Charged ReviewsSaved 0Compare 0Login

Charged Reviews · Quick reference

Victron Energy MultiPlus-II 12/4k/160-50 2x120V 50/60Hz

Brand
Victron Energy
Model
MultiPlus-II 12/4k/160-50 2x120V 50/60Hz
SKU / part number
PMP122405210 [1]
Category
Inverters
No photo

chargedreviews.com/inverters/victron-energy-multiplus-ii-12-4k-160-50-2x120v-50-60hz

AC output

Continuous output
3.4 kW [2]
Peak output
6kW/2s [2]
AC configuration
120 VAC [2]
AC output voltage
?
AC frequency
?
Grid pass-through
?
Maximum output per leg
?

Battery

Battery voltage
?
Battery voltage range
?
Maximum charge current
?
Maximum discharge current
?
Battery-only output
?
Maximum grid charging
?
Compatible batteries / BMS
?

PV input

PV array limit (connected)
?
PV input limit (converted)
?
Maximum PV voltage (Voc)
?
MPPT voltage range
?
MPPT trackers
?
String inputs per MPPT
?
PV current per MPPT
?
PV short-circuit current
?
PV startup voltage
?

Efficiency and modes

Peak efficiency
93 % [3]
CEC weighted efficiency
?
Battery conversion efficiency
?
Grid / off-grid modes
?
Generator input
Programmable relay can be set for genset start/stop [3]
Transfer time
?
Idle consumption
18 W [3]
Parallel units
6 count [3]

Communication and environment

Communications
?
Operating temperature
?
Enclosure rating
IP22 [3]
Operating noise
?

Mechanical

Dimensions
W 277 × H 659 × D 166 mm / W 10.9 × H 25.9 × D 6.54 in converted [4]
Weight
25 kg / 55 lb converted [3]

Installation (from the manual)

Torque

Terminal torque
12 N·m [3]
AC terminal torque
?
Battery terminal torque
?
PV terminal torque
?
Ground terminal torque
?

Conductors

Battery conductors
2x AWG 2/0 (cables 0 to 5 m); 2x AWG 4/0 (5 to 10 m) [3]
AC input conductors
AWG 6 minimum [3]
AC output conductors
AWG 6 minimum (AC-out-1); AWG 6 minimum (AC-out-2) [3]
PV conductors
?
Ground conductor
?

Protection

AC input breaker
?
AC output breaker
?
Battery fuse or breaker
?
PV disconnect
?

Not in the manual: Clearances and orientation, Grounding, Communication

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

Victron Energy MultiPlus-II 12/4k/160-50 2x120V 50/60Hz · MultiPlus-II 12/4k/160-50 2x120V 50/60Hz

Warranty

Warranty term5 years[5]
Optional extension5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term ends[5]
Coverage startsDate of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date[5]
Coverage conditionsVoid after physical damage or alteration; excludes improper use such as reversed battery polarity, inadequate connection, mechanical shock, liquid or condensation, unsuitable environment, lightning, and terminals damaged by insufficient tightening; not for products misused, neglected, improperly installed, disassembled, modified or repaired by anyone other than Victron Energy or its authorized Repair Centres[5]
RemedyRepair, replace or (partly) credit the defective product free of charge, at Victron Energy's discretion[5]
Labor and shippingNot included: the warranty does not perform or reimburse de-installation, transportation and re-installation[5]
Transfer to another owner?
Registration?
Territory?

Certifications and listings

UL 1741?
UL 1741 SA?
UL 1741 SB?
IEEE 1547?
CA Rule 21?
UL 9540?
FCC Part 15?
EN 55014-1Claimed present at observation [2]
EN 55014-2Claimed present at observation [2]
EN-IEC 60335-1Claimed present at observation [2]
EN-IEC 60335-2-29Claimed present at observation [2]
EN-IEC 61000-3-2Claimed present at observation [2]
EN-IEC 61000-3-3Claimed present at observation [2]
IEC 61000-6-1Claimed present at observation [2]
IEC 61000-6-2Claimed present at observation [2]
IEC 61000-6-3Claimed present at observation [2]
UL 458Claimed present at observation [2]

Documents and sources

  1. Victron Energy price list 2026-Q3 (EUR C, web edition) Manufacturer price list · Revision 2026-Q3 · Checked Sep 22, 2026 https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf
  2. MultiPlus-II 2x120V Manufacturer datasheet (PDF) · Checked Sep 18, 2026 https://www.victronenergy.com/upload/documents/Datasheet-MultiPlus-II-2x120V-EN-.pdf
  3. MultiPlus-II 2x120V manual Manufacturer installation manual · Checked Sep 25, 2026 https://www.victronenergy.com/upload/documents/MultiPlus-II_2x120V/32424-MultiPlus-II___Quattro-II-pdf-en.pdf
  4. Victron Energy price list EUR C, 2026 Q3 Price list · Revision 2026-Q3 · Checked Sep 19, 2026 https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf
  5. Victron Energy victron warranty Manufacturer warranty policy · Checked Sep 10, 2026 https://www.victronenergy.com/upload/documents/Victron-Energy-Limited-Warranty-Policy.pdf

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/inverters/victron-energy-multiplus-ii-12-4k-160-50-2x120v-50-60hzSome links pay us a commission. That does not affect what we record.