Charged ReviewsSaved 0Compare 0Login
Trace Engineering
Inverter charger

Trace Engineering SW4048J Sine Wave Inverter/Charger

Key specs

Weight48 kg / 110 lb converted
Nominal voltage48 V DC
Efficiency95 %
Max charge60 A
AC frequency50 Hz

All specifications

Identity

BrandTrace Engineering · Website
ModelSW4048J
MarketUnknown
Manufacturer SKUSW4048J
About brandTrace Engineering Company, Inc., of Arlington, Washington, published the SW Series sine wave inverter/chargers, including the SW4048. Its SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999) is now kept by Xantrex in the discontinued products section of the xantrex.com library.
SKU detail
locator: Specifications and Features (50 Hz Models), MODEL row
conditions: Model number as printed by Trace Engineering in the 50 Hz specifications table of its SW Series owner's manual.
Sources: [1]
FieldValueConditionsSource
Weight48 kg / 110 lb converted
Printed as "105 lbs (48 kg)" inverter only. Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Weight - Inverter Only row
[1]
Voltage thd3 to 5% (stand alone operation)
Printed as "3 to 5% (stand alone operation)" in a row that spans every model of the table, including the SW4048J.
Where: Specifications and Features (50 Hz Models), AC Output Characteristics
[1]
AC voltage105 vac
Printed as "105 vac" RMS output. Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), AC Output Voltage (RMS) row
[1]
Max charge60 A
Printed as "60 amps DC" maximum charging rate, 3 stage regulation. Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Maximum Charging Rate row
[1]
DimensionsW 230 × H 380 × L 570 mm / W 9.06 × H 15 × L 22.4 in converted
Printed as "15” (38 cm) high, 22.5” (57 cm) wide, 9” (23 cm) deep (when wall mounted)" in a row that spans every model of the table, including the SW4048J; the centimeter figures are recorded in millimeters, with the 57 cm width as length and the 23 cm depth as width.
Where: Specifications and Features (50 Hz Models), Dimensions - Inverter Only row
Sources
Converted: 57 cm x 10 = 570 mm; 23 cm x 10 = 230 mm; 38 cm x 10 = 380 mm
[1]
Efficiency95 %
Peak efficiency, printed as "95%". Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Efficiency (peak) row
[1]
AC frequency50 Hz
Printed as "50 Hz". Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Nominal Frequency row
[1]
Enclosure ratingIndoor, ventilated, steel chassis with powdercoat finish
Printed as enclosure type "Indoor, ventilated, steel chassis with powdercoat finish" in a row that spans every model of the table, including the SW4048J.
Where: Specifications and Features (50 Hz Models), Enclosure Type row
[1]
Nominal voltage48 V DC
Printed as "48 vdc". Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Nominal DC Input Voltage row
[1]
Grid passthrough60 A
Printed as "60 amps AC" automatic transfer relay. Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Automatic Transfer Relay row
[1]
Idle consumption16 W
Printed as "0.33 A (16 W)" in On Mode with no load; search mode draws "0.025 A (1 W)". Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), DC Input Requirements, On Mode (no load - idle) row
[1]
Continuous AC output33 A
Printed as "33 amps AC" continuous output at 25 °C; maximum output is 78 amps AC (RMS). Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Continuous Output (@ 25 °C) row
[1]
Battery voltage range44 to 66 V
Printed as "44 to 66 vdc". Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), DC Input Requirements, Input Voltage Range row
[1]
Operating temperature-40 to 60 °C / -40 to 140 °F converted
Printed as allowed temperature range "-40 °F to 140 °F (-40 °C to +60 °C)" (output may not meet specified tolerances), in a row that spans every model of the table, including the SW4048J; the specified range, within which output meets tolerances, is 0 °C to +40 °C.
Where: Specifications and Features (50 Hz Models), Environmental Limitations
[1]
Continuous apparent output power4 kVA
Printed as "4000 VA" continuous power at 20 °C, recorded in kVA; the manual prints this rating in volt-amperes only, so no continuous power in watts is recorded. Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Continuous Power @ 20 °C row
Sources
Converted: 4000 VA / 1000 VA per kVA = 4 kVA
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
Not yet documented
Battery voltage
44 to 66 V
Solar input
Not statedMPPT trackers Not stated
AC output
105 vac
Warranty
2 years
Size
49.82 L* (Calculated from published dimensions)W: 230 × H: 380 × L: 570 mm / W: 9.06 × H: 15 × L: 22.4 inWeight 48 kg / 110 lb

Evidence score

2/100Missing details40% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Battery conversion efficiency needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Warranty term2 years2.4 / 30.0

2 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

Printed as "Trace Engineering warrants its power products against defects in materials and workmanship for a period of two (2) years from the date of purchase", extended to all purchasers or owners during the warranty period. The warranty given then by a company that no longer trades under that name.

[1]

Idle consumption16 W0.0 / 10.0

16 against 0.021 W, the lowest documented for an inverter (printed by the maker): Enphase IQ8M Microinverter IQ8M-72-2-US

Printed as "0.33 A (16 W)" in On Mode with no load; search mode draws "0.025 A (1 W)". Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).

[1]

Research pending, 0 points: Certificates, Battery conversion efficiency.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

FieldValueConditionsSource
Warranty term2 years
Printed as "Trace Engineering warrants its power products against defects in materials and workmanship for a period of two (2) years from the date of purchase", extended to all purchasers or owners during the warranty period. The warranty given then by a company that no longer trades under that name.
Where: Warranty/Repair Information, Limited Warranty
[1]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com

Archived copy of a document published by Trace Engineering Company, Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 2.75 MB

Archived copy, unaltered, kept as a record of what Trace Engineering Company, Inc. published. Original address: https://xantrex.com/wp-content/uploads/2023/03/SW2512MC_sw4024mc_OG.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
152

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 8c70ef8b0ef19b29d22186ce53585fb040804a45e6f8b72477d3086cb63f447a

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
SW4048J

Manufacturer SKU SW4048J

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 40
basis: Unknown
missing:
Certificate evidence needed
Battery conversion efficiency needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: 2
unit: Unknown
shown: 2 years
shown detail: Unknown
state: documented
points: 2.4
ceiling: 30
weight: 30
share: 8
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: 16
unit: Unknown
shown: 16 W
shown detail: Unknown
state: documented
points: 0
ceiling: 10
weight: 10
share: 0.1
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com (Trace Engineering Company, Inc. · manufacturer · observed Oct 3, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details