Charged Reviews

Quick reference

EG4 9K BTU Mini-Split Air Conditioner / Heat Pump R32 (EG4MSAC9V1)

Model: EG4MSAC9V1 · SKU: EG4MSAC9V1

Prepared Nov 12, 2026

Common specifications

Cooling capacity
9,000 BTU/hSource [1, 2, 3]
Heating capacity
9,500 BTU/hSource [1, 2]
SEER2
25Source [1, 2]
EER2
14.5Source [1, 2]
HSPF2
10.5Source [1, 2]
Refrigerant
R32Source [1, 2]
Refrigerant GWPNot documented
Voltage
115 VSource [1, 2]
Solar input voltageNot documented
Maximum solar inputNot documented
AHRI certificate numberNot documented
Indoor noiseNot documented
Outdoor noise
52 dBSource [1, 2, 3]
Indoor unit model
DGA3-09KR2Source [1, 2]
Outdoor unit model
DWA4-09KR2Source [1, 2]
Operating temperatureNot documented
Rated current (as printed)Not documented
Power inputNot documented
Dimensions
323 D × 802 W × 564 H mm12.7 D × 31.6 W × 22.2 H in convertedSource [1, 2]
Weight
28.5 kg62.8 lb convertedSource [1, 2]
CommunicationsNot documented
Certifications (as printed)Not documented
Enclosure volume146.1 L** Calculated from recorded external dimensions
Warranty term
5 yearsSource [1, 2]

All recorded specifications

Cooling capacity
9,000 BTU/hDocumented claim
Conditions

Printed as "NOMINAL CAPACITY 9,000 BTU/h 12,000 BTU/h" under RATED COOLING (the manual's table prints the 9K and 12K systems side by side; the first figure is the 9K system's); the spec sheet prints the same.

Location: Manual section 1, RATED COOLING, 9K SYSTEM

Printed as "NOMINAL CAPACITY 9,000 BTU/h 12,000 BTU/h" under RATED COOLING (the manual's table prints the 9K and 12K systems side by side; the first figure is the 9K system's); the spec sheet prints the same.

Location: Manual section 1, RATED COOLING, 9K SYSTEM

[1, 2, 3]
Dimensions
323 D × 802 W × 564 H mm12.7 D × 31.6 W × 22.2 H in convertedDocumented claim
Conditions

The outdoor unit (DWA4-09KR2), printed as "31.6 x 12.7 x 22.2 in. (802 x 323 x 564 mm)", one value for both the 9K and 12K outdoor units. The indoor unit (DGA3-09KR2) is printed separately under INDOOR UNIT DATA (page 2, PDF page 4) as "33.07 x 8.07 x 11.61 in. (840 x 205 x 295 mm)", also one value for both systems. The spec sheet prints the same figures.

Location: Manual section 1, OUTDOOR UNIT DATA, UNIT DIMENSIONS (W×D×H) (page 1, PDF page 3)

The outdoor unit (DWA4-09KR2), printed as "31.6 x 12.7 x 22.2 in. (802 x 323 x 564 mm)", one value for both the 9K and 12K outdoor units. The indoor unit (DGA3-09KR2) is printed separately under INDOOR UNIT DATA (page 2, PDF page 4) as "33.07 x 8.07 x 11.61 in. (840 x 205 x 295 mm)", also one value for both systems. The spec sheet prints the same figures.

Location: Manual section 1, OUTDOOR UNIT DATA, UNIT DIMENSIONS (W×D×H) (page 1, PDF page 3)

[1, 2]
EER2
14.5Documented claim
Conditions

Printed as "EER2 14.5 12.6" (the manual's table prints the 9K and 12K systems side by side; the first figure is the 9K system's). Manufacturer claim.

Location: Manual section 1, RATED COOLING, 9K SYSTEM

Printed as "EER2 14.5 12.6" (the manual's table prints the 9K and 12K systems side by side; the first figure is the 9K system's). Manufacturer claim.

Location: Manual section 1, RATED COOLING, 9K SYSTEM

[1, 2]
Heating capacity
9,500 BTU/hDocumented claim
Conditions

Printed as "NOMINAL CAPACITY 9,500 BTU/h 12,000 BTU/h" under RATED HEATING (the manual's table prints the 9K and 12K systems side by side; the first figure is the 9K system's). EG4's product page prints "Cooling/Heating Capacity: 9,000 BTU/h"; the manual's 9,500 BTU/h is recorded and the page value is kept here.

Location: Manual section 1, RATED HEATING, 9K SYSTEM

Printed as "NOMINAL CAPACITY 9,500 BTU/h 12,000 BTU/h" under RATED HEATING (the manual's table prints the 9K and 12K systems side by side; the first figure is the 9K system's). EG4's product page prints "Cooling/Heating Capacity: 9,000 BTU/h"; the manual's 9,500 BTU/h is recorded and the page value is kept here.

Location: Manual section 1, RATED HEATING, 9K SYSTEM

[1, 2]
HSPF2
10.5Documented claim
Conditions

Printed as "HSPF2-4 10.5 9.7" (the manual's table prints the 9K and 12K systems side by side; the first figure is the 9K system's); HSPF2 for climate region 4. Manufacturer claim.

Location: Manual section 1, RATED HEATING, 9K SYSTEM

Printed as "HSPF2-4 10.5 9.7" (the manual's table prints the 9K and 12K systems side by side; the first figure is the 9K system's); HSPF2 for climate region 4. Manufacturer claim.

Location: Manual section 1, RATED HEATING, 9K SYSTEM

[1, 2]
Indoor unit model
DGA3-09KR2Documented claim
Conditions

Printed on the cover as "INDOOR MODEL #: DGA3-09KR2 AND DGA3-12KR2" and as the indoor unit table's column heads.

