Charged Reviews · Quick reference
Victron Energy Quattro 48/5000/70-100/100
- Brand
- Victron Energy
- Model
- Quattro 48/5000/70-100/100
- SKU / part number
- QUA485021010[1]
- Category
- Inverters

AC output
| Continuous output | 4 kW[2]Calculated |
|---|---|
| Peak output | 10000 W[2] |
| AC configuration | 230 VAC[2] |
| AC output voltage | ? |
| AC frequency | 50 Hz[25] |
| Grid pass-through | ? |
| Maximum output per leg | ? |
Battery
| Battery voltage | 48 V[25] |
|---|---|
| Battery voltage range | 38 to 66 V[25] |
| Maximum charge current | 70 A[25] |
| Maximum discharge current | ? |
| Battery-only output | ? |
| Maximum grid charging | ? |
| Compatible batteries / BMS | ? |
PV input
| PV array limit (connected) | ? |
|---|---|
| PV input limit (converted) | ? |
| Maximum PV voltage (Voc) | ? |
| MPPT voltage range | ? |
| MPPT trackers | ? |
| String inputs per MPPT | ? |
| PV current per MPPT | ? |
| PV short-circuit current | ? |
| PV startup voltage | ? |
Efficiency and modes
| Peak efficiency | 95 %[25] |
|---|---|
| CEC weighted efficiency | ? |
| Battery conversion efficiency | ? |
| Grid / off-grid modes | ? |
| Generator input | ? |
| Transfer time | ? |
| Idle consumption | 35 W[25] |
| Parallel units | 6[24] |
Communication and environment
| Communications | VE.Bus[25] |
|---|---|
| Operating temperature | -20 to 60 °C[25] |
| Enclosure rating | IP20[25] |
| Operating noise | ? |
Mechanical
| Dimensions | 240 D × 328 W × 444 H mm[25] |
|---|---|
| Weight | 30 kg / 66.14 lb[25] |
Installation (from the manual)
Torque
| Terminal torque | 14 N·m(123.91 in-lb*)[24] |
|---|---|
| AC terminal torque | ? |
| Battery terminal torque | ? |
| PV terminal torque | ? |
| Ground terminal torque | ? |
Conductors
| Battery conductors | 1x 70 mm² (cables 0 to 5 m); 2x 70 mm² (5 to 10 m)[24] |
|---|---|
| AC input conductors | ? |
| AC output conductors | ? |
| PV conductors | ? |
| Ground conductor | ? |
Protection
| Breakers / fuses | DC fuse 200 A; AC-in-1 fuse or magnetic circuit breaker rated at 100 A or less; AC-out-2 fuse or circuit breaker rated at max. 50 A[24] |
|---|---|
| AC input breaker | ? |
| AC output breaker | ? |
| Battery fuse or breaker | ? |
| PV disconnect | ? |
Not in the manual: Clearances and orientation, Grounding, Communication
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.