Fox ESS Meter Collar Hub

By Fox ESSSKU not documented

No reviews · Write the first

Key specs

Units
Weight
1.5 kg3.3 lb converted
Official datasheet
Sources

Printed as "3.3 / 1.5" in the row "Weight [lbs / kg]".

Official datasheet: Fox ESS datasheet (US): Meter Collar Hub, V1.1 | 2026/06/24 Rev V1.1 | 2026/06/24 · Checked · Earlier document

Location: Page 2, Installation specifications, Weight [lbs / kg]

Documented

Dimensions
4.24 L
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 192 × H: 260 × D: 85 mmW: 7.56 × H: 10.2 × D: 3.3 in convertedOfficial datasheet
Sources

Printed as "7.6*10.2*3.3 / 192*260*85" in the row "Dimensions (W*H*D) [in / mm]"; the millimeter figures are the ones printed.

Official datasheet: Fox ESS datasheet (US): Meter Collar Hub, V1.1 | 2026/06/24 Rev V1.1 | 2026/06/24 · Checked · Earlier document

Location: Page 2, Installation specifications, Dimensions (W*H*D) [in / mm]

Calculated

Enclosure
Type 3R
Official datasheet
Sources

Printed as "Type 3R" in the row "Protection Rating".

Official datasheet: Fox ESS datasheet (US): Meter Collar Hub, V1.1 | 2026/06/24 Rev V1.1 | 2026/06/24 · Checked · Earlier document

Location: Page 2, Installation specifications, Protection Rating

Documented

Communications
CAN; RS485
Official datasheet
Sources

Printed as "CAN, RS485 with FOX US/AIO US series inverter" and "Reserved CAN communicaiton ports" (spelling as printed).

Official datasheet: Fox ESS datasheet (US): Meter Collar Hub, V1.1 | 2026/06/24 Rev V1.1 | 2026/06/24 · Checked · Earlier document

Location: Page 2, Features, Communication

Documented

Safety listing
UL1741, UL3141 certification together with PCS system; FCC part 15 class B
Official datasheet
Sources

Printed as "UL1741, UL3141 certification together with PCS system" (Safety) and "FCC part 15 class B" (Emissions); the listing is printed as together with the inverter (PCS) system, not for the box alone. Manufacturer compliance claims; no certificate was checked.

Official datasheet: Fox ESS datasheet (US): Meter Collar Hub, V1.1 | 2026/06/24 Rev V1.1 | 2026/06/24 · Checked · Earlier document

Location: Page 2, Standard compliance, Safety and Emissions

Documented

Operating temperature
-40 to 50 °C-40 to 122 °F converted
Official datasheet
Sources

Printed as "–40 ~ +122 / –40 ~ +50" in the row "Operating Temeprature Range [°F / °C]" (spelling as printed).

Official datasheet: Fox ESS datasheet (US): Meter Collar Hub, V1.1 | 2026/06/24 Rev V1.1 | 2026/06/24 · Checked · Earlier document

Location: Page 2, Installation specifications, Operating Temperature Range [°F / °C]

Documented

2 specs not documented yet: rated capacity, usable capacityHelp fill in ›

All specs8
Rated capacity
Not documented
Usable capacity
Not documented

Lifetime production

Not published

Published claims and calculations are not independently tested lifetime output.

Published claims and calculations, not independent test results.

Documents

1 on file
  • PDF
    Fox ESS datasheet (US): Meter Collar Hub, V1.1 | 2026/06/24OfficialFox ESSOfficial datasheet
    Source details
    Revision
    V1.1 | 2026/06/24
    Revision date
    Not stated

    Archived copy captured on 2026-10-27.

    Location: Page 2, Technical specifications table; page 1, product figure

    Retrieved

    FOXESS CO., LTD.'s own two-page datasheet (PDF) on us.fox-ess.com, linked from the Downloads > Datasheets page of us.fox-ess.com, captured on October 27, 2026. The page 2 table is read from the rendered page: the PDF text layer prints the row labels and the column values in separate runs, so each cited value is quoted as it appears in the text layer and its row and column were confirmed on the rendered page. Manufacturer document, not an independent test.

    Archived copies

    Archived copy of a document published by Fox ESS. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup V1.1 | 2026/06/24 · 0.13 MB

    Archived copy, unaltered, kept as a record of what Fox ESS published. Original address: https://us.fox-ess.com/Public/Uploads/uploadfile/files/20261009/USmetercollarhubDatasheetV1.120260624.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    2
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: eb5095a120881e665fdcd3cde1abe189e211553b6e810565e13d1b0655176558

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Fox ESS datasheet (US): Meter Collar Hub, V1.1 | 2026/06/24

Archived copy of a document published by Fox ESS. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup V1.1 | 2026/06/24 · 0.13 MB

Archived copy, unaltered, kept as a record of what Fox ESS published. Original address: https://us.fox-ess.com/Public/Uploads/uploadfile/files/20261009/USmetercollarhubDatasheetV1.120260624.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
2
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: eb5095a120881e665fdcd3cde1abe189e211553b6e810565e13d1b0655176558

Submit a document

Warranty

No warranty terms on file.

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

This category has no Evidence score.

Certificates

Listing stated, none checked

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
Meter Collar Hub

US market

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.