Charged Reviews
Quick reference
EG4 36K Multizone Mini-Split AC/DC Outdoor Unit (DW4E1-ACDC-36KR2(US))
Model: DW4E1-ACDC-36KR2(US) · SKU: EG4MSMZHYB36ODV1
Prepared Nov 12, 2026

Common specifications
| Cooling capacity | 36,000 BTU/hSource [1] |
|---|---|
| Heating capacity | 36,000 BTU/hSource [1] |
| SEER2 | 22.5Source [1] |
| EER2 | Not documented |
| HSPF2 | 10Source [1] |
| Refrigerant | R32Source [1] |
| Refrigerant GWP | Not documented |
| Voltage | 208 to 240 VSource [1] |
| Solar input voltage | Not documented |
| Maximum solar input | Not documented |
| AHRI certificate number | Not documented |
| Indoor noise | Not documented |
| Outdoor noise | 60 dBSource [1] |
| Indoor unit model | Not documented |
| Outdoor unit model | Not documented |
| Operating temperature | Not documented |
| Rated current (as printed) | Not documented |
| Power input | Not documented |
| Dimensions | Not documented |
| Weight | |
| Communications | Not documented |
| Certifications (as printed) | Not documented |
| Enclosure volume | Not documented |
| Warranty term | 5 yearsSource [1] |
All recorded specifications
| Cooling capacity | 36,000 BTU/hDocumented claim ConditionsPrinted as "Cooling Capacity 36,000 BTU/h" in the spec sheet's cooling table; EG4 prints no rating conditions there. Manufacturer claim, not an independent test. Location: Spec sheet page 4, Cooling Performance Specifications Printed as "Cooling Capacity 36,000 BTU/h" in the spec sheet's cooling table; EG4 prints no rating conditions there. Manufacturer claim, not an independent test. Location: Spec sheet page 4, Cooling Performance Specifications |
|---|---|
| Heating capacity | 36,000 BTU/hDocumented claim ConditionsPrinted as "Heating Capacity 36,000 BTU/h" in the spec sheet's heating table. Manufacturer claim, not an independent test. Location: Spec sheet page 4, Heating Performance Specifications Printed as "Heating Capacity 36,000 BTU/h" in the spec sheet's heating table. Manufacturer claim, not an independent test. Location: Spec sheet page 4, Heating Performance Specifications |
| HSPF2 | 10Documented claim ConditionsPrinted as "HSPF2 10" in the spec sheet's heating table. Manufacturer claim. Location: Spec sheet page 4, Heating Performance Specifications Printed as "HSPF2 10" in the spec sheet's heating table. Manufacturer claim. Location: Spec sheet page 4, Heating Performance Specifications |
| Outdoor noise | 60 dBDocumented claim ConditionsPrinted as "Operating Noise 60 dB" for the outdoor unit; EG4 prints no measuring distance. Location: Spec sheet page 7, Outdoor Unit Mechanical and Environmental Specifications Printed as "Operating Noise 60 dB" for the outdoor unit; EG4 prints no measuring distance. Location: Spec sheet page 7, Outdoor Unit Mechanical and Environmental Specifications |
| Refrigerant | R32Documented claim ConditionsPrinted as "System Refrigerant R32" in the spec sheet's system details. Location: Spec sheet page 7, System Details Printed as "System Refrigerant R32" in the spec sheet's system details. Location: Spec sheet page 7, System Details |
| SEER2 | 22.5Documented claim ConditionsPrinted as "SEER2 22.5" in the spec sheet's cooling table. Manufacturer claim. Location: Spec sheet page 4, Cooling Performance Specifications Printed as "SEER2 22.5" in the spec sheet's cooling table. Manufacturer claim. Location: Spec sheet page 4, Cooling Performance Specifications |
| Voltage | 208 to 240 VDocumented claim ConditionsPrinted as "AC Input Voltage 208 – 240 VAC" and "Frequency 60Hz" in the spec sheet's power source table; AC breaker size 32 A as printed. Location: Spec sheet page 5, Power Source Specifications Printed as "AC Input Voltage 208 – 240 VAC" and "Frequency 60Hz" in the spec sheet's power source table; AC breaker size 32 A as printed. Location: Spec sheet page 5, Power Source Specifications |
| Weight | 78.02 kg172 lb convertedCalculated172 lb x 0.45359237 kg/lb, rounded to 0.01 kg ConditionsPrinted as "Product Weight 172 lbs." for the outdoor unit; converted from pounds. Location: Spec sheet page 7, Outdoor Unit Mechanical and Environmental Specifications Printed as "Product Weight 172 lbs." for the outdoor unit; converted from pounds. Location: Spec sheet page 7, Outdoor Unit Mechanical and Environmental Specifications |
Warranty
| Warranty term | 5 yearsDocumented claim ConditionsPrinted as "Warranty 5 year limited" in the spec sheet; coverage terms are set by EG4's warranty policy, which was not captured. Location: Spec sheet page 7, System Details Printed as "Warranty 5 year limited" in the spec sheet; coverage terms are set by EG4's warranty policy, which was not captured. Location: Spec sheet page 7, System Details |
|---|
Certificate records
No records documented.
Sources and revisions
- EG4 36K BTU Hybrid Multizone Mini-Split technical specification sheet, model DW4E1-ACDC-36KR2(US), version 1.0.1Official datasheet · Checked https://eg4electronics.com/wp-content/uploads/2026/04/EG4-36K-Multizone-Mini-Split-ACDC-Spec-Sheet.pdf
- EG4 Electronics product page for the EG4 36K Multizone Mini-Split AC/DC (eg4electronics.com, October 27, 2026 capture)Official product page · Checked https://eg4electronics.com/categories/high-efficiency-appliances/eg4-36k-multizone-mini-split-ac-dc/