Charged Reviews
Quick reference
EG4 12K BTU Mini-Split Air Conditioner / Heat Pump R32 (EG4MSAC12V1)
Model: EG4MSAC12V1 · SKU: EG4MSAC12V1
Prepared Nov 12, 2026

Common specifications
| Cooling capacity | 12,000 BTU/hSource [1, 2, 3] |
|---|---|
| Heating capacity | 12,000 BTU/hSource [1, 2] |
| SEER2 | 22.5Source [1, 2] |
| EER2 | 12.6Source [1, 2] |
| HSPF2 | 9.7Source [1, 2] |
| Refrigerant | R32Source [1, 2] |
| Refrigerant GWP | Not documented |
| Voltage | 115 VSource [1, 2] |
| Solar input voltage | Not documented |
| Maximum solar input | Not documented |
| AHRI certificate number | Not documented |
| Indoor noise | Not documented |
| Outdoor noise | 52 dBSource [1, 2, 3] |
| Indoor unit model | DGA3-12KR2Source [1, 2] |
| Outdoor unit model | DWA4-12KR2Source [1, 2] |
| Operating temperature | Not documented |
| Rated current (as printed) | Not documented |
| Power input | Not documented |
| Dimensions | |
| Weight | |
| Communications | Not documented |
| Certifications (as printed) | Not documented |
| Enclosure volume | 146.1 L** Calculated from recorded external dimensions |
| Warranty term | 5 yearsSource [1, 2] |
All recorded specifications
| Cooling capacity | 12,000 BTU/hDocumented claim ConditionsPrinted as "NOMINAL CAPACITY 9,000 BTU/h 12,000 BTU/h" under RATED COOLING (the manual's table prints the 9K and 12K systems side by side; the second figure is the 12K system's); the spec sheet prints the same. Location: Manual section 1, RATED COOLING, 12K SYSTEM Printed as "NOMINAL CAPACITY 9,000 BTU/h 12,000 BTU/h" under RATED COOLING (the manual's table prints the 9K and 12K systems side by side; the second figure is the 12K system's); the spec sheet prints the same. Location: Manual section 1, RATED COOLING, 12K SYSTEM Official user manual · EG4 9K & 12K Mini-Split R32 user manual, version 1.0.1 (outdoor DWA4-09KR2 and DWA4-12KR2, indoor DGA3-09KR2 and DGA3-12KR2)Official document · EG4 9K & 12K AC Mini-Split R32 spec sheet, version 1.0.1Official product page · EG4 Electronics product page: EG4 12K BTU Mini-Split Air Conditioner / Heat Pump R32 (SKU EG4MSAC12V1) [1, 2, 3] |
|---|---|
| Dimensions | 323 D × 802 W × 564 H mm12.7 D × 31.6 W × 22.2 H in convertedDocumented claim ConditionsThe outdoor unit (DWA4-12KR2), printed as "31.6 x 12.7 x 22.2 in. (802 x 323 x 564 mm)", one value for both the 9K and 12K outdoor units. The indoor unit (DGA3-12KR2) is printed separately under INDOOR UNIT DATA (page 2, PDF page 4) as "33.07 x 8.07 x 11.61 in. (840 x 205 x 295 mm)", also one value for both systems. The spec sheet prints the same figures. Location: Manual section 1, OUTDOOR UNIT DATA, UNIT DIMENSIONS (W×D×H) (page 1, PDF page 3) The outdoor unit (DWA4-12KR2), printed as "31.6 x 12.7 x 22.2 in. (802 x 323 x 564 mm)", one value for both the 9K and 12K outdoor units. The indoor unit (DGA3-12KR2) is printed separately under INDOOR UNIT DATA (page 2, PDF page 4) as "33.07 x 8.07 x 11.61 in. (840 x 205 x 295 mm)", also one value for both systems. The spec sheet prints the same figures. Location: Manual section 1, OUTDOOR UNIT DATA, UNIT DIMENSIONS (W×D×H) (page 1, PDF page 3) Official user manual · EG4 9K & 12K Mini-Split R32 user manual, version 1.0.1 (outdoor DWA4-09KR2 and DWA4-12KR2, indoor DGA3-09KR2 and DGA3-12KR2)Official document · EG4 9K & 12K AC Mini-Split R32 spec sheet, version 1.0.1 [1, 2] |
