FranklinWH aGate X 1.3.1

By FranklinWHSKU AGT-R1V3-US

No reviews · Write the first

Key specs

Units
SKU
AGT-R1V3-US
Official datasheet
Sources

Published in the data sheet title, "aGate 1.3.1 Datasheet (SKU_ AGT-R1V3-US)", in the availability note on the same page and in the FranklinWH document name. The specification table renders the same string as AGT-RIV3-US; the title spelling is recorded here.

Official datasheet: FranklinWH aGate 1.3.1 Datasheet (SKU: AGT-R1V3-US) October 11, 2025 · Checked · Earlier document

Location: Data sheet document title and SKU row of the performance specifications table

Documented

Enclosure
NEMA Type 3R; Indoor and outdoor rated; Wall mount
Official datasheet
Sources

Printed in the FranklinWH aGate data sheet (PDF page 2) as "Enclosure Type NEMA Type 3R" and "Environment Indoor and outdoor rated" (ENVIRONMENTAL SPECIFICATIONS) and "Mounting Wall mount" (MECHANICAL SPECIFICATIONS). Revised on 1 October 2026: The value now holds the printed Enclosure Type, Environment and Mounting entries word for word, without the row names, which are quoted in the conditions.

Official datasheet: FranklinWH aGate 1.3.1 Datasheet (SKU: AGT-R1V3-US) October 11, 2025 · Checked · Earlier document

Location: Data sheet ENVIRONMENTAL SPECIFICATIONS, "Enclosure Type" and "Environment" rows; MECHANICAL SPECIFICATIONS, "Mounting" row (PDF page 2)

Documented

Safety listing
UL 1741, UL 1741 PCS, UL 67, UL 869A, UL 916, CAN / CSA C22.2 No. 107.1-16, CSA C22.2 No. 29, CSA C22.2 No. 0.19; AC 156, OSHPD, IEEE 693-2005 (high); Franklin Home Power Solution FCC Part 15 Class B, ICES 003
Official datasheet
Sources

Printed in the FranklinWH aGate data sheet, COMPLIANCE INFORMATION (PDF page 2): "Certifications UL 1741, UL 1741 PCS, UL 67, UL 869A, UL 916, CAN / CSA C22.2 No. 107.1-16, CSA C22.2 No. 29, CSA C22.2 No. 0.19", "Seismic AC 156, OSHPD, IEEE 693-2005 (high)" and "Emissions Franklin Home Power Solution FCC Part 15 Class B, ICES 003". Revised on 1 October 2026: The value now holds the printed Certifications, Seismic and Emissions entries word for word, without the row names, which are quoted in the conditions.

Official datasheet: FranklinWH aGate 1.3.1 Datasheet (SKU: AGT-R1V3-US) October 11, 2025 · Checked · Earlier document

Location: Data sheet COMPLIANCE INFORMATION, "Certifications", "Seismic" and "Emissions" rows (PDF page 2)

Documented

Service voltage
120/208 V and 120/240 V, 60 Hz, 2 W+N+PE
Official datasheet
Sources

Published as the nominal alternating-current voltage and phase configuration. The device is AC-coupled.

Official datasheet: FranklinWH aGate 1.3.1 Datasheet (SKU: AGT-R1V3-US) October 11, 2025 · Checked · Earlier document

Location: Data sheet PERFORMANCE SPECIFICATIONS, Nominal AC Voltage and Phase rows

Documented

PV and storage ports
One solar input at 80 A maximum overcurrent protection device and one aPower battery port at 125 A maximum overcurrent protection device; optional Smart Circuits give either one 80 A plus one 50 A circuit at 208/240 V, or one 80 A at 208/240 V plus two 50 A at 120 V
Official datasheet
Sources

AC-coupled throughout: the solar input takes the output of a separate solar inverter, not a photovoltaic array. The Smart Circuits Module is optional.

Official datasheet: FranklinWH aGate 1.3.1 Datasheet (SKU: AGT-R1V3-US) October 11, 2025 · Checked · Earlier document

Location: Data sheet PERFORMANCE SPECIFICATIONS, Solar Input, aPower and Smart Circuits rows

Documented

Maximum current
200 A
Official datasheet
Sources

Maximum grid input overcurrent protection device. The backup and non-backup load ports and the generator port carry the same 200 A maximum; the internal busbar is rated 280 A and the maximum supply fault current 22 kA. The product page presents the 280 A busbar as what lets a home avoid a main panel upgrade.

