Electrical at STC

Rated output (STC)
450 W [2] [1]
Module efficiency
22 % [2] [1]
Voltage at max power (Vmp)
33 V [2]
Current at max power (Imp)
13.66 A [2]
Open-circuit voltage (Voc)
38.9 V [2]
Short-circuit current (Isc)
14.55 A [2]
Power tolerance
?

Temperature and system limits

Temperature coefficient, Pmax
-0.29 %/°C [2] [1]
Temperature coefficient, Voc
-0.25 %/°C [2]
Temperature coefficient, Isc
?
Maximum system voltage
1,000 V [2]
Maximum series fuse
?
NOCT / NMOT
?
Rated output at NMOT
?
Operating temperature
?

Cells and construction

Cell technology
N-Type TOPcon [2] [1]
Cell count
?
Bifacial
?
Bifaciality
?
Frame
Anodized aluminium alloy [2]
Front glass
3.2 mm tempered glass with anti-reflective coating [2]
Back cover
?
Panel format
?

Mechanical and connections

Dimensions
W 1,134 × L 1,800 × D 35 mm / W 44.65 × L 70.87 × D 1.4 in converted [2] [1]
Weight
23 kg / 51 lb converted [2]
Connectors
?
Cable length
?
Junction box rating
?
Mounting
?
Design load, front
?
Design load, rear
?

Installation (from the manual)

Conductors

Cable bending radius / connector notes
A minimum bending radius of 60 mm (2.36 in) is required when securing the junction box cables to the racking system. Needs confirmation [3]

Clearances and orientation

Mounting methods and clamp zones
Bolting, Table 3, CS6.1-54TM-H: outer four holes O-A +5400Pa/ -4000Pa*, O-B +5400Pa/ -4000Pa* (*: D-type washer with outer diameter 23mm); inner and middle holes not tested; 6.2.1 Clamp mounting on long side of frame and rails perpendicular to the long side frame, CS6.1-54TM-H: A Range 0-200 mm at +2400/-2400 Pa, 200-650 mm at +3600/-2400 Pa, 300-550 mm at +5400/-3600 Pa, 450-550 mm at +7000/-5400 Pa; 6.2.2 Clamp mounting on short side of frame and rails perpendicular to the long side frame, CS6.1-54TM-H: A Range 200-250 mm at +2400/-2400 Pa; 6.2.3 Clamp mounting on long side of frame and rails parallel to the long side frame, CS6.1-54TM-H: A1 Range 100-600 mm at +4000/-2400 Pa, 450-550 mm at +5400/-2400 Pa Needs confirmation [3]

Grounding

Grounding
GROUNDING METHOD: BOLT + TOOTHED NUT + CUP WASHER.; we recommend using 4-14 mm² (AWG 6-12) copper wire.; Ensure that the cup washer is positioned between the frame and the wire with the concave side up to prevent galvanic corrosion.; The tightening torque is 3-7 Nm (2.2-5.2 ft-lbs). Needs confirmation [3]

Not in the manual: Torque

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

Canadian Solar CS6.1-54TM-450H · CS6.1-54TM-450H

Warranty

Product warranty?
Power warranty term?
First-year degradation?
Annual degradation after year one?
Warranted final output?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?

Certifications and listings

UL 61730?
UL 1703?
IEC 61215?
IEC 61730?
IEC 62804?
CEC listing?

Documents and sources

  1. Canadian Solar 450W 108 Half-Cell 1500V TOPcon BLK/BLK Solar Panel, CS6.1-54TM-450H Product page · Checked Sep 16, 2026 https://www.greentechrenewables.com/product/canadian-solar-450w-108-half-cell-1500v-topcon-blkblk-solar-panel-cs61-54tm-450h
  2. TOPHiKu6 (All-Black) CS6.1-54TM-435|440|445|450|455|460|465H datasheet, North America Manufacturer datasheet · Revision V1.4C25_F23_D1_NA (March 2026) · Checked Sep 25, 2026 https://static.csisolar.com/wp-content/uploads/sites/3/2026/03/16103959/CS-Datasheet-TOPHiKu6_All-Black_CS6.1-54TM-H_v1.4C25_F23_D1_NA.pdf
  3. Canadian Solar Installation Manual of Photovoltaic Module (international (IEC) edition, EN-Rev IM/GN-EN/3.1) Installation manual, international (IEC) edition · Revision EN-Rev IM/GN-EN/3.1 · Revised 2025-11 · Checked Oct 1, 2026 https://static.csisolar.com/wp-content/uploads/sites/2/2025/11/19131423/CS_Installation-Manual_PV-Modules_EN-v3.1-EN.pdf

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/panels/canadian-solar-cs6-1-54tm-450hSome links pay us a commission. That does not affect what we record.