Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Canadian Solar CS6.1-54TM-450H/B image published by GreenTech Renewables on its listing for this product. Distributor photo, not a manufacturer-issued image.No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Current at max power | 13.66 A Provisional | Seller-listed specification; not independently verified. Where: max-power-current | [1] |
| Short-circuit current | 14.55 A Provisional | Seller-listed specification; not independently verified. Where: short-circuit-current | [1] |
| Voltage at max power | 33 V Provisional | Seller-listed specification; not independently verified. Where: max-power-voltage | [1] |
| Open-circuit voltage | 38.9 V Provisional | Seller-listed specification; not independently verified. Where: open-circuit-voltage | [1] |
| Cell type | N-Type TOPCon Provisional | Seller-listed specification; not independently verified. Where: technology | [1] |
| Grounding | GROUNDING METHOD: BOLT + TOOTHED NUT + CUP WASHER.; we recommend using 4-14 mm² (AWG 6-12) copper wire.; Ensure that the cup washer is positioned between the frame and the wire with the concave side up to prevent galvanic corrosion.; The tightening torque is 3-7 Nm (2.2-5.2 ft-lbs). Check note | From the international (IEC) edition; the North American edition may differ. The value comes from Canadian Solar's international (IEC) edition installation manual (EN-Rev IM/GN-EN/3.1, November 2025); this record is a North American model, and Canadian Solar's North American edition, which does not name this series, may print a different value. Printed as "GROUNDING METHOD: BOLT + TOOTHED NUT + CUP WASHER." in section 5.2 (Grounding) of Canadian Solar's Installation Manual of Photovoltaic Module, international (IEC) edition (EN-Rev IM/GN-EN/3.1, November 2025), with the other quoted lines from the same section, a general instruction for the modules the manual covers. The manual's section 1 says "This manual is valid for the solar modules listed in the table below." and its table lists CS6.1-54TM-xxxH. The kit is an M5 stainless steel cap bolt, flat washer, cup washer and toothed nut on the pre-drilled grounding hole, and Canadian Solar does not provide grounding hardware.Where: PDF page 14, section 5.2 Grounding | [2] |
| Weight | 23 kg / 51 lb converted | Printed as "Weight 50.7 Lbs." in the Canadian Solar 450W 108 Half-Cell TOPCon BLK/BLK Solar Panel - B Grade, CS6.1-54TM-450H/B; the maker prints pounds only, converted to kilograms. Revised on 30 September 2026: The maker prints this weight in pounds only; the stored kilograms were an unlabeled conversion, now labeled with the printed pounds kept (Project Manager, September 30, 2026). Where: Greentech Renewables product page, specification table, Weight SourcesConverted: 50.7 lb x 0.45359237 kg/lb, rounded to 0.01 kg | [1] |
| Dimensions | W 1,134 × L 1,800 × D 35 mm / W 44.65 × L 70.87 × D 1.4 in converted Provisional | Seller-listed specification; not independently verified. Where: Dimensions | [1] |
| Rated power | 450 W Provisional | Seller-listed specification; not independently verified. Where: watts-stc | [1] |
| Series fuse | 25 A Provisional | Seller-listed specification; not independently verified. Where: series-fuse-rating | [1] |
| Mounting methods | Bolting, Table 3, CS6.1-54TM-H: outer four holes O-A +5400Pa/ -4000Pa*, O-B +5400Pa/ -4000Pa* (*: D-type washer with outer diameter 23mm); inner and middle holes not tested; 6.2.1 Clamp mounting on long side of frame and rails perpendicular to the long side frame, CS6.1-54TM-H: A Range 0-200 mm at +2400/-2400 Pa, 200-650 mm at +3600/-2400 Pa, 300-550 mm at +5400/-3600 Pa, 450-550 mm at +7000/-5400 Pa; 6.2.2 Clamp mounting on short side of frame and rails perpendicular to the long side frame, CS6.1-54TM-H: A Range 200-250 mm at +2400/-2400 Pa; 6.2.3 Clamp mounting on long side of frame and rails parallel to the long side frame, CS6.1-54TM-H: A1 Range 100-600 mm at +4000/-2400 Pa, 450-550 mm at +5400/-2400 Pa Check note | From the international (IEC) edition; the North American edition may differ. The value comes from Canadian Solar's international (IEC) edition installation manual (EN-Rev IM/GN-EN/3.1, November 2025); this record is a North American model, and Canadian Solar's North American edition, which does not name this series, may print a different value. Printed as "CS6.1-54TM-H / / / / +5400Pa/ -4000Pa* +5400Pa/ -4000Pa*" in Table 3 (Approved bolting methods) of Canadian Solar's