| EER2 | 12.6Documented claim ConditionsPrinted as "EER2 14.5 12.6" (the manual's table prints the 9K and 12K systems side by side; the second figure is the 12K system's). Manufacturer claim. Location: Manual section 1, RATED COOLING, 12K SYSTEM Printed as "EER2 14.5 12.6" (the manual's table prints the 9K and 12K systems side by side; the second figure is the 12K system's). Manufacturer claim. Location: Manual section 1, RATED COOLING, 12K SYSTEM Official user manual · EG4 9K & 12K Mini-Split R32 user manual, version 1.0.1 (outdoor DWA4-09KR2 and DWA4-12KR2, indoor DGA3-09KR2 and DGA3-12KR2)Official document · EG4 9K & 12K AC Mini-Split R32 spec sheet, version 1.0.1 [1, 2] |
| Heating capacity | 12,000 BTU/hDocumented claim ConditionsPrinted as "NOMINAL CAPACITY 9,500 BTU/h 12,000 BTU/h" under RATED HEATING (the manual's table prints the 9K and 12K systems side by side; the second figure is the 12K system's); the product page prints "Cooling/Heating Capacity: 12,000 BTU/h". Location: Manual section 1, RATED HEATING, 12K SYSTEM Printed as "NOMINAL CAPACITY 9,500 BTU/h 12,000 BTU/h" under RATED HEATING (the manual's table prints the 9K and 12K systems side by side; the second figure is the 12K system's); the product page prints "Cooling/Heating Capacity: 12,000 BTU/h". Location: Manual section 1, RATED HEATING, 12K SYSTEM Official user manual · EG4 9K & 12K Mini-Split R32 user manual, version 1.0.1 (outdoor DWA4-09KR2 and DWA4-12KR2, indoor DGA3-09KR2 and DGA3-12KR2)Official document · EG4 9K & 12K AC Mini-Split R32 spec sheet, version 1.0.1 [1, 2] |
| HSPF2 | 9.7Documented claim ConditionsPrinted as "HSPF2-4 10.5 9.7" (the manual's table prints the 9K and 12K systems side by side; the second figure is the 12K system's); HSPF2 for climate region 4. Manufacturer claim. Location: Manual section 1, RATED HEATING, 12K SYSTEM Printed as "HSPF2-4 10.5 9.7" (the manual's table prints the 9K and 12K systems side by side; the second figure is the 12K system's); HSPF2 for climate region 4. Manufacturer claim. Location: Manual section 1, RATED HEATING, 12K SYSTEM Official user manual · EG4 9K & 12K Mini-Split R32 user manual, version 1.0.1 (outdoor DWA4-09KR2 and DWA4-12KR2, indoor DGA3-09KR2 and DGA3-12KR2)Official document · EG4 9K & 12K AC Mini-Split R32 spec sheet, version 1.0.1 [1, 2] |
| Indoor unit model | DGA3-12KR2Documented claim ConditionsPrinted on the cover as "INDOOR MODEL #: DGA3-09KR2 AND DGA3-12KR2" and as the indoor unit table's column heads. Location: Manual cover and section 1, INDOOR UNIT DATA Printed on the cover as "INDOOR MODEL #: DGA3-09KR2 AND DGA3-12KR2" and as the indoor unit table's column heads. Location: Manual cover and section 1, INDOOR UNIT DATA Official user manual · EG4 9K & 12K Mini-Split R32 user manual, version 1.0.1 (outdoor DWA4-09KR2 and DWA4-12KR2, indoor DGA3-09KR2 and DGA3-12KR2)Official document · EG4 9K & 12K AC Mini-Split R32 spec sheet, version 1.0.1 [1, 2] |
