Charged Reviews · Quick reference
Victron Energy MultiPlus-II 48/3000/35-50 120V
- Brand
- Victron Energy
- Model
- MultiPlus-II 48/3000/35-50 120V
- SKU / part number
- PMP482305100[1]
- Category
- Inverters
AC output
| Continuous output | 2.4 kW[3]Calculated |
|---|---|
| Peak output | 5500 W[3] |
| AC configuration | 120 VAC[3] |
| AC output voltage | 120 V[13] |
| AC frequency | 60 Hz[14] |
| Grid pass-through | 50 A[14] |
| Maximum output per leg | ? |
Battery
| Battery voltage | 48 V[14] |
|---|---|
| Battery voltage range | 38 to 66 V[14] |
| Maximum charge current | 35 A[14] |
| Maximum discharge current | ? |
| Battery-only output | ? |
| Maximum grid charging | 35 A[13] |
| Compatible batteries / BMS | ? |
PV input
| PV array limit (connected) | ? |
|---|---|
| PV input limit (converted) | ? |
| Maximum PV voltage (Voc) | ? |
| MPPT voltage range | ? |
| MPPT trackers | ? |
| String inputs per MPPT | ? |
| PV current per MPPT | ? |
| PV short-circuit current | ? |
| PV startup voltage | ? |
Efficiency and modes
| Peak efficiency | 95 %[14] |
|---|---|
| CEC weighted efficiency | ? |
| Battery conversion efficiency | ? |
| Grid / off-grid modes | ? |
| Generator input | Programmable relay can be set for genset start/stop[13] |
| Transfer time | ? |
| Idle consumption | 11 W[14] |
| Parallel units | 6[13] |
Communication and environment
| Communications | VE.Bus[14] |
|---|---|
| Operating temperature | -40 to 65 °C[14] |
| Enclosure rating | IP21[13]Needs confirmation |
| Operating noise | ? |
Mechanical
| Dimensions | 147 D × 277 W × 572 H mm[14] |
|---|---|
| Weight | 19 kg / 41.89 lb[14] |
Installation (from the manual)
Torque
| Terminal torque | 12 N·m(106.21 in-lb*)[13] |
|---|---|
| AC terminal torque | ? |
| Battery terminal torque | ? |
| PV terminal torque | ? |
| Ground terminal torque | ? |
Conductors
| Battery conductors | AWG 1 (cables 0 to 5 m); AWG 2/0 (5 to 10 m)[13] |
|---|---|
| AC input conductors | AWG 6 minimum[13] |
| AC output conductors | AWG 6 minimum (AC-out-1); AWG 10 minimum (AC-out-2)[13] |
| PV conductors | ? |
| Ground conductor | At least 4mm²[13] |
Protection
| Breakers / fuses | DC fuse 125 A; AC-in 50 A, AC-out-1 50 A, AC-out-2 32 A fuse or circuit breaker[13] |
|---|---|
| AC input breaker | AC-in: 50 A fuse or circuit breaker[13] |
| AC output breaker | AC-out-1: 50 A; AC-out-2: 32 A (fuse or circuit breaker)[13] |
| Battery fuse or breaker | DC fuse 125A[13] |
| PV disconnect | ? |
Clearances and orientation
| Installation clearances | ? |
|---|---|
| Mounting orientation | Suitable for wall mounting[13] |
Grounding
| Grounding and neutral-ground bonding | This product is a safety class I device (supplied with a ground terminal for safety purposes).; Its AC input and/or output terminals must be provided with uninterruptible grounding for safety purposes.; An additional grounding point is located on the product's exterior.[13] |
|---|
Communication
| Communication ports | VE.Bus communication port: for parallel, split phase and three phase operation, remote monitoring and system integration; General purpose com. port: Yes, 2x[13] |
|---|
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.