SunGoldPower SPH8048P
- Brand
- SunGoldPower
- Model
- SPH8048P
- SKU / part number
- SPH8048P[5]
- Category
- Inverters

AC output
| Continuous output | 8 kW[2] |
|---|---|
| Peak output | 16,000 W[2] |
| AC configuration | Split-phase mode (default); Single-phase mode[2] |
| AC output voltage | AC output phase voltage (L-N) 100 VAC−120 VAC, 120 VAC (default); AC output line voltage (L-L) 200 VAC−240 VAC, 240 VAC (default)[2] |
| AC frequency | 50/60 Hz[2] |
| Grid pass-through | 63 A[2] |
| Maximum output per leg | ? |
Battery
| Battery voltage | 48 V[2] |
|---|---|
| Battery voltage range | 40 to 60 V[2] |
| Maximum charge current | 180 A[2] |
| Maximum discharge current | ? |
| Battery-only output | ? |
| Maximum grid charging | 100 A[2] |
| Compatible batteries / BMS | Lithium-ion battery/lead-acid battery/user-defined battery[2] |
PV input
| PV array limit (connected) | ? |
|---|---|
| PV input limit (converted) | 11 kW[2]Calculated |
| Maximum PV voltage (Voc) | 500 V[2] |
| MPPT voltage range | 125 to 425 V[2] |
| MPPT trackers | 2[2] |
| String inputs per MPPT | ? |
| PV current per MPPT | 22/22 A[2] |
| PV short-circuit current | ? |
| PV startup voltage | ? |
Efficiency and modes
| Peak efficiency | 92 %[2] |
|---|---|
| CEC weighted efficiency | ? |
| Battery conversion efficiency | 92 %[2] |
| Grid / off-grid modes | ? |
| Generator input | Mains or generator connects to the AC input; dry contact remote generator start/stop[2] |
| Transfer time | 10 ms[2] |
| Idle consumption | ? |
| Parallel units | 6[2] |
Communication and environment
| Communications | RS485; CAN; USB; dry contact[2] |
|---|---|
| Operating temperature | -10 to 55 °C[2] |
| Enclosure rating | IP20[2] |
| Operating noise | ? |
Mechanical
| Dimensions | 620 D × 445 D × 130 D mm[2] |
|---|---|
| Weight | 27 kg / 59.52 lb[2] |
Installation (from the manual)
Conductors
| Battery conductors | 50 mm²/0 AWG[2] |
|---|---|
| AC input conductors | Split-phase mode: 13mm2/8 AWG (L1/L2/N); single-phase mode: 13mm2/8 AWG (L1/L2), 26 mm2/3 AWG (N)[2] |
| AC output conductors | Split-phase mode: 13mm2/8 AWG (L1/L2/N); single-phase mode: 13mm2/8 AWG (L1/L2), 26mm2/3 AWG (N)[2] |
| PV conductors | 4 mm²/12 AWG[2] |
| Ground conductor | not less than 4 mm²[2] |
Protection
| AC input breaker | Split-phase mode: 3P-63A; single-phase mode: 2P-125A[2] |
|---|---|
| AC output breaker | Split-phase mode: 3P-63A; single-phase mode: 2P-125A[2] |
| Battery fuse or breaker | 2P-200A[2] |
| PV disconnect | 2P-25A[2] |
Clearances and orientation
| Installation clearances | Top 500mm, bottom 500mm, left 200mm, right 200mm[2] |
|---|---|
| Mounting orientation | ? |
Grounding
| Grounding and neutral-ground bonding | Please ensure that the grounding terminal is reliably connected to the grounding busbar.[2] |
|---|
Communication
| Communication ports | USB-B port; WIFI port; RS485/CAN port; Dry contact port; Parallel port[2] |
|---|
Not in the manual: Torque
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.