Charged Reviews

Quick reference

EG4 36K Multizone Mini-Split AC/DC Outdoor Unit (DW4E1-ACDC-36KR2(US))

Model: DW4E1-ACDC-36KR2(US) · SKU: EG4MSMZHYB36ODV1

Prepared Nov 12, 2026

Common specifications

Cooling capacity
36,000 BTU/hSource [1]
Heating capacity
36,000 BTU/hSource [1]
SEER2
22.5Source [1]
EER2Not documented
HSPF2
10Source [1]
Refrigerant
R32Source [1]
Refrigerant GWPNot documented
Voltage
208 to 240 VSource [1]
Solar input voltageNot documented
Maximum solar inputNot documented
AHRI certificate numberNot documented
Indoor noiseNot documented
Outdoor noise
60 dBSource [1]
Indoor unit modelNot documented
Outdoor unit modelNot documented
Operating temperatureNot documented
Rated current (as printed)Not documented
Power inputNot documented
DimensionsNot documented
Weight
78.02 kg172 lb convertedCalculatedSource [1]
CommunicationsNot documented
Certifications (as printed)Not documented
Enclosure volumeNot documented
Warranty term
5 yearsSource [1]

All recorded specifications

Cooling capacity
36,000 BTU/hDocumented claim
Conditions

Printed as "Cooling Capacity 36,000 BTU/h" in the spec sheet's cooling table; EG4 prints no rating conditions there. Manufacturer claim, not an independent test.

Location: Spec sheet page 4, Cooling Performance Specifications

Printed as "Cooling Capacity 36,000 BTU/h" in the spec sheet's cooling table; EG4 prints no rating conditions there. Manufacturer claim, not an independent test.

Location: Spec sheet page 4, Cooling Performance Specifications

[1]
Heating capacity
36,000 BTU/hDocumented claim
Conditions

Printed as "Heating Capacity 36,000 BTU/h" in the spec sheet's heating table. Manufacturer claim, not an independent test.

Location: Spec sheet page 4, Heating Performance Specifications

Printed as "Heating Capacity 36,000 BTU/h" in the spec sheet's heating table. Manufacturer claim, not an independent test.

Location: Spec sheet page 4, Heating Performance Specifications

[1]
HSPF2
10Documented claim
Conditions

Printed as "HSPF2 10" in the spec sheet's heating table. Manufacturer claim.

Location: Spec sheet page 4, Heating Performance Specifications

Printed as "HSPF2 10" in the spec sheet's heating table. Manufacturer claim.

Location: Spec sheet page 4, Heating Performance Specifications

[1]
Outdoor noise
60 dBDocumented claim
Conditions

Printed as "Operating Noise 60 dB" for the outdoor unit; EG4 prints no measuring distance.

Location: Spec sheet page 7, Outdoor Unit Mechanical and Environmental Specifications

Printed as "Operating Noise 60 dB" for the outdoor unit; EG4 prints no measuring distance.

Location: Spec sheet page 7, Outdoor Unit Mechanical and Environmental Specifications

[1]
Refrigerant
R32Documented claim
Conditions

Printed as "System Refrigerant R32" in the spec sheet's system details.

Location: Spec sheet page 7, System Details

Printed as "System Refrigerant R32" in the spec sheet's system details.

Location: Spec sheet page 7, System Details

[1]
SEER2
22.5Documented claim
Conditions

Printed as "SEER2 22.5" in the spec sheet's cooling table. Manufacturer claim.

Location: Spec sheet page 4, Cooling Performance Specifications

Printed as "SEER2 22.5" in the spec sheet's cooling table. Manufacturer claim.

Location: Spec sheet page 4, Cooling Performance Specifications

[1]
Voltage
208 to 240 VDocumented claim
Conditions

Printed as "AC Input Voltage 208 – 240 VAC" and "Frequency 60Hz" in the spec sheet's power source table; AC breaker size 32 A as printed.

Location: Spec sheet page 5, Power Source Specifications

Printed as "AC Input Voltage 208 – 240 VAC" and "Frequency 60Hz" in the spec sheet's power source table; AC breaker size 32 A as printed.

Location: Spec sheet page 5, Power Source Specifications

[1]
Weight
78.02 kg172 lb convertedCalculated172 lb x 0.45359237 kg/lb, rounded to 0.01 kg
Conditions

Printed as "Product Weight 172 lbs." for the outdoor unit; converted from pounds.

Location: Spec sheet page 7, Outdoor Unit Mechanical and Environmental Specifications

Printed as "Product Weight 172 lbs." for the outdoor unit; converted from pounds.

Location: Spec sheet page 7, Outdoor Unit Mechanical and Environmental Specifications

[1]

Warranty

Warranty term
5 yearsDocumented claim
Conditions

Printed as "Warranty 5 year limited" in the spec sheet; coverage terms are set by EG4's warranty policy, which was not captured.

Location: Spec sheet page 7, System Details

Printed as "Warranty 5 year limited" in the spec sheet; coverage terms are set by EG4's warranty policy, which was not captured.

Location: Spec sheet page 7, System Details

[1]

Certificate records

No records documented.

Sources and revisions

  1. EG4 36K BTU Hybrid Multizone Mini-Split technical specification sheet, model DW4E1-ACDC-36KR2(US), version 1.0.1Official datasheet · Checked https://eg4electronics.com/wp-content/uploads/2026/04/EG4-36K-Multizone-Mini-Split-ACDC-Spec-Sheet.pdf
  2. EG4 Electronics product page for the EG4 36K Multizone Mini-Split AC/DC (eg4electronics.com, October 27, 2026 capture)Official product page · Checked https://eg4electronics.com/categories/high-efficiency-appliances/eg4-36k-multizone-mini-split-ac-dc/