SolarEdge BI-EUSGN-01 Backup Interface

By SolarEdgeSKU not documented

No reviews · Write the first

Key specs

Units
Transfer time
100 ms
Distributor datasheet
Sources

Printed as "Grid Disconnection Switchover Time <100 ms" (an upper bound), one cell shared by both models.

Distributor datasheet: SolarEdge StorEdge Backup Interface for North America, BI-EUSGN-01 / BI-NUSGN-01 (01/2020/V01/ENG NA) Rev 01/2020/V01/ENG NA · Checked · Earlier document

Location: SolarEdge's StorEdge Backup Interface data sheet (01/2020/V01/ENG NA), PDF page 2, INPUT FROM GRID, Grid Disconnection Switchover Time, one cell shared by both models

Documented

Weight
33 kg73 lb converted
Distributor datasheet
Sources

Printed as "73 / 33" lb / Kg, one cell shared by both models; the printed kilogram figure is recorded.

Distributor datasheet: SolarEdge StorEdge Backup Interface for North America, BI-EUSGN-01 / BI-NUSGN-01 (01/2020/V01/ENG NA) Rev 01/2020/V01/ENG NA · Checked · Earlier document

Location: SolarEdge's StorEdge Backup Interface data sheet (01/2020/V01/ENG NA), PDF page 3, INSTALLATION SPECIFICATIONS, Weight, one cell shared by both models

Documented

Dimensions
40.41 L
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 352.5 × H: 523.5 × D: 219 mmW: 13.88 × H: 20.61 × D: 8.62 in convertedDistributor datasheet
Sources

Printed as "20.59 x 13.88 x 8.62 / 523.5 x 352.5 x 219" in / mm (H x W x D), one cell shared by both models; the printed millimeter figures are recorded.

Distributor datasheet: SolarEdge StorEdge Backup Interface for North America, BI-EUSGN-01 / BI-NUSGN-01 (01/2020/V01/ENG NA) Rev 01/2020/V01/ENG NA · Checked · Earlier document

Location: SolarEdge's StorEdge Backup Interface data sheet (01/2020/V01/ENG NA), PDF page 3, INSTALLATION SPECIFICATIONS, Dimensions (HxWxD), one cell shared by both models

Calculated

Enclosure
NEMA 3R, IP44
Distributor datasheet
Sources

Printed as "NEMA 3R, IP44", one cell shared by both models.

Distributor datasheet: SolarEdge StorEdge Backup Interface for North America, BI-EUSGN-01 / BI-NUSGN-01 (01/2020/V01/ENG NA) Rev 01/2020/V01/ENG NA · Checked · Earlier document

Location: SolarEdge's StorEdge Backup Interface data sheet (01/2020/V01/ENG NA), PDF page 3, INSTALLATION SPECIFICATIONS, Protection Rating, one cell shared by both models

Documented

Safety listing
UL1741, CSA 22.2 NO. 107, UL869A; FCC part 15 class B
Distributor datasheet
Sources

Printed as "Safety UL1741, CSA 22.2 NO. 107 UL869A N/A" and "Emissions FCC part 15 class B": the safety row prints UL1741 and CSA 22.2 NO. 107 for both models, and UL869A in the BI-E column with N/A in the BI-N column, read on the rendered page 3. Manufacturer claims; no certificate was read.

Distributor datasheet: SolarEdge StorEdge Backup Interface for North America, BI-EUSGN-01 / BI-NUSGN-01 (01/2020/V01/ENG NA) Rev 01/2020/V01/ENG NA · Checked · Earlier document

Location: SolarEdge's StorEdge Backup Interface data sheet (01/2020/V01/ENG NA), PDF page 3, STANDARD COMPLIANCE, BI-EUSGN-01 column (first of 2)

Documented

Service voltage
240 Vac nominal L-L (211 to 264 Vac), 60 Hz (59.3 to 60.5 Hz); 120 V L-N in backup (105 to 132 V, 55 to 65 Hz)
Distributor datasheet
Sources

Printed as AC Output Voltage (Nominal) 240 Vac, range 211 to 264 Vac, AC Frequency (Nominal) 60 Hz, range 59.3 to 60.5 Hz, and in backup AC L-N Output Voltage (Nominal) 120 V, range 105 to 132 V, frequency range 55 to 65 Hz, each one cell shared by both models.

Distributor datasheet: SolarEdge StorEdge Backup Interface for North America, BI-EUSGN-01 / BI-NUSGN-01 (01/2020/V01/ENG NA) Rev 01/2020/V01/ENG NA · Checked · Earlier document

Location: SolarEdge's StorEdge Backup Interface data sheet (01/2020/V01/ENG NA), PDF page 2, INPUT FROM GRID and OUTPUT TO MAIN DISTRIBUTION PANEL, one cell shared by both models

Documented

PV and storage ports
3 inverter inputs; rated AC power 7,600 W (maximum continuous input current 32 A at 240 V); in continuous backup operation 6,100 W (26 A), peak 7,000 W for under 10 seconds (30 A); inverter input AC circuit breaker 40 A, upgradable up to 3 x 40 A circuit breakers
Distributor datasheet
Sources

Printed in the INPUT FROM INVERTER section as Number of Inverter Inputs "3", Rated AC Power "7,600" W, Maximum Continuous Input Current @ 240V "32" A, Rated AC Power in Continuous Backup Operation "6,100" W, Maximum Continuous Input Current in Backup Operation "26" A, Peak AC Power (<10 sec) in Backup Operation "7,000" W, Peak AC Current (<10 sec) in Backup Operation "30" A, Inverter Input AC Circuit Breaker "40" A and Upgradability "Up to 3 X 40A CB(1)", each one cell shared by both models; footnote (1) says each 40 A circuit breaker supports a 7600 W inverter. Supported inverters are printed as "StorEdge single phase inverter, StorEdge single phase inverter with HD-Wave Technology".

