About brandTrace Engineering Company, Inc., of Arlington, Washington, published the SW Series sine wave inverter/chargers, including the SW4048. Its SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999) is now kept by Xantrex in the discontinued products section of the xantrex.com library.
SKU detail
locator: Specifications and Features (50 Hz Models), MODEL row
conditions: Model number as printed by Trace Engineering in the 50 Hz specifications table of its SW Series owner's manual.
Printed as "105 lbs (48 kg)" inverter only. Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Weight - Inverter Only row
Printed as "105 vac" RMS output. Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), AC Output Voltage (RMS) row
Printed as "60 amps DC" maximum charging rate, 3 stage regulation. Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Maximum Charging Rate row
W 230 × H 380 × L 570 mm / W 9.06 × H 15 × L 22.4 in converted
Printed as "15” (38 cm) high, 22.5” (57 cm) wide, 9” (23 cm) deep (when wall mounted)" in a row that spans every model of the table, including the SW4048J; the centimeter figures are recorded in millimeters, with the 57 cm width as length and the 23 cm depth as width.
Where: Specifications and Features (50 Hz Models), Dimensions - Inverter Only row
Sources
Converted: 57 cm x 10 = 570 mm; 23 cm x 10 = 230 mm; 38 cm x 10 = 380 mm
Peak efficiency, printed as "95%". Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Efficiency (peak) row
Printed as "50 Hz". Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Nominal Frequency row
Indoor, ventilated, steel chassis with powdercoat finish
Printed as enclosure type "Indoor, ventilated, steel chassis with powdercoat finish" in a row that spans every model of the table, including the SW4048J.
Where: Specifications and Features (50 Hz Models), Enclosure Type row
Printed as "48 vdc". Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Nominal DC Input Voltage row
Printed as "60 amps AC" automatic transfer relay. Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Automatic Transfer Relay row
Printed as "0.33 A (16 W)" in On Mode with no load; search mode draws "0.025 A (1 W)". Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), DC Input Requirements, On Mode (no load - idle) row
Printed as "33 amps AC" continuous output at 25 °C; maximum output is 78 amps AC (RMS). Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Continuous Output (@ 25 °C) row
Printed as "44 to 66 vdc". Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), DC Input Requirements, Input Voltage Range row
Printed as allowed temperature range "-40 °F to 140 °F (-40 °C to +60 °C)" (output may not meet specified tolerances), in a row that spans every model of the table, including the SW4048J; the specified range, within which output meets tolerances, is 0 °C to +40 °C.
Where: Specifications and Features (50 Hz Models), Environmental Limitations
Printed as "4000 VA" continuous power at 20 °C, recorded in kVA; the manual prints this rating in volt-amperes only, so no continuous power in watts is recorded. Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Where: Specifications and Features (50 Hz Models), Continuous Power @ 20 °C row
49.82 L* (Calculated from published dimensions)W: 230 × H: 380 × L: 570 mm / W: 9.06 × H: 15 × L: 22.4 inWeight48 kg / 110 lb
Evidence score
2/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term2 years2.4 / 30.0
2 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Trace Engineering warrants its power products against defects in materials and workmanship for a period of two (2) years from the date of purchase", extended to all purchasers or owners during the warranty period. The warranty given then by a company that no longer trades under that name.
Printed as "0.33 A (16 W)" in On Mode with no load; search mode draws "0.025 A (1 W)". Read from the SW4048J column (the sixth model column) of the 50 Hz Models specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software).
Research pending, 0 points: Certificates, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Warranty term
2 years
Printed as "Trace Engineering warrants its power products against defects in materials and workmanship for a period of two (2) years from the date of purchase", extended to all purchasers or owners during the warranty period. The warranty given then by a company that no longer trades under that name.
Location: Specifications and Features (60 Hz Models), page 118; Introduction, listings
Retrieved Oct 3, 2026
Trace Engineering's own owner's manual for the SW Series, linked as the SW Series owner's guide in the discontinued products section of Xantrex's xantrex.com library. Its 60 Hz specifications table has a column for the SW4048.
Archived copies
Archived copy of a document published by Trace Engineering Company, Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com
Archived copy of a document published by Trace Engineering Company, Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].