Charged Reviews · Quick reference
JA Solar JAM72D30-535/MB
- Brand
- JA Solar
- Model
- JAM72D30-535/MB
- SKU / part number
- JAM72D30-535/MB Provisional [1]
- Category
- Solar panels
chargedreviews.com/panels/ja-solar-jam72d30-535-mb
Electrical at STC
Temperature and system limits
Cells and construction
Mechanical and connections
- Weight
- 31.8 kg / 70.1 lb converted [1]
- Connectors
- ?
- Cable length
- ?
- Junction box rating
- ?
- Mounting
- ?
- Design load, front
- ?
- Design load, rear
- ?
Installation (from the manual)
Torque
- Clamp or bolt torque
- 18 to 24 N·m [2]
Conductors
- Cable bending radius / connector notes
- The minimum cables bending radius should be 38.4mm. [2]
Clearances and orientation
- Mounting methods and clamp zones
- Inner four holes, mounting rails parallel the long frame: ±2400; Inner four holes, mounting rails cross the long frame: +5400/-2400; Clamps, mounting rails parallel the long frame: ±2400 (72: 450mm≤S≤550mm); Clamps, mounting rails cross the long frame: +5400/-2400 (72: 450mm≤S≤550mm); Mounting by 400mm spaced holes: ±1800; Outer four holes, mounting rails parallel the long frame: ±2400; Outer four holes, mounting rails cross the long frame: +5400/-2400 [2]
Grounding
- Grounding
- There is a grounding hole with 4.2 mm diameter on the edge side closer to the middle of the back frame of the modules.; The recommended torque value is 2.3 N.m.; 12 AWG copper wire can be used as the equipment grounding conductor in conjunction with the grounding bolt. [2]