Key specs

Units
SKU
BBPV-12-120
Official datasheet
Sources

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Header: 'Model: BBPV-12-120'

Documented

Rated output (STC)
120 W
Official datasheet
Sources

STC: Irradiance 1000W/m2, AM1.5 spectrum, module temperature 25 degC

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Electrical Characteristics -> Maximum Power (Pmax)

Documented

Module efficiency
23 %
Official datasheet
Sources

Datasheet states '23% module efficiency' (overview badge: '23% Module Efficiency')

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Datasheet overview badge / description

Documented

Voltage at max power (Vmp)
19.08 V
Official datasheet
Sources

STC: Irradiance 1000W/m2, AM1.5 spectrum, module temperature 25 degC

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Electrical Characteristics -> Voltage at Pmax (Vmp)

Documented

Current at max power (Imp)
6.3 A
Official datasheet
Sources

STC: Irradiance 1000W/m2, AM1.5 spectrum, module temperature 25 degC

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Electrical Characteristics -> Current at Pmax (Imp)

Documented

Open-circuit voltage (Voc)
22.35 V
Official datasheet
Sources

STC: Irradiance 1000W/m2, AM1.5 spectrum, module temperature 25 degC

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Electrical Characteristics -> Open-circuit voltage (Voc)

Documented

Short-circuit current (Isc)
6.7 A
Official datasheet
Sources

STC: Irradiance 1000W/m2, AM1.5 spectrum, module temperature 25 degC

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Electrical Characteristics -> Short-circuit current (Isc)

Documented

Power temperature coefficient
-(0.5±0.05)%/°C
Official datasheet
Sources

Exact wording: '-(0.5±0.05)%/degC'; value copied verbatim as a tolerance range, not a single number Printed as a tolerance band, so the datasheet wording is stored instead of a single number.

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Electrical Characteristics -> Temperature coefficient of power

Documented

Maximum system voltage
1,000 V
Official datasheet
Sources

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Electrical Characteristics -> Maximum system voltage

Documented

All specs13
Rated output (STC)
120 W
Official datasheet
Sources

STC: Irradiance 1000W/m2, AM1.5 spectrum, module temperature 25 degC

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Electrical Characteristics -> Maximum Power (Pmax)

Documented

Module efficiency
23 %
Official datasheet
Sources

Datasheet states '23% module efficiency' (overview badge: '23% Module Efficiency')

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Datasheet overview badge / description

Documented

Voltage at max power (Vmp)
19.08 V
Official datasheet
Sources

STC: Irradiance 1000W/m2, AM1.5 spectrum, module temperature 25 degC

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Electrical Characteristics -> Voltage at Pmax (Vmp)

Documented

Current at max power (Imp)
6.3 A
Official datasheet
Sources

STC: Irradiance 1000W/m2, AM1.5 spectrum, module temperature 25 degC

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Electrical Characteristics -> Current at Pmax (Imp)

Documented

Open-circuit voltage (Voc)
22.35 V
Official datasheet
Sources

STC: Irradiance 1000W/m2, AM1.5 spectrum, module temperature 25 degC

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Electrical Characteristics -> Open-circuit voltage (Voc)

Documented

Short-circuit current (Isc)
6.7 A
Official datasheet
Sources

STC: Irradiance 1000W/m2, AM1.5 spectrum, module temperature 25 degC

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Electrical Characteristics -> Short-circuit current (Isc)

Documented

Power temperature coefficient
-(0.5±0.05)%/°C
Official datasheet
Sources

Exact wording: '-(0.5±0.05)%/degC'; value copied verbatim as a tolerance range, not a single number Printed as a tolerance band, so the datasheet wording is stored instead of a single number.

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Electrical Characteristics -> Temperature coefficient of power

Documented

Maximum system voltage
1,000 V
Official datasheet
Sources

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Electrical Characteristics -> Maximum system voltage

Documented

Published claims and calculations, not independent test results.

Documents

2 on file
  • PDF
    BBPV-12-120 Data SheetOfficialBattle Born BatteriesOfficial datasheet
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Electrical Characteristics / Specifications tables, page 2

    Retrieved

    SHA-256: bed0c3eeac22485afe1372717fec619b37b167d900205cf1ab5038a93c10db9f

    Open
  • WEB
    Battle Born Elite 120WOfficialBattle Born BatteriesOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Specifications table

    Retrieved

    SHA-256: 8bf21e020288bf6f954dbc9e547cc808f88f5ef7471a1eea624ec9365af8e35b

    Open

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • WEB
    Battle Born Batteries product page: Battle Born Elite 120W 12V Rigid Solar PanelBattle Born BatteriesOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Matched to the catalog record on an exact manufacturer SKU match.

    Location: Store variant SKU BBPV-12-120; product handle elite-120w-12v-rigid-solar-panel

    Retrieved

    Manufacturer-operated store product page, captured byte for byte with a plain HTTPS GET and a desktop user agent. It establishes what the manufacturer published at this URL on the access date for the exact store variant named in the locator: the specification table, the photo and the documents linked from the page. Marketing text, certification wording and stock state on the page remain manufacturer claims that were not independently verified, and no value on it was applied to any other model.

    Open

Archived documents

Download

Archived copy of a document published by Battle Born Batteries. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 6.60 MB

Archived copy, unaltered, kept as a record of what Battle Born Batteries published. Original address: https://battlebornbatteries.com/cdn/shop/files/BBPV-12-120_Data_Sheet.pdf?v=16301000592255080806. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Embedded dates are file metadata, not independent proof of publication.

SHA-256: bed0c3eeac22485afe1372717fec619b37b167d900205cf1ab5038a93c10db9f

Submit a document

Warranty

Warranted final output
80.68 %
Official datasheet
Sources

Guaranteed Power under the Solar Linear Warranty chart at the 25 Years mark; chart also shows 97% at the start and 94.28 / 90.88 / 87.48 / 84.08% at 5 / 10 / 15 / 20 years

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Performance Warranty chart, 25 Years column

Documented

Product warranty
10 years
Official datasheet
Sources

Stated as '10-year workmanship warranty' and '10 Year Product Warranty'

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Key Features / '10 Year Product Warranty'

Documented

Power warranty
25 years
Official datasheet
Sources

Stated as '25-year linear performance warranty'

Official datasheet: BBPV-12-120 Data Sheet Checked

Location: Key Features / '25 Year Performance Warranty'

Documented

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

47/10068% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Power temperature coefficient needed; First-year degradation needed.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Power temperature coefficient-(0.5±0.05)%/°C · not confirmed0.0 / 16.0

Exact wording: '-(0.5±0.05)%/degC'; value copied verbatim as a tolerance range, not a single number Printed as a tolerance band, so the datasheet wording is stored instead of a single number.

A value is on file but is not counted: it carries a warning or is not confirmed.

Official datasheet: BBPV-12-120 Data Sheet Checked

Not documented, 0 points: First-year degradation.

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
BBPV-12-120

Manufacturer SKU BBPV-12-120 · US market

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.