Charged Reviews · Quick reference
Victron Energy Inverter 48/1200 VE.Direct NEMA GFCI
- Brand
- Victron Energy
- Model
- Inverter 48/1200 VE.Direct NEMA GFCI (UL 458)
- SKU / part number
- PIN482122510 [1]
- Category
- Inverters
chargedreviews.com/inverters/victron-energy-inverter-48-1200-ve-direct-nema-gfci-ul-458
AC output
Battery
PV input
- PV array limit (connected)
- ?
- PV input limit (converted)
- ?
- Maximum PV voltage (Voc)
- ?
- MPPT voltage range
- ?
- MPPT trackers
- ?
- String inputs per MPPT
- ?
- PV current per MPPT
- ?
- PV short-circuit current
- ?
- PV startup voltage
- ?
Efficiency and modes
Communication and environment
Mechanical
Installation (from the manual)
Conductors
Protection
- Breakers / fuses
- Internal DC fuse 60 A (BF1 58 V, replaceable); add a fuse or DC circuit breaker close to the battery if the DC cable is longer than 1.5 m (always for UL NEMA GFCI models) [5]
- AC input breaker
- ?
- AC output breaker
- ?
- Battery fuse or breaker
- Internal DC fuse 60 A, fuse type BF1 58 V [6]
- PV disconnect
- ?
Clearances and orientation
- Installation clearances
- Leave at least 10 centimetres clearance around the inverter. [6]
- Mounting orientation
- Base mounting: OK. Vertical wall mounting, fan at bottom: OK. Horizontal wall mounting: OK. Ceiling mounting (inverted): Not recommended. Vertical wall mounting, fan on top: Not recommended. [6]
Grounding
- Grounding and neutral-ground bonding
- This is a Safety Class I product (supplied with a protective grounding terminal).; The chassis must be grounded.; A grounding point is located on the outside of the product. [6]
Communication
- Communication ports
- VE.Direct port [6]
Not in the manual: Torque