| Outdoor noise | 52 dBDocumented claim ConditionsPrinted as "SOUND PRESSURE (HI/MED/LO) 52 dB(A)" for both outdoor units; EG4 prints no measuring distance. Location: Manual section 1, OUTDOOR UNIT DATA Printed as "SOUND PRESSURE (HI/MED/LO) 52 dB(A)" for both outdoor units; EG4 prints no measuring distance. Location: Manual section 1, OUTDOOR UNIT DATA Official user manual · EG4 9K & 12K Mini-Split R32 user manual, version 1.0.1 (outdoor DWA4-09KR2 and DWA4-12KR2, indoor DGA3-09KR2 and DGA3-12KR2)Official document · EG4 9K & 12K AC Mini-Split R32 spec sheet, version 1.0.1Official product page · EG4 Electronics product page: EG4 12K BTU Mini-Split Air Conditioner / Heat Pump R32 (SKU EG4MSAC12V1) [1, 2, 3] |
| Outdoor unit model | DWA4-12KR2Documented claim ConditionsPrinted on the cover as "OUDOOR MODEL #: DWA4-09KR2 AND DWA4-12KR2" (EG4's spelling) and as the outdoor unit table's column heads. Location: Manual cover and section 1, OUTDOOR UNIT DATA Printed on the cover as "OUDOOR MODEL #: DWA4-09KR2 AND DWA4-12KR2" (EG4's spelling) and as the outdoor unit table's column heads. Location: Manual cover and section 1, OUTDOOR UNIT DATA Official user manual · EG4 9K & 12K Mini-Split R32 user manual, version 1.0.1 (outdoor DWA4-09KR2 and DWA4-12KR2, indoor DGA3-09KR2 and DGA3-12KR2)Official document · EG4 9K & 12K AC Mini-Split R32 spec sheet, version 1.0.1 [1, 2] |
| Refrigerant | R32Documented claim ConditionsPrinted as "REFRIGERANT R32/21.2 oz. (0.63 L) R32/27.5 oz. (0.81 L)"; the 12K system's charge is R32/27.5 oz. (0.81 L). Location: Manual section 1, SYSTEM DATA Printed as "REFRIGERANT R32/21.2 oz. (0.63 L) R32/27.5 oz. (0.81 L)"; the 12K system's charge is R32/27.5 oz. (0.81 L). Location: Manual section 1, SYSTEM DATA Official user manual · EG4 9K & 12K Mini-Split R32 user manual, version 1.0.1 (outdoor DWA4-09KR2 and DWA4-12KR2, indoor DGA3-09KR2 and DGA3-12KR2)Official document · EG4 9K & 12K AC Mini-Split R32 spec sheet, version 1.0.1 [1, 2] |
| SEER2 | 22.5Documented claim ConditionsPrinted as "SEER2 25 22.5" (the manual's table prints the 9K and 12K systems side by side; the second figure is the 12K system's). Manufacturer claim. Location: Manual section 1, RATED COOLING, 12K SYSTEM Printed as "SEER2 25 22.5" (the manual's table prints the 9K and 12K systems side by side; the second figure is the 12K system's). Manufacturer claim. Location: Manual section 1, RATED COOLING, 12K SYSTEM Official user manual · EG4 9K & 12K Mini-Split R32 user manual, version 1.0.1 (outdoor DWA4-09KR2 and DWA4-12KR2, indoor DGA3-09KR2 and DGA3-12KR2)Official document · EG4 9K & 12K AC Mini-Split R32 spec sheet, version 1.0.1 [1, 2] |
