Hoymiles HMID-200-USG1 Microgrid Interconnect Device

By HoymilesSKU not documented

No reviews · Write the first

Key specs

Units
Weight
21 kg46 lb converted
Official datasheet
Sources

Printed as "46.3 lb/21 kg".

Official datasheet: Hoymiles HMID-200-USG1 Microgrid Interconnect Device datasheet (Region: North America, REV1.1) (November 2, 2026 capture) Rev REV1.1 · Checked · Earlier document

Location: PDF page 2, Technical Specifications, General, Weight

Documented

Dimensions
68.57 L
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 651 × H: 747 × D: 141 mmW: 25.6 × H: 29.4 × D: 5.55 in convertedOfficial datasheet
Sources

Printed as "25.63 × 29.4 × 5.55 inch (651 × 747 × 141 mm)", width by height by depth.

Official datasheet: Hoymiles HMID-200-USG1 Microgrid Interconnect Device datasheet (Region: North America, REV1.1) (November 2, 2026 capture) Rev REV1.1 · Checked · Earlier document

Location: PDF page 2, Technical Specifications, General, Dimensions (W × H × D)

Calculated

Enclosure
Type 3R
Official datasheet
Sources

Printed as "Protection degree Type 3R".

Official datasheet: Hoymiles HMID-200-USG1 Microgrid Interconnect Device datasheet (Region: North America, REV1.1) (November 2, 2026 capture) Rev REV1.1 · Checked · Earlier document

Location: PDF page 2, Technical Specifications, General, Protection degree

Documented

Safety listing
UL 1741, CSA C22.2 NO.107.1, UL 1741 PCS, UL 67, UL 869A; FCC part 15 class B
Official datasheet
Sources

Printed as "Certifications and Standards Safety regulations UL 1741, CSA C22.2 NO.107.1, UL 1741 PCS, UL 67, UL 869A EMC FCC part 15 class B". Manufacturer claims; no issuer directory was checked.

Official datasheet: Hoymiles HMID-200-USG1 Microgrid Interconnect Device datasheet (Region: North America, REV1.1) (November 2, 2026 capture) Rev REV1.1 · Checked · Earlier document

Location: PDF page 2, Technical Specifications, Certifications and Standards

Documented

Service voltage
120/240 V AC split phase, 60 Hz
Official datasheet
Sources

Printed as "Nominal AC voltage (V) 120/240 (split phase)" and "Nominal grid frequency (Hz) 60".

Official datasheet: Hoymiles HMID-200-USG1 Microgrid Interconnect Device datasheet (Region: North America, REV1.1) (November 2, 2026 capture) Rev REV1.1 · Checked · Earlier document

Location: PDF page 2, Technical Specifications, Connection to Utility Grid and Household Distribution

Documented

Device type
Microgrid interconnect device for whole-home backup with Hoymiles energy storage inverters: transfers between on-grid and backup mode through a 200 A contactor with manual override
Official datasheet
Sources

The datasheet title prints "HMID-200-USG1 Microgrid Interconnect Device"; datasheet and page print "HMID-200-USG1 paired with Hoymiles energy storage inverter provides an elegant whole home backup solution for residents.", "Reliable operation mode transition with 200 A contactor" and "Integrated with contactor manual override".

Official datasheet: Hoymiles HMID-200-USG1 Microgrid Interconnect Device datasheet (Region: North America, REV1.1) (November 2, 2026 capture) Rev REV1.1 · Checked · Earlier documentOfficial product page: Hoymiles HMID-200-USG1 product page, North America (November 2, 2026 capture) Checked · Earlier document

Location: PDF page 1, title, description and features; product page introduction and Features

Documented

PV and storage ports
Solar: 64 A continuous, 80 A maximum overcurrent protection device; storage: 48 A continuous, 60 A maximum overcurrent protection device (three storage branches); smart load: 64 A continuous, 80 A maximum overcurrent protection device; up to three Hoymiles energy storage inverters
Official datasheet
Sources

Printed as "Connection to Inverter Max. continuous current rating for solar (A) 64 Max. overcurrent protection device rating for solar (A) 80 Max. continuous current rating for storage (A) 48 Max. overcurrent protection device rating for storage (A)(2) 60 Connection to Smart Load Max. continuous current rating (A) 64 Max. overcurrent protection device rating (A) 80", with the note "(2) There are three branches for storage connection."; datasheet and page print "Supports whole-home backup; Up to three energy storage inverters can be connected".

