Charged Reviews

Quick reference

EG4 24K Hybrid Solar Mini-Split AC/DC, R410A (DGWA2-ACDC1-24K)

Model: DGWA2-ACDC1-24K · SKU: DGWA2-ACDC1-24K

Prepared Nov 12, 2026

Common specifications

Cooling capacity
22,000 BTU/hSource [1, 2, 3]
Heating capacity
27,000 BTU/hSource [1, 2]
SEER2
21Source [1, 2, 3]
EER2Not documented
HSPF2
11Source [1, 2, 3]
Refrigerant
R410ASource [1, 2]
Refrigerant GWPNot documented
Voltage
208 to 240 VSource [1]
Solar input voltage
90 to 380 VSource [1, 3]
Maximum solar input
2,200 WSource [1, 2]
AHRI certificate numberNot documented
Indoor noiseNot documented
Outdoor noise
58 dBSource [1, 3]
Indoor unit modelNot documented
Outdoor unit modelNot documented
Operating temperatureNot documented
Rated current (as printed)Not documented
Power inputNot documented
DimensionsNot documented
WeightNot documented
CommunicationsNot documented
Certifications (as printed)Not documented
Enclosure volumeNot documented
Warranty term
5 yearsSource [1]

All recorded specifications

Cooling capacity
22,000 BTU/hDocumented claim
Conditions

Printed as "NOMINAL CAPACITY 11,000 BTU/h 22,000 BTU/h" under RATED COOLING in the user manual (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's; operating range "6,000 – 27,000 BTU/h"). The spec sheet (version 2.2) prints "NOMINAL CAPACITY 12,000 BTU/h 24,000 BTU/h" (range "6,100 – 25,200 BTU/h"), and the product page "Capacities: 6,100-25,200 BTU/h"; the manual, the primary source, is recorded and the difference is left unresolved. Manufacturer claim.

Location: Manual section 1, RATED COOLING, 24K SYSTEM

Printed as "NOMINAL CAPACITY 11,000 BTU/h 22,000 BTU/h" under RATED COOLING in the user manual (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's; operating range "6,000 – 27,000 BTU/h"). The spec sheet (version 2.2) prints "NOMINAL CAPACITY 12,000 BTU/h 24,000 BTU/h" (range "6,100 – 25,200 BTU/h"), and the product page "Capacities: 6,100-25,200 BTU/h"; the manual, the primary source, is recorded and the difference is left unresolved. Manufacturer claim.

Location: Manual section 1, RATED COOLING, 24K SYSTEM

[1, 2, 3]
Heating capacity
27,000 BTU/hDocumented claim
Conditions

Printed as "NOMINAL CAPACITY 13,500 BTU/h 27,000 BTU/h" under RATED HEATING in the user manual (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's). The spec sheet prints "NOMINAL CAPACITY 12,500 BTU/h 26,000 BTU/h"; the manual is recorded and the difference is left unresolved. Manufacturer claim.

Location: Manual section 1, RATED HEATING, 24K SYSTEM

Printed as "NOMINAL CAPACITY 13,500 BTU/h 27,000 BTU/h" under RATED HEATING in the user manual (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's). The spec sheet prints "NOMINAL CAPACITY 12,500 BTU/h 26,000 BTU/h"; the manual is recorded and the difference is left unresolved. Manufacturer claim.

Location: Manual section 1, RATED HEATING, 24K SYSTEM

[1, 2]
HSPF2
11Documented claim
Conditions

Printed as "HSPF2-4 (W/W) 10.8 11" in the user manual (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's); HSPF2 for climate region 4. The manual also prints "HSPF2-5 (W/W) 8.4 9" (region 5), and the spec sheet prints "HSPF2 10.5 9.6" with no region, as does the product page ("HSPF2: 9.6"); the manual's region 4 figure is recorded and the difference is left unresolved. Manufacturer claim.

Location: Manual section 1, RATED HEATING, 24K SYSTEM

Printed as "HSPF2-4 (W/W) 10.8 11" in the user manual (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's); HSPF2 for climate region 4. The manual also prints "HSPF2-5 (W/W) 8.4 9" (region 5), and the spec sheet prints "HSPF2 10.5 9.6" with no region, as does the product page ("HSPF2: 9.6"); the manual's region 4 figure is recorded and the difference is left unresolved. Manufacturer claim.

Location: Manual section 1, RATED HEATING, 24K SYSTEM

[1, 2, 3]
Maximum solar input
2,200 WDocumented claim
Conditions

Printed as "RATED PV WATTAGE 1100 2200" in the user manual (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's; no unit printed there); the spec sheet prints "RATED PV WATTAGE 1100W 2200W". The product page's "Recommended Solar Input: 1600-2400W" is a recommendation and is not recorded.

Location: Manual section 1, ELECTRICAL (DC), 24K SYSTEM

Printed as "RATED PV WATTAGE 1100 2200" in the user manual (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's; no unit printed there); the spec sheet prints "RATED PV WATTAGE 1100W 2200W". The product page's "Recommended Solar Input: 1600-2400W" is a recommendation and is not recorded.