Distributor datasheet: SolarEdge StorEdge Backup Interface for North America, BI-EUSGN-01 / BI-NUSGN-01 (01/2020/V01/ENG NA) Rev 01/2020/V01/ENG NA · Checked · Earlier document

Location: SolarEdge's StorEdge Backup Interface data sheet (01/2020/V01/ENG NA), PDF page 2, INPUT FROM INVERTER, one cell shared by both models

Documented

Maximum current
200 A
Distributor datasheet
Sources

Microgrid Interconnection Device Rated Current printed as "200" A, with AC Current Input 200 A and Maximum AC Current Output (to the main distribution panel) 200 A, each one cell shared by both models. This model also prints a Service Side AC Main Circuit Breaker Rated Current of 200 A.

Distributor datasheet: SolarEdge StorEdge Backup Interface for North America, BI-EUSGN-01 / BI-NUSGN-01 (01/2020/V01/ENG NA) Rev 01/2020/V01/ENG NA · Checked · Earlier document

Location: SolarEdge's StorEdge Backup Interface data sheet (01/2020/V01/ENG NA), PDF page 2, INPUT FROM GRID, Microgrid Interconnection Device Rated Current, one cell shared by both models

Documented

2 specs not documented yet: rated capacity, usable capacityHelp fill in ›

All specs12
Rated capacity
Not documented
Usable capacity
Not documented
Transfer time
100 ms
Distributor datasheet
Sources

Printed as "Grid Disconnection Switchover Time <100 ms" (an upper bound), one cell shared by both models.

Distributor datasheet: SolarEdge StorEdge Backup Interface for North America, BI-EUSGN-01 / BI-NUSGN-01 (01/2020/V01/ENG NA) Rev 01/2020/V01/ENG NA · Checked · Earlier document

Location: SolarEdge's StorEdge Backup Interface data sheet (01/2020/V01/ENG NA), PDF page 2, INPUT FROM GRID, Grid Disconnection Switchover Time, one cell shared by both models

Documented

Lifetime production

Not published

Published claims and calculations are not independently tested lifetime output.

Published claims and calculations, not independent test results.

Documents

1 on file
  • PDF
    SolarEdge StorEdge Backup Interface for North America, BI-EUSGN-01 / BI-NUSGN-01 (01/2020/V01/ENG NA)SolarEdgeDistributor datasheet
    Source details
    Revision
    01/2020/V01/ENG NA
    Revision date
    Not stated

    Archived copy of SolarEdge's document, obtained from sunsuppv.com (copy of SolarEdge's document; www.solaredge.com blocks our fetcher), captured 2026-10-13 at 02:04:20 UTC by Alternative Research. The copy read hashes to the SHA-256 Alternative Research recorded for it.

    Retrieved

    SolarEdge's own data sheet titled "Backup Interface for Flexible Backup for North America BI-EUSGN-01 / BI-NUSGN-01", printed "01/2020/V01/ENG NA". Three pages; its tables (PDF pages 2 and 3) have one column per model, BI-EUSGN-01 and BI-NUSGN-01. This copy was obtained from sunsuppv.com (copy of SolarEdge's document; www.solaredge.com blocks our fetcher), captured 2026-10-13 at 02:04:20 UTC by Alternative Research. Read in full; each model's column was checked on the rendered pages. Manufacturer claims, not an independent test.

    Archived copies

    Archived copy of a document published by SolarEdge. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup 01/2020/V01/ENG NA · 0.12 MB

    Archived copy, unaltered, kept as a record of what SolarEdge published. Original address: https://sunsuppv.com/wp-content/uploads/2020/09/BI-NUSGN-01-and-BI-EUSGN-01_Data_Sheet.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    3
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 16629f83ade237192f458fd758a7ef806f1fa21f220ec6d1a89be3f250a3cd13

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

SolarEdge StorEdge Backup Interface for North America, BI-EUSGN-01 / BI-NUSGN-01 (01/2020/V01/ENG NA)

Archived copy of a document published by SolarEdge. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup 01/2020/V01/ENG NA · 0.12 MB

Archived copy, unaltered, kept as a record of what SolarEdge published. Original address: https://sunsuppv.com/wp-content/uploads/2020/09/BI-NUSGN-01-and-BI-EUSGN-01_Data_Sheet.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
3
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 16629f83ade237192f458fd758a7ef806f1fa21f220ec6d1a89be3f250a3cd13

Submit a document

Warranty

No warranty terms on file.

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

This category has no Evidence score.

Certificates

Listing stated, none checked

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
BI-EUSGN-01

US market

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.