Victron Energy Quattro 24/5000/120-100/100 120V
- Brand
- Victron Energy
- Model
- Quattro 24/5000/120-100/100 120V
- SKU / part number
- QUA245023110 [1]
- Category
- Inverters
chargedreviews.com/inverters/victron-energy-quattro-24-5000-120-100-100-120v
AC output
Battery
PV input
- PV array limit (connected)
- ?
- PV input limit (converted)
- ?
- Maximum PV voltage (Voc)
- ?
- MPPT voltage range
- ?
- MPPT trackers
- ?
- String inputs per MPPT
- ?
- PV current per MPPT
- ?
- PV short-circuit current
- ?
- PV startup voltage
- ?
Efficiency and modes
- Peak efficiency
- 94 % [4]
- CEC weighted efficiency
- ?
- Battery conversion efficiency
- ?
- Grid / off-grid modes
- ?
- Generator input
- Programmable relays which can be set for general alarm, DC undervoltage or genset start signal function [3]
- Transfer time
- 20 ms [2]
- Idle consumption
- 30 W [4]
- Standby consumption
- 10 W [2]
- Parallel units
- 6 count [5]
Communication and environment
Mechanical
Installation (from the manual)
Torque
- Terminal torque
- 14 N·m [5]
- AC terminal torque
- ?
- Battery terminal torque
- ?
- PV terminal torque
- ?
- Ground terminal torque
- ?
Conductors
Protection
- Breakers / fuses
- DC fuse 400 A; AC-in-1 fuse or magnetic circuit breaker rated at 100 A or less; AC-out-2 fuse or circuit breaker rated at max. 50 A [5]
- AC input breaker
- AC-in-1 and AC-in-2: fuse or magnetic circuit breaker rated at 100 A or less [3]
- AC output breaker
- AC-out-1: an adequately rated UL 943 compliant residual current circuit breaker (RCCD) and fuse or circuit breaker rated to support the expected load, in series with the output. AC-out-2: an UL 943 compliant residual current circuit breaker (RCCD) and fuse or circuit breaker rated at max. 50 A, in series with AC-out-2. [3]
- Battery fuse or breaker
- Recommended DC fuse 400 A. The Quattro has no internal DC fuse; the DC fuse should be installed outside the Quattro. [3]
- PV disconnect
- ?
Clearances and orientation
Grounding
- Grounding and neutral-ground bonding
- The Quattro is a safety class I product (supplied with an ground terminal for safety purposes).; In a fixed installation, an uninterruptable grounding can be secured by means of the grounding wire of the AC input. Otherwise the casing must be grounded.; In a mobile installation, the casing must be connected to the chassis (of the vehicle) or to the hull or grounding plate (of the boat). [3]
Communication
- Communication ports
- VE.Bus communication port: for parallel and three phase operation, remote monitoring and system integration; General purpose comm. port: Yes, 2x [3]