Brand
Victron Energy
Model
MultiPlus 12/2000/80-50 120V (UL 458)
SKU / part number
PMP122200102 [1]
Category
Inverters

chargedreviews.com/inverters/victron-energy-multiplus-12-2000-80-50-120v-ul-458

AC output

Continuous output
1.6 kW [2]
Peak output
3500 W [2]
AC configuration
120 VAC [2]
AC output voltage
?
AC frequency
60 Hz [3]
Grid pass-through
50 A [3]
Maximum output per leg
?

Battery

Battery voltage
12 V [3]
Battery voltage range
[9.5, 17] VDC V [3]
Maximum charge current
80 A [3]
Maximum discharge current
?
Battery-only output
?
Maximum grid charging
?
Compatible batteries / BMS
?

PV input

PV array limit (connected)
?
PV input limit (converted)
?
Maximum PV voltage (Voc)
?
MPPT voltage range
?
MPPT trackers
?
String inputs per MPPT
?
PV current per MPPT
?
PV short-circuit current
?
PV startup voltage
?

Efficiency and modes

Peak efficiency
93 % [3]
CEC weighted efficiency
?
Battery conversion efficiency
?
Grid / off-grid modes
?
Generator input
Multi-functional relay, by default programmed as an alarm relay; it can be programmed for other applications, for example to start a generator (VEConfigure software needed) [4]
Transfer time
?
Idle consumption
10 W [3]
Parallel units
6 count [4]

Communication and environment

Communications
VE.Bus [3]
Operating temperature
[-40, 65] °C °C [3]
Enclosure rating
IP22 [3]
Operating noise
?

Mechanical

Dimensions
W 236 × H 506 × D 147 mm / W 9.29 × H 19.9 × D 5.79 in converted [3]
Weight
15.5 kg / 34.2 lb converted [3]

Installation (from the manual)

Torque

Terminal torque
12 N·m [4]
AC terminal torque
1.6 N·m [4]
Battery terminal torque
?
PV terminal torque
?
Ground terminal torque
?

Conductors

Battery conductors
70 mm² (cables 0 to 5 m); 95 mm² (5 to 10 m) [4]
AC input conductors
Three-wire cable with a flexible core and a cross section of at least 6 mm² [4]
AC output conductors
?
PV conductors
?
Ground conductor
?

Protection

AC input breaker
?
AC output breaker
?
Battery fuse or breaker
Recommended DC fuse 300A; NO internal DC Fuses [4]
PV disconnect
?

Clearances and orientation

Installation clearances
There should be a clear space of at least 10cm around the appliance for cooling. [4]
Mounting orientation
?

Grounding

Grounding and neutral-ground bonding
This is a Safety Class I product (supplied with a protective grounding terminal).; Uninterruptible protective grounding must be provided at the AC input and/or output terminals and/or chassis grounding point located externally on the product.; In a fixed installation, uninterruptable grounding can be secured by means of the grounding wire of the AC input. Otherwise the casing must be grounded. [4]

Not in the manual: Communication

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

Victron Energy MultiPlus 12/2000/80-50 120V · MultiPlus 12/2000/80-50 120V (UL 458)

Warranty

Warranty term5 years[5]
Optional extension5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term ends[5]
Coverage startsDate of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date[5]
Coverage conditionsVoid after physical damage or alteration; excludes improper use such as reversed battery polarity, inadequate connection, mechanical shock, liquid or condensation, unsuitable environment, lightning, and terminals damaged by insufficient tightening; not for products misused, neglected, improperly installed, disassembled, modified or repaired by anyone other than Victron Energy or its authorized Repair Centres[5]
RemedyRepair, replace or (partly) credit the defective product free of charge, at Victron Energy's discretion[5]
Labor and shippingNot included: the warranty does not perform or reimburse de-installation, transportation and re-installation[5]
Transfer to another owner?
Registration?
Territory?

Certifications and listings

UL 1741?
UL 1741 SA?
UL 1741 SB?
IEEE 1547?
CA Rule 21?
UL 9540?
FCC Part 15?
ECE R10-5Claimed [3]
EN-IEC 60335-1Claimed [3]
EN-IEC 60335-2-29Claimed [3]
EN-IEC 62109-1Claimed [3]

Documents and sources

  1. Victron Energy price list 2026-Q3 (EUR C, web edition) Manufacturer price list · Revision 2026-Q3 · Checked Sep 22, 2026 https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf
  2. MultiPlus 2000VA 120V Manufacturer datasheet (PDF) · Checked Sep 18, 2026 https://www.victronenergy.com/upload/documents/Datasheet-MultiPlus-2000VA-120V-EN.pdf
  3. Victron Energy public API record for SKU PMP122200102 (MultiPlus 2000VA) Manufacturer product API record · Revision 2026-09-04 19:04:37 · Checked Sep 18, 2026 https://www.victronenergy.com/api/v1/product/sku/PMP122200102?format=json
  4. MultiPlus 2kVA manual Manufacturer installation manual · Checked Sep 25, 2026 https://www.victronenergy.com/upload/documents/MultiPlus_2kVA_120V/24547-MultiPlus_2kVA-pdf-en.pdf
  5. Victron Energy victron warranty Manufacturer warranty policy · Checked Sep 10, 2026 https://www.victronenergy.com/upload/documents/Victron-Energy-Limited-Warranty-Policy.pdf

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/inverters/victron-energy-multiplus-12-2000-80-50-120v-ul-458Some links pay us a commission. That does not affect what we record.