Installation Manual of Photovoltaic Module, international (IEC) edition (EN-Rev IM/GN-EN/3.1, November 2025); the clamp rows quoted here are the CS6.1-54TM-H rows of the tables in sections 6.2.1 to 6.2.3. The load column for each range was read from rendered pages 19, 24, 26 and 28 (the text layer runs the table cells together). All loads are test loads; the manual says a safety factor of 1.5 gives the design load. Further methods naming this series (more clamp layouts, insertion systems or single-axis trackers) are on PDF pages 31 to 39.Where: PDF page 19 (Table 3, approved bolting methods), PDF page 24 (section 6.2.1), PDF page 26 (section 6.2.2) and PDF page 28 (section 6.2.3) | [2] |
| Cable bend radius | A minimum bending radius of 60 mm (2.36 in) is required when securing the junction box cables to the racking system. Check note | From the international (IEC) edition; the North American edition may differ. The value comes from Canadian Solar's international (IEC) edition installation manual (EN-Rev IM/GN-EN/3.1, November 2025); this record is a North American model, and Canadian Solar's North American edition, which does not name this series, may print a different value. Printed as "A minimum bending radius of 60 mm (2.36 in) is required when securing the junction box cables to the racking system." in section 5.1 of Canadian Solar's Installation Manual of Photovoltaic Module, international (IEC) edition (EN-Rev IM/GN-EN/3.1, November 2025), a general instruction for the modules the manual covers. The manual's section 1 says "This manual is valid for the solar modules listed in the table below." and its table lists CS6.1-54TM-xxxH.Where: PDF page 13, section 5.1 Module Wiring, Cable and Connector Protection | [2] |
| Max system voltage | 1,500 V Provisional | Seller-listed specification; not independently verified. Where: max-operating-voltage | [1] |
| Module efficiency | 22 % Provisional | Seller-listed specification; not independently verified. Where: efficiency | [1] |
| Temperature coefficient | -0.29 %/°C Provisional | Seller-listed specification; not independently verified. Where: temp-coefficient-pmpp | [1] |
| Voc temperature coefficient | -0.25 %/°C | Printed as "Temperature Coefficient (Voc) -0.25 % / °C" in View. The datasheet is the model family's sheet this record already cites; it prints one Voc temperature coefficient for every model it lists. Where: Specification table, temperature coefficients | [3] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Module efficiency needed; Product warranty needed; Power warranty needed; Power temperature coefficient needed; First-year degradation needed; Weight / watt needed.
Not enough comparable data for a score. None of this panel's scored inputs has a documented, sourced value yet. On file but not counted, because it is provisional, warned or has no source: module efficiency, power temperature coefficient, weight / watt.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
A documented panel weight and rated output are required.
A value is on file but is not counted: it carries a warning or is not confirmed.
Not documented, 0 points: Product warranty, Power warranty, First-year degradation.
Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4
How it worksUnknown: no certification evidence recorded in this data.
Unknown: no warranty facts recorded.
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Archived copy captured on 2026-10-01.
Location: PDF page 3, section 1 General Information (scope table)
Retrieved Oct 1, 2026
Canadian Solar's own installation manual for its crystalline silicon modules, international (IEC) edition, captured 1 October 2026 from static.csisolar.com as still linked under Installation Manuals (Installation Manual_PV Modules_EN) on the CSI Solar global downloads page. Revision as printed: EN-Rev IM/GN-EN/3.1, Copyright November 2025. Its section 1 scope table names, among others, CS6R-xxxMS-HL and CS6.1-54TM-xxxH, which the newer international edition (EN-Rev IM/GN-EU/3.3, July 2026) no longer lists, so this older edition is the newest that names them. This is the international (IEC) edition; the records it is attached to are North American models, and Canadian Solar's North American edition may differ (standards, loads, fuse, system voltage, wiring rules); its U.S. edition (US-Rev IM/GN-EN/3.3) does not name these series. Series-level instructions and test-load tables, not model ratings. Manufacturer instructions, not independent tests.