| Voltage | 115 VDocumented claim ConditionsPrinted as "RATED VOLTAGE 115 VAC" for both systems, with "FREQUENCY 60 Hz". Location: Manual section 1, ELECTRICAL Printed as "RATED VOLTAGE 115 VAC" for both systems, with "FREQUENCY 60 Hz". Location: Manual section 1, ELECTRICAL Official user manual · EG4 9K & 12K Mini-Split R32 user manual, version 1.0.1 (outdoor DWA4-09KR2 and DWA4-12KR2, indoor DGA3-09KR2 and DGA3-12KR2)Official document · EG4 9K & 12K AC Mini-Split R32 spec sheet, version 1.0.1 [1, 2] |
| Weight | 28.5 kg62.8 lb convertedDocumented claim ConditionsThe outdoor unit's (DWA4-12KR2) net weight, printed as "62.9/73.9 lbs. (28.5/33.5 kg)" (net/gross), one value for both the 9K and 12K outdoor units. The indoor unit (DGA3-12KR2) is printed separately under INDOOR UNIT DATA (page 2, PDF page 4) as "UNIT/PACKAGED WEIGHT 20.9/26.0 lbs. (9.5/11.8 kg)". The spec sheet prints the same figures. Location: Manual section 1, OUTDOOR UNIT DATA, NET/GROSS WEIGHT (page 1, PDF page 3) The outdoor unit's (DWA4-12KR2) net weight, printed as "62.9/73.9 lbs. (28.5/33.5 kg)" (net/gross), one value for both the 9K and 12K outdoor units. The indoor unit (DGA3-12KR2) is printed separately under INDOOR UNIT DATA (page 2, PDF page 4) as "UNIT/PACKAGED WEIGHT 20.9/26.0 lbs. (9.5/11.8 kg)". The spec sheet prints the same figures. Location: Manual section 1, OUTDOOR UNIT DATA, NET/GROSS WEIGHT (page 1, PDF page 3) Official user manual · EG4 9K & 12K Mini-Split R32 user manual, version 1.0.1 (outdoor DWA4-09KR2 and DWA4-12KR2, indoor DGA3-09KR2 and DGA3-12KR2)Official document · EG4 9K & 12K AC Mini-Split R32 spec sheet, version 1.0.1 [1, 2] |
Warranty
| Warranty term | 5 yearsDocumented claim ConditionsPrinted as "LIMITED WARRANTY* 5-year limited warranty"; coverage terms are set by EG4's warranty policy, which was not captured. Location: Manual section 1, WARRANTY Printed as "LIMITED WARRANTY* 5-year limited warranty"; coverage terms are set by EG4's warranty policy, which was not captured. Location: Manual section 1, WARRANTY Official user manual · EG4 9K & 12K Mini-Split R32 user manual, version 1.0.1 (outdoor DWA4-09KR2 and DWA4-12KR2, indoor DGA3-09KR2 and DGA3-12KR2)Official document · EG4 9K & 12K AC Mini-Split R32 spec sheet, version 1.0.1 [1, 2] |
|---|
Certificate records
No records documented.
Sources and revisions
- EG4 9K & 12K Mini-Split R32 user manual, version 1.0.1 (outdoor DWA4-09KR2 and DWA4-12KR2, indoor DGA3-09KR2 and DGA3-12KR2)Official user manual · Checked https://eg4electronics.com/wp-content/uploads/2025/10/EG4-9k-12k-BTU-Mini-Split-Air-Conditioner-Heat-Pump-R32-User-Manual.pdf
- EG4 9K & 12K AC Mini-Split R32 spec sheet, version 1.0.1Official document · Checked https://eg4electronics.com/wp-content/uploads/2025/10/EG4-9k-12k-BTU-Mini-Split-Air-Conditioner-Heat-Pump-R32-Spec-Sheet.pdf
- EG4 Electronics product page: EG4 12K BTU Mini-Split Air Conditioner / Heat Pump R32 (SKU EG4MSAC12V1)Official product page · Checked https://eg4electronics.com/categories/high-efficiency-appliances/eg4-12k-btu-mini-split-air-conditioner-heat-pump-r32/