AC output

Continuous output7.6 kW[2]Calculated
Peak output15,200 VA for 1 s[2]
AC configuration?
AC output voltage120 V / 240 V (Split phase) / 208 V (2/3 phase) V AC[2]
AC frequency50 Hz / 60 Hz[2]
Grid pass-through?
Maximum output per leg?

Battery

Battery voltage48 V[2]
Battery voltage range40 to 64 V[2]
Maximum charge current210 A[2]
Maximum discharge current180 A[2]
Battery-only output7.6 kW[2]Calculated
Maximum grid charging?
Compatible batteries / BMSLithium-ion/Lead-acid[2]

PV input

PV array limit (connected)12 kW[2, 4]
PV input limit (converted)?
Maximum PV voltage (Voc)600 V[2]
MPPT voltage range70 to 540 V[2]
MPPT trackers3[2]
String inputs per MPPT?
PV current per MPPT30 A / 22 A / 22 A[2]
PV short-circuit current40 A / 30 A / 30 A[2]
PV startup voltage90 V[2]

Efficiency and modes

Peak efficiency?
CEC weighted efficiency?
Battery conversion efficiency?
Grid / off-grid modesSelf-consumption, Feed-in Priority, Back-up and Off Grid modes[2]
Generator inputYes (GEN port)[2]
Transfer time< 10 ms (typical)[2]
Idle consumption?
Parallel units9[2, 4]

Communication and environment

CommunicationsCAN (for BMS); DRM/RS485 (for meter); RS485; optional: Wi-Fi/LAN[2]
Operating temperature-25 to 60 °C[2]
Enclosure ratingNEMA 3R[2]
Operating noise?

Mechanical

Dimensions240 D × 420 W × 800 H mm[2]
Weight40 kg / 88.18 lb[2]

Installation (from the manual)

Torque

AC terminal torque3.95 N·m(34.96 in-lb*)[2]
Battery terminal torque20 N·m(177.01 in-lb*)[2]
PV terminal torque?
Ground terminal torque3.95 N·m(34.96 in-lb*)[2]

Conductors

Battery conductors3/0 AWG[2]
AC input conductorsMin. 6 AWG[2]
AC output conductorsMin. 6 AWG[2]
PV conductors10 to 8 AWG[2]
Ground conductorMin. 8 AWG[2]

Protection

AC input breaker≥60A/250V[2]
AC output breaker≥60A/250V[2]
Battery fuse or breaker300A/80V[2]
PV disconnectIntegrated PV switch (DC Switch)[2]

Clearances and orientation

Installation clearancesTop 500 mm, bottom 500 mm, sides 350 mm, front 1000 mm (doors or windows)[2]
Mounting orientationVertical or up to 15° back tilt; connection area downward[2]

Grounding

Grounding and neutral-ground bondingPE busbar in the wiring box; inverter must be grounded; BACKUP/GEN neutral and GRID neutral on separate terminals[2]

Communication

Communication portsBMS; CT/METER; RS485 (4-pin); PARA (4-pin); DRM; RSD; DRY (9-pin: GEN, NTC, RMO, DRY); GPRS/WIFI/LAN[2]

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

SunGoldPower SGN7.6K1HB-48 · SGN7.6K1HB-48

Warranty

Warranty term5 years[2]
Optional extension?
Coverage starts?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?
Registration?
Territory?

Certifications and listings

UL 1741ClaimedListed when checked[2, 4]
UL 1741 SA?
UL 1741 SBClaimedListed when checked[4]ClaimedListed when checked[7]
IEEE 1547ClaimedListed when checked[4]
CA Rule 21?
UL 9540?
FCC Part 15?
UL 1741, Third Edition, Dated September 28, 2021 (including UL 1741 Supplement SB)ClaimedListed when checked[3]
CSA C22.2 No. 107.1:16 (reaffirmed 2021)ClaimedListed when checked[3]
UL 1699B: REVISION, DATED MAY 18, 2021ClaimedListed when checked[3]
CSA C22.2 No. 330:23, Dated February 2023ClaimedListed when checked[3]
UL 1741 Supplement SA (Third Edition, Dated MAY 19, 2023)ClaimedListed when checked[3]
IEEE Std 1547:2018ClaimedListed when checked[3]
CSA C22.2ClaimedListed when checked[2, 4]
UL 1699BClaimedListed when checked[2, 4]
HECO SRD 2.0ClaimedListed when checked[4]
CEC ListedClaimedListed when checked[4]
FCC Part 15 ClassBClaimedListed when checked[2]
CECClaimedListed when checked[7]
CECClaimedListed when checked[7]

Documents and sources

  1. SunGoldPower PowerCore 18K-48 product identityPaid link.Official product feed · Revised Not stated · Checked https://sungoldpower.com/products.json?limit=250&page=1
  2. SGN7.6K1HB-48_User_Manual_20260529.pdfOfficial instruction manual · Revised Not stated · Checked https://cdn.shopify.com/s/files/1/0323/4090/2025/files/SGN7.6K1HB-48_User_Manual_20260529.pdf
  3. SGN_7.6_11.4_K-48_11K15PRO_UL1741_certificate_of_compliance.pdfOfficial certificate · Revised Not stated · Checked https://cdn.shopify.com/s/files/1/0323/4090/2025/files/SGN_7.6_11.4_K-48_11K15PRO_UL1741_certificate_of_compliance.pdf
  4. 7.6KW Hybrid Inverter 48V Split Phase SGN7.6K1HB-48, SunGoldPower product page (September 23, 2026 capture)Paid link.Official product page · Revised Not stated · Checked https://sungoldpower.com/products/7-6kw-hybrid-inverter-48v-split-phase-sgn7-6khb-48
  5. SGS North America certificate of compliance SGSNA/24/GZ/00196 for SGN5KHB-48 to SGN11.4KHB-48 (served by SunGoldPower)Source certificate · Revised Not stated · Checked https://cdn.shopify.com/s/files/1/0323/4090/2025/files/SGN11.4KHB-48_UL_1741.pdf?v=1728370848
  6. SunGoldPower store product data (products.json page 1, 2026-10-27 capture)Paid link.Official product feed · Revised Not stated · Checked https://sungoldpower.com/products.json?limit=250&page=1
  7. CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026)Issuer record · Revised October 1, 2026 · Checked https://solarequipment.energy.ca.gov/Home/DownloadtoExcel?filename=InvertersList