Archived copy of a document published by Canadian Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Canadian Solar published. Original address: https://static.csisolar.com/wp-content/uploads/sites/2/2025/11/19131423/CS_Installation-Manual_PV-Modules_EN-v3.1-EN.pdf. Copyright and takedown
Printed revision date: 2025-11
Embedded dates are file metadata, not independent proof of publication.
SHA-256: d7e3862cb6aa5508234c7bbcd697b52b9a476d15c6b49a3bcc6197d5cfc66a18
Linked from the GreenTech Renewables product page with link text "View".
Location: ZZ084000133_DS.pdf
Retrieved Sep 18, 2026
Original PDF preserved byte for byte, found linked from the GreenTech Renewables listing https://www.greentechrenewables.com/product/canadian-solar-460w-108-half-cell-1500v-topcon-blkblk-solar-panel-cs61-54tm-460h. The revision is whatever was published at this URL on the access date; exact variant coverage inside the document was not separately verified and no later revision was checked.
SHA-256: d49074e6b88a71346b2377ee26918dcb286ecf32520fad4432d2900f57b1d46c
Archived copy of a document published by cdn.myced.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what cdn.myced.com published. Original address: https://cdn.myced.com/images/Products/ZZ0000/ZZ0840/00000/ZZ084000133_DS.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: d49074e6b88a71346b2377ee26918dcb286ecf32520fad4432d2900f57b1d46c
Location: Product listing
Retrieved Sep 16, 2026
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by cdn.myced.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what cdn.myced.com published. Original address: https://cdn.myced.com/images/Products/ZZ0000/ZZ0840/00000/ZZ084000133_DS.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: d49074e6b88a71346b2377ee26918dcb286ecf32520fad4432d2900f57b1d46c
Archived copy of a document published by Canadian Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Canadian Solar published. Original address: https://static.csisolar.com/wp-content/uploads/sites/2/2025/11/19131423/CS_Installation-Manual_PV-Modules_EN-v3.1-EN.pdf. Copyright and takedown
Printed revision date: 2025-11
Embedded dates are file metadata, not independent proof of publication.
SHA-256: d7e3862cb6aa5508234c7bbcd697b52b9a476d15c6b49a3bcc6197d5cfc66a18
No sourced accessories or replacement parts listed yet.
Manufacturer SKU CS6.1-54TM-450H/B
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: panels-0.4-personal documented pct: 0 basis: Unknown missing: Module efficiency needed Product warranty needed Power warranty needed Power temperature coefficient needed First-year degradation needed Weight / watt needed criteria: key: efficiency label: Module efficiency value: Unknown unit: Unknown shown: 22 % · not confirmed shown detail: Unknown state: unconfirmed points: 0 ceiling: 26 weight: 26 share: Unknown covered: no missing: yes folded: no reason: not-counted reason text: A value is on file but is not counted: it carries a warning or is not confirmed. note: Not documented. display note: Unknown Sources: [1] key: warranty label: Product warranty value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 21 weight: 21 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: performanceWarranty label: Power warranty value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: powerTemperature label: Power temperature coefficient value: Unknown unit: Unknown shown: -0.29 %/°C · not confirmed shown detail: Unknown state: unconfirmed points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: no reason: not-counted reason text: A value is on file but is not counted: it carries a warning or is not confirmed. note: Not documented. display note: Unknown Sources: [1] key: degradation label: First-year degradation value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: weightPerWatt label: Weight / watt value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 5 weight: 5 share: Unknown covered: no missing: yes folded: no reason: not-counted reason text: A value is on file but is not counted: it carries a warning or is not confirmed. note: A documented panel weight and rated output are required. display note: Unknown Sources: [1] | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.