SolarEdge BI-NUSGN-02 Home Backup Interface
No sellers found.
Key specs
Units- Transfer time
- 100 msSource document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. The row prints a strict upper bound, <100 ms. The stored scalar is the bound, not an exact observed switchover time.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 2, Input from Grid / Grid Disconnection Switchover Time
Documented
- Weight
- 33 kg73 lb convertedSource document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. The value is read from this exact model column or its shared specification row.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 3, Weight
Documented
- Dimensions
- 40.41 LW: 352.5 × H: 523.5 × D: 219 mmW: 13.88 × H: 20.61 × D: 8.62 in convertedSource document
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. The printed dimensions are H x W x D: 523.5 x 352.5 x 219 mm.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 3, Dimensions (H×W×D)
Calculated
- Enclosure
- NEMA 3R, IP44Source document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. The value is read from this exact model column or its shared specification row.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 3, Protection Rating
Documented
- Safety listing
- UL1741, CSA 22.2 NO. 107; FCC part 15 class BSource document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. Maker compliance claims only, not an issuer listing or certificate check. UL 869A appears only in the EUSGN column; the NUSGN column prints N/A.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 3, Standard Compliance / Safety and Emissions
Documented
- Service voltage
- 240 Vac nominal L-L (211 to 264 Vac), 60 Hz (59.3 to 60.5 Hz); 120 V L-N in backup (105 to 132 V, 55 to 65 Hz)Source document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. Grid line-to-line voltage is nominal 240 Vac (211 to 264 Vac), 60 Hz (59.3 to 60.5 Hz). Backup line-to-neutral voltage is nominal 120 V (105 to 132 V), with a separate 55 to 65 Hz frequency range.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 2, Input from Grid and Output to Main Distribution Panel
Documented
- PV and storage ports
- Up to 3 inverter inputs; maximum rated AC power in on-grid and backup operation 11400 W; maximum continuous current 48 A; factory installed inverter input AC circuit breaker 40 A, upgradable up to 3 x 63 A circuit breakersSource document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. The 48 A and 11400 W ratings are inverter-input rows. Footnote 1 says each 40 A breaker supports one 7.6 kW inverter; each 63 A breaker supports one 10 kW and one 11.4 kW inverter. These statements do not establish an installed configuration.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 2, Input from Inverter
Documented
- Maximum current
- 200 ASource document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. The 200 A rating is the grid/MID or main-panel output rating, separate from inverter and generator inputs.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 2, Input from Grid / AC Current Input; MID Rated Current
Documented
2 specs not documented yet: rated capacity, usable capacityHelp fill in ›
All specs12
- Rated capacity
- Not documented
- Usable capacity
- Not documented
- Transfer time
- 100 msSource document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. The row prints a strict upper bound, <100 ms. The stored scalar is the bound, not an exact observed switchover time.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 2, Input from Grid / Grid Disconnection Switchover Time
Documented
Lifetime production
Published claims and calculations are not independently tested lifetime output.
- Weight
- 33 kg73 lb convertedSource document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. The value is read from this exact model column or its shared specification row.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 3, Weight
Documented
- Dimensions
- 40.41 LW: 352.5 × H: 523.5 × D: 219 mmW: 13.88 × H: 20.61 × D: 8.62 in convertedSource document
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. The printed dimensions are H x W x D: 523.5 x 352.5 x 219 mm.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 3, Dimensions (H×W×D)
Calculated
- Enclosure
- NEMA 3R, IP44Source document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. The value is read from this exact model column or its shared specification row.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 3, Protection Rating
Documented
- Safety listing
- UL1741, CSA 22.2 NO. 107; FCC part 15 class BSource document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. Maker compliance claims only, not an issuer listing or certificate check. UL 869A appears only in the EUSGN column; the NUSGN column prints N/A.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 3, Standard Compliance / Safety and Emissions
Documented
- Service voltage
- 240 Vac nominal L-L (211 to 264 Vac), 60 Hz (59.3 to 60.5 Hz); 120 V L-N in backup (105 to 132 V, 55 to 65 Hz)Source document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. Grid line-to-line voltage is nominal 240 Vac (211 to 264 Vac), 60 Hz (59.3 to 60.5 Hz). Backup line-to-neutral voltage is nominal 120 V (105 to 132 V), with a separate 55 to 65 Hz frequency range.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 2, Input from Grid and Output to Main Distribution Panel
Documented
- PV and storage ports
- Up to 3 inverter inputs; maximum rated AC power in on-grid and backup operation 11400 W; maximum continuous current 48 A; factory installed inverter input AC circuit breaker 40 A, upgradable up to 3 x 63 A circuit breakersSource document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. The 48 A and 11400 W ratings are inverter-input rows. Footnote 1 says each 40 A breaker supports one 7.6 kW inverter; each 63 A breaker supports one 10 kW and one 11.4 kW inverter. These statements do not establish an installed configuration.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 2, Input from Inverter
Documented
- Maximum current
- 200 ASource document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. The 200 A rating is the grid/MID or main-panel output rating, separate from inverter and generator inputs.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 2, Input from Grid / AC Current Input; MID Rated Current
Documented
- Generator input
- Maximum rated AC power 15000 W; maximum continuous input current 63 Adc (as printed); dry contact switch rated 250 / 30 Vac / Vdc, 5 A; 2-wire start switchSource document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. The Generator table prints 15000 W and 63 Adc. The Adc unit is retained exactly as printed. Footnote 2 requires supporting inverter firmware; current firmware availability and support were not checked.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 2, Generator
Documented
- Operating temperature
- -40 to 50 °C-40 to 122 °F convertedSource document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. The value is read from this exact model column or its shared specification row.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 3, Operating Temperature Range
Documented
Published claims and calculations, not independent test results.
Documents
- PDFOpenSolarEdge DS-000103-NA, April 3, 2022
Our copy is kept as private evidence and is not available to download. SHA-256: 2c7774d3d49a4689977ce9e033eb30bbf7a5e63413435866dd1345bdfe8fc8f7, captured .
Source details
SolarEdge-authored document, third-party hosted by Fortune Energy Wholesale LLC. Printed edition: DS-000103-NA, April 3, 2022. Exact-model native pages reviewed November 9, 2026. No equivalence to a withdrawn document or current production edition is claimed.
Location: Exact-model native pages; individual fact locators on products.
Retrieved
SolarEdge-authored document, third-party hosted by Fortune Energy Wholesale LLC. Printed edition: DS-000103-NA, April 3, 2022. Exact-model native pages reviewed November 9, 2026. No equivalence to a withdrawn document or current production edition is claimed.
Warranty
- Product warranty
- 12 yearsSource document
Sources
Maker datasheet DS-000103-NA, April 3, 2022; exact BI-EUSGN-02 and BI-NUSGN-02 columns, independent Fortune Energy hosted copy. No equivalence to the withdrawn August 2022 edition or current firmware is claimed. The cover prints a 12-year warranty badge. Full warranty terms were not newly read; no remedy or eligibility is inferred.
Source document: SolarEdge DS-000103-NA, April 3, 2022 Rev DS-000103-NA, April 3, 2022 · Checked · Earlier documentLocation: PDF page 1, Cover warranty badge
Documented
Sellers
No sellers found.
Price history
No seller price history.
Owner reviews
No reviews yet
Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.
Evidence score
This category has no Evidence score.
Certificates
No certificates on file. Certificate guide
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- BI-NUSGN-02
US market
No historical observations recorded yet.
Community discussions
No discussions linked yet. Search DIY Solar Forum
Recalls / legal notices
No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice
Something wrong that is not one of the values above?
Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.