Location: Manual section 1, ELECTRICAL (DC), 24K SYSTEM

[1, 2]
Outdoor noise
58 dBDocumented claim
Conditions

Printed as "SOUND PRESSURE (HI/MED/LO) 52 dB(A) 58 dB(A)" for the outdoor units (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's); EG4 prints no measuring distance. The product page prints "Outdoor Unit Sound: (Hi/Med/Lo) 58 dB(A)".

Location: Manual section 1, OUTDOOR UNIT DATA, 24K SYSTEM

Printed as "SOUND PRESSURE (HI/MED/LO) 52 dB(A) 58 dB(A)" for the outdoor units (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's); EG4 prints no measuring distance. The product page prints "Outdoor Unit Sound: (Hi/Med/Lo) 58 dB(A)".

Location: Manual section 1, OUTDOOR UNIT DATA, 24K SYSTEM

[1, 3]
Refrigerant
R410ADocumented claim
Conditions

Printed as "REFRIGERANT R410A/38.8 oz. (1.14L) R410A/56.43 oz. (1.66L)" (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's); the 24K system's charge is 56.43 oz. (1.66 L) in the manual and "R410A/56.43 oz. (1.67L)" in the spec sheet.

Location: Manual section 1, SYSTEM DATA, 24K SYSTEM

Printed as "REFRIGERANT R410A/38.8 oz. (1.14L) R410A/56.43 oz. (1.66L)" (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's); the 24K system's charge is 56.43 oz. (1.66 L) in the manual and "R410A/56.43 oz. (1.67L)" in the spec sheet.

Location: Manual section 1, SYSTEM DATA, 24K SYSTEM

[1, 2]
SEER2
21Documented claim
Conditions

Printed as "SEER2 (W/W) 21.5 21" in the user manual (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's); the spec sheet prints "SEER2 22 BTU/W 21 BTU/W" and the product page "SEER2 Rating: 21". Manufacturer claim.

Location: Manual section 1, RATED COOLING, 24K SYSTEM

Printed as "SEER2 (W/W) 21.5 21" in the user manual (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's); the spec sheet prints "SEER2 22 BTU/W 21 BTU/W" and the product page "SEER2 Rating: 21". Manufacturer claim.

Location: Manual section 1, RATED COOLING, 24K SYSTEM

[1, 2, 3]
Solar input voltage
90 to 380 VDocumented claim
Conditions

Printed as "RATED VOLTAGE 90VDC – 380VDC" under ELECTRICAL (DC), one figure for both systems, with "MAXIMUM PV VOLTAGE 380 VOC" and "MAXIMUM PV AMPERAGE (ISC) 12A". The product page prints "Recommended Solar Input: 1600-2400W (90VDC-380VDC)".

Location: Manual section 1, ELECTRICAL (DC)

Printed as "RATED VOLTAGE 90VDC – 380VDC" under ELECTRICAL (DC), one figure for both systems, with "MAXIMUM PV VOLTAGE 380 VOC" and "MAXIMUM PV AMPERAGE (ISC) 12A". The product page prints "Recommended Solar Input: 1600-2400W (90VDC-380VDC)".

Location: Manual section 1, ELECTRICAL (DC)

[1, 3]
Voltage
208 to 240 VDocumented claim
Conditions

Printed as "RATED VOLTAGE 115VAC 208VAC – 240VAC" under ELECTRICAL (AC) (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's), with "FREQUENCY 60Hz".

Location: Manual section 1, ELECTRICAL (AC), 24K SYSTEM

Printed as "RATED VOLTAGE 115VAC 208VAC – 240VAC" under ELECTRICAL (AC) (the manual's table prints the 12K and 24K systems side by side; the second figure is the 24K system's), with "FREQUENCY 60Hz".

Location: Manual section 1, ELECTRICAL (AC), 24K SYSTEM

[1]

Warranty

Warranty term
5 yearsDocumented claim
Conditions

Printed as "LIMITED WARRANTY 5-Year limited warranty"; coverage terms are set by EG4's warranty policy, which was not captured.

Location: Manual section 1, WARRANTY

Printed as "LIMITED WARRANTY 5-Year limited warranty"; coverage terms are set by EG4's warranty policy, which was not captured.

Location: Manual section 1, WARRANTY

[1]

Certificate records

No records documented.

Sources and revisions

  1. EG4 12K & 24K Hybrid Solar Mini-Split user manual, version 2.3.1 (MODEL #: DGWA3-ACDC1-12K & DGWA2-ACDC1-24K)Official user manual · Checked https://eg4electronics.com/wp-content/uploads/2024/04/EG4-AC-DC-Plug-N-Cool-Solar-AC-Manual-12K-24K.pdf
  2. EG4 Hybrid AC/DC Mini-Split spec sheet (12K and 24K systems), version 2.2Official document · Checked https://eg4electronics.com/wp-content/uploads/2024/04/EG4-24K-BTU-AC-DC-Plug-N-Cool-Solar-AC-Spec-Sheet.pdf
  3. EG4 Electronics product page: 24K Hybrid Solar Mini-Split 24000BTU AC/DC Air Conditioner/ Heat Pump (SKU EG4HYB24BTUID & EG4HYB24BTUOD)Official product page · Checked https://eg4electronics.com/categories/high-efficiency-appliances/eg4-24k-hybrid-solar-unit/