar, as "JAM72D40-590/MB-US", CEC listing date 2025-12-22. This is an equipment listing, not UL certification or complete-system approval.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: panels-0.4-personal documented pct: 0 basis: Unknown missing: Module efficiency needed Product warranty needed Power warranty needed Power temperature coefficient needed First-year degradation needed Weight / watt needed criteria: key: efficiency label: Module efficiency value: Unknown unit: Unknown shown: 22.8 % · not confirmed shown detail: Unknown state: unconfirmed points: 0 ceiling: 26 weight: 26 share: Unknown covered: no missing: yes folded: no reason: not-counted reason text: A value is on file but is not counted: it carries a warning or is not confirmed. note: Not documented. display note: Unknown Sources: [1] key: warranty label: Product warranty value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 21 weight: 21 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: performanceWarranty label: Power warranty value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: powerTemperature label: Power temperature coefficient value: Unknown unit: Unknown shown: -0.29 %/°C · not confirmed shown detail: Unknown state: unconfirmed points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: no reason: not-counted reason text: A value is on file but is not counted: it carries a warning or is not confirmed. note: Not documented. display note: Unknown Sources: [1] key: degradation label: First-year degradation value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: weightPerWatt label: Weight / watt value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 5 weight: 5 share: Unknown covered: no missing: yes folded: no reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: A documented panel weight and rated output are required. display note: Unknown Sources: [1] | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page