Official datasheet: FranklinWH aGate 1.3.1 Datasheet (SKU: AGT-R1V3-US) October 11, 2025 · Checked · Earlier document

Location: Data sheet PERFORMANCE SPECIFICATIONS, Grid Input Over Current Protection Device and Busbar Rating rows

Documented

Generator input
One generator port at 200 A maximum overcurrent protection device, available through the optional Generator Module, supporting standby and portable generators and vehicle-to-load
Official datasheet
Sources

The data sheet footnotes that the Generator Module is optional, so a unit without that module has no generator input.

Official datasheet: FranklinWH aGate 1.3.1 Datasheet (SKU: AGT-R1V3-US) October 11, 2025 · Checked · Earlier documentOfficial product page: FranklinWH aGate product page Checked · Earlier document

Location: Data sheet PERFORMANCE SPECIFICATIONS, Generator Over Current Protection Device row and footnote 1

Documented

3 specs not documented yet: rated capacity, usable capacity, dimensionsHelp fill in ›

All specs9
Rated capacity
Not documented
Usable capacity
Not documented

Lifetime production

Not published

Published claims and calculations are not independently tested lifetime output.

Published claims and calculations, not independent test results.

Documents

2 on file
  • WEB
    FranklinWH aGate 1.3.1 Datasheet (SKU: AGT-R1V3-US)OfficialFranklinWH Energy StorageOfficial datasheetOctober 11, 2025
    Source details
    Revision
    Not stated
    Revision date
    October 11, 2025

    The specification table renders the stock keeping unit as AGT-RIV3-US; the document title and the publisher’s own document name spell it AGT-R1V3-US.

    Location: Cover feature list; PERFORMANCE SPECIFICATIONS; MECHANICAL SPECIFICATIONS; COMPLIANCE INFORMATION; ENVIRONMENTAL SPECIFICATIONS; document title "aGate 1.3.1 Datasheet (SKU_ AGT-R1V3-US)"

    Retrieved

    Recorded document/effective date: Oct 11, 2025

    Manufacturer data sheet dated 11 October 2025, served as a PDF from the FranklinWH documentation centre and downloaded on 21 September 2026. It records the ratings FranklinWH publishes for this stock keeping unit; the certification list is the manufacturer’s own statement, and the sheet says the document is for informational purposes and data are subject to change.

    Archived copies

    Archived copy of a document published by FranklinWH Energy Storage. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 0.29 MB

    Archived copy, unaltered, kept as a record of what FranklinWH Energy Storage published. Original address: https://www.franklinwh.com/document/agate-1_3_1-datasheet-sku-agt-r1v3-us. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Printed revision date: 2025-10-11

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 15692fb14430959cbf70609ef0ede9c3afe882985e0c553948aa5058e66a33c6

    Open
  • WEB
    FranklinWH aGate product pageOfficialFranklinWH Energy StorageOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    The Specs tab on this page is rendered client-side and carries no content in the served HTML.

    Location: Headline "280 A busbar to Avoid Main Panel Upgrade"; page banner image

    Retrieved

    Manufacturer-operated product page read on 21 September 2026. It is a marketing overview with no specification table and no model or stock keeping unit printed in the served markup, so only the busbar rating and the photograph it publishes are taken from it; the ratings come from the FranklinWH data sheets instead.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

FranklinWH aGate 1.3.1 Datasheet (SKU: AGT-R1V3-US)

Archived copy of a document published by FranklinWH Energy Storage. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 0.29 MB

Archived copy, unaltered, kept as a record of what FranklinWH Energy Storage published. Original address: https://www.franklinwh.com/document/agate-1_3_1-datasheet-sku-agt-r1v3-us. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Printed revision date: 2025-10-11

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 15692fb14430959cbf70609ef0ede9c3afe882985e0c553948aa5058e66a33c6

Submit a document

Warranty

Product warranty
12 years
Official datasheet
Sources

Published as a 12-year limited warranty on both the cover and the specification table. Coverage, eligibility and remedies are set by the FranklinWH warranty policy, which was not read.

Official datasheet: FranklinWH aGate 1.3.1 Datasheet (SKU: AGT-R1V3-US) October 11, 2025 · Checked · Earlier document

Location: Data sheet cover feature list and PERFORMANCE SPECIFICATIONS Warranty row

Documented

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

This category has no Evidence score.

Certificates

Listing stated, none checked

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
aGate X (US)

Manufacturer SKU AGT-R1V3-US · US market

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.