Official datasheet: Hoymiles HMID-200-USG1 Microgrid Interconnect Device datasheet (Region: North America, REV1.1) (November 2, 2026 capture) Rev REV1.1 · Checked · Earlier documentOfficial product page: Hoymiles HMID-200-USG1 product page, North America (November 2, 2026 capture) Checked · Earlier document

Location: PDF page 2, Technical Specifications, Connection to Inverter and Connection to Smart Load; features

Documented

Maximum current
160 A
Official datasheet
Sources

Printed as "Max. continuous current rating (A) 160" for the grid and household distribution connection; the same table prints "Max. grid port overcurrent rating (A)(1) 200" and "Max. backup load port overcurrent protection device (A) 200".

Official datasheet: Hoymiles HMID-200-USG1 Microgrid Interconnect Device datasheet (Region: North America, REV1.1) (November 2, 2026 capture) Rev REV1.1 · Checked · Earlier document

Location: PDF page 2, Technical Specifications, Connection to Utility Grid and Household Distribution, Max. continuous current rating (A)

Documented

2 specs not documented yet: rated capacity, usable capacityHelp fill in ›

All specs14
Rated capacity
Not documented
Usable capacity
Not documented

Lifetime production

Not published

Published claims and calculations are not independently tested lifetime output.

Published claims and calculations, not independent test results.

Documents

2 on file
  • PDF
    Hoymiles HMID-200-USG1 Microgrid Interconnect Device datasheet (Region: North America, REV1.1) (November 2, 2026 capture)OfficialHoymilesOfficial datasheet
    Source details
    Revision
    REV1.1
    Revision date
    Not stated

    Reached from Hoymiles' download page https://www.hoymiles.com/downloads/datasheet-hmid-200-usg1-en.html; obtained by Alternative Research, captured 2026-11-02T01:58:16.160Z (archived copy).

    Location: PDF page 1 (description, features); PDF page 2, Technical Specifications

    Retrieved

    Hoymiles' own datasheet for the HMID-200-USG1 microgrid interconnect device (Region: North America, REV1.1), listed on Hoymiles' download page https://www.hoymiles.com/downloads/datasheet-hmid-200-usg1-en.html, which redirects to this file on Hoymiles' file host. Obtained by Alternative Research on November 2, 2026 (captured 01:58:16.160 UTC), because Hoymiles' file host answers our fetcher with a 403; each fact was checked against the printed page. Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup REV1.1 · 0.66 MB

    Archived copy, unaltered, kept as a record of what Hoymiles published. Original address: https://w3oss.hoymiles.com/uploadfile/1/202507/0ebd42d2c9.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    2
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 9893b65ac1f9e999aea6f25f7db28a480a85955bb514459e956efb4f53f40218

    Open
  • WEB
    Hoymiles HMID-200-USG1 product page, North America (November 2, 2026 capture)OfficialHoymilesOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-11-02.

    Location: Page heading, introduction and Features

    Retrieved

    Hoymiles' own North America product page for the HMID-200-USG1, captured on November 2, 2026 at 01:37:48.796 UTC with the paced research fetcher (HTTP 200): an introduction and a Features list; the page has no Tech Specs block. It carries no revision or date. Cited beside Hoymiles' datasheet. Manufacturer claims, not independent tests.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Hoymiles HMID-200-USG1 Microgrid Interconnect Device datasheet (Region: North America, REV1.1) (November 2, 2026 capture)

Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup REV1.1 · 0.66 MB

Archived copy, unaltered, kept as a record of what Hoymiles published. Original address: https://w3oss.hoymiles.com/uploadfile/1/202507/0ebd42d2c9.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
2
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 9893b65ac1f9e999aea6f25f7db28a480a85955bb514459e956efb4f53f40218

Submit a document

Warranty

No warranty terms on file.

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

This category has no Evidence score.

Certificates

Listing stated, none checked

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
HMID-200-USG1

US market

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.