Charged Reviews · Quick reference
Victron Energy MultiPlus-II 48/6k5/100-50 GX
- Brand
- Victron Energy
- Model
- MultiPlus-II 48/6k5/100-50 GX
- SKU / part number
- PMP482606000[1]
- Category
- Inverters

AC output
| Continuous output | 6 kW[2] |
|---|---|
| Peak output | 11 kW/1min[2] |
| AC configuration | 230 V AC[2] |
| AC output voltage | ? |
| AC frequency | 50 Hz[17] |
| Grid pass-through | 50 A[16] |
| Maximum output per leg | ? |
Battery
| Battery voltage | 48 V[17] |
|---|---|
| Battery voltage range | 38 to 60 V[17] |
| Maximum charge current | 100 A[17] |
| Maximum discharge current | ? |
| Battery-only output | ? |
| Maximum grid charging | ? |
| Compatible batteries / BMS | ? |
PV input
| PV array limit (connected) | ? |
|---|---|
| PV input limit (converted) | ? |
| Maximum PV voltage (Voc) | ? |
| MPPT voltage range | ? |
| MPPT trackers | ? |
| String inputs per MPPT | ? |
| PV current per MPPT | ? |
| PV short-circuit current | ? |
| PV startup voltage | ? |
Efficiency and modes
| Peak efficiency | 96 %[16] |
|---|---|
| CEC weighted efficiency | ? |
| Battery conversion efficiency | ? |
| Grid / off-grid modes | ? |
| Generator input | ? |
| Transfer time | ? |
| Idle consumption | 28 W[17] |
| Parallel units | 6[16] |
Communication and environment
| Communications | VE.Bus[17] |
|---|---|
| Operating temperature | -40 to 65 °C[17] |
| Enclosure rating | IP21[17] |
| Operating noise | ? |
Mechanical
| Dimensions | 150 D × 320 W × 644 H mm[17] |
|---|---|
| Weight | 29 kg / 63.93 lb[17] |
Installation (from the manual)
Conductors
| Battery conductors | 70 mm² (cables 0 to 5 m); 95 mm² (5 to 10 m)[16] |
|---|---|
| AC input conductors | ? |
| AC output conductors | ? |
| PV conductors | ? |
| Ground conductor | ? |
Protection
| Breakers / fuses | DC fuse 250 A[16] |
|---|---|
| AC input breaker | ? |
| AC output breaker | ? |
| Battery fuse or breaker | ? |
| PV disconnect | ? |
Not in the manual: Torque, Clearances and orientation, Grounding, Communication
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.