Location: Manual cover and section 1, INDOOR UNIT DATA

Printed on the cover as "INDOOR MODEL #: DGA3-09KR2 AND DGA3-12KR2" and as the indoor unit table's column heads.

Location: Manual cover and section 1, INDOOR UNIT DATA

[1, 2]
Outdoor noise
52 dBDocumented claim
Conditions

Printed as "SOUND PRESSURE (HI/MED/LO) 52 dB(A)" for both outdoor units; EG4 prints no measuring distance.

Location: Manual section 1, OUTDOOR UNIT DATA

Printed as "SOUND PRESSURE (HI/MED/LO) 52 dB(A)" for both outdoor units; EG4 prints no measuring distance.

Location: Manual section 1, OUTDOOR UNIT DATA

[1, 2, 3]
Outdoor unit model
DWA4-09KR2Documented claim
Conditions

Printed on the cover as "OUDOOR MODEL #: DWA4-09KR2 AND DWA4-12KR2" (EG4's spelling) and as the outdoor unit table's column heads.

Location: Manual cover and section 1, OUTDOOR UNIT DATA

Printed on the cover as "OUDOOR MODEL #: DWA4-09KR2 AND DWA4-12KR2" (EG4's spelling) and as the outdoor unit table's column heads.

Location: Manual cover and section 1, OUTDOOR UNIT DATA

[1, 2]
Refrigerant
R32Documented claim
Conditions

Printed as "REFRIGERANT R32/21.2 oz. (0.63 L) R32/27.5 oz. (0.81 L)"; the 9K system's charge is R32/21.2 oz. (0.63 L).

Location: Manual section 1, SYSTEM DATA

Printed as "REFRIGERANT R32/21.2 oz. (0.63 L) R32/27.5 oz. (0.81 L)"; the 9K system's charge is R32/21.2 oz. (0.63 L).

Location: Manual section 1, SYSTEM DATA

[1, 2]
SEER2
25Documented claim
Conditions

Printed as "SEER2 25 22.5" (the manual's table prints the 9K and 12K systems side by side; the first figure is the 9K system's). Manufacturer claim.

Location: Manual section 1, RATED COOLING, 9K SYSTEM

Printed as "SEER2 25 22.5" (the manual's table prints the 9K and 12K systems side by side; the first figure is the 9K system's). Manufacturer claim.

Location: Manual section 1, RATED COOLING, 9K SYSTEM

[1, 2]
Voltage
115 VDocumented claim
Conditions

Printed as "RATED VOLTAGE 115 VAC" for both systems, with "FREQUENCY 60 Hz".

Location: Manual section 1, ELECTRICAL

Printed as "RATED VOLTAGE 115 VAC" for both systems, with "FREQUENCY 60 Hz".

Location: Manual section 1, ELECTRICAL

[1, 2]
Weight
28.5 kg62.8 lb convertedDocumented claim
Conditions

The outdoor unit's (DWA4-09KR2) net weight, printed as "62.9/73.9 lbs. (28.5/33.5 kg)" (net/gross), one value for both the 9K and 12K outdoor units. The indoor unit (DGA3-09KR2) is printed separately under INDOOR UNIT DATA (page 2, PDF page 4) as "UNIT/PACKAGED WEIGHT 20.9/26.0 lbs. (9.5/11.8 kg)". The spec sheet prints the same figures.

Location: Manual section 1, OUTDOOR UNIT DATA, NET/GROSS WEIGHT (page 1, PDF page 3)

The outdoor unit's (DWA4-09KR2) net weight, printed as "62.9/73.9 lbs. (28.5/33.5 kg)" (net/gross), one value for both the 9K and 12K outdoor units. The indoor unit (DGA3-09KR2) is printed separately under INDOOR UNIT DATA (page 2, PDF page 4) as "UNIT/PACKAGED WEIGHT 20.9/26.0 lbs. (9.5/11.8 kg)". The spec sheet prints the same figures.

Location: Manual section 1, OUTDOOR UNIT DATA, NET/GROSS WEIGHT (page 1, PDF page 3)

[1, 2]

Warranty

Warranty term
5 yearsDocumented claim
Conditions

Printed as "LIMITED WARRANTY* 5-year limited warranty"; coverage terms are set by EG4's warranty policy, which was not captured.

Location: Manual section 1, WARRANTY

Printed as "LIMITED WARRANTY* 5-year limited warranty"; coverage terms are set by EG4's warranty policy, which was not captured.

Location: Manual section 1, WARRANTY

[1, 2]

Certificate records

No records documented.

Sources and revisions

  1. EG4 9K & 12K Mini-Split R32 user manual, version 1.0.1 (outdoor DWA4-09KR2 and DWA4-12KR2, indoor DGA3-09KR2 and DGA3-12KR2)Official user manual · Checked https://eg4electronics.com/wp-content/uploads/2025/10/EG4-9k-12k-BTU-Mini-Split-Air-Conditioner-Heat-Pump-R32-User-Manual.pdf
  2. EG4 9K & 12K AC Mini-Split R32 spec sheet, version 1.0.1Official document · Checked https://eg4electronics.com/wp-content/uploads/2025/10/EG4-9k-12k-BTU-Mini-Split-Air-Conditioner-Heat-Pump-R32-Spec-Sheet.pdf
  3. EG4 Electronics product page: EG4 9K BTU Mini-Split Air Conditioner / Heat Pump R32 (SKU EG4MSAC9V1)Official product page · Checked https://eg4electronics.com/categories/high-efficiency-appliances/eg4-9k-btu-mini-split-air-conditioner-heat-pump-r32/