Charged Reviews · Quick reference

SunGoldPower SGN-11K15PRO

Brand
SunGoldPower
Model
SGN-11K15PRO
SKU / part number
SGN-11K15PRO[6]
Category
Inverters
chargedreviews.com/inverters/sungoldpower-sgn-11k15pro

AC output

Continuous output11.4 kW[4]
Peak output150% for 10 s (apparent power)[4]
AC configuration?
AC output voltage120 V / 240 V (Split phase) ,120 V / 208 V (2/3 phase)[4]
AC frequency50 Hz / 60 Hz[4]
Grid pass-through200 A[4]
Maximum output per leg?

Battery

Battery voltage51.2 V[4]
Battery voltage range40 to 64 V[4]
Maximum charge current210 A[4]
Maximum discharge current210 A[4]
Battery-only output10 kW[4]Calculated
Maximum grid charging?
Compatible batteries / BMSLithium-ion/Lead-acid[4]

PV input

PV array limit (connected)15 kW[4, 5]
PV input limit (converted)?
Maximum PV voltage (Voc)600 V[4]
MPPT voltage range70 to 540 V[4]
MPPT trackers3[4]
String inputs per MPPT2 / 2 / 2[4]
PV current per MPPT30 A / 22 A / 22 A[4]
PV short-circuit current40 A / 30 A / 30 A[4]
PV startup voltage90 V[4]

Efficiency and modes

Peak efficiency?
CEC weighted efficiency96.5 %[4]
Battery conversion efficiency?
Grid / off-grid modesSelf-consumption, Feed-in Priority, Back-up and Off Grid modes[4]
Generator inputGEN port, Max. 100 A / 24,000 W[4]
Transfer time10 ms (typical)[4]
Idle consumption?
Parallel units?

Communication and environment

CommunicationsCAN (for BMS); RS485 (for meter); RS485; CAN (for parallel); Optional: WiFi / LAN[4]
Operating temperature-25 to 60 °C[4]
Enclosure ratingNEMA 3R[4]
Operating noise?

Mechanical

Dimensions270 D × 448 W × 901 H mm[4]
Weight47 kg / 103.62 lb[4]

Installation (from the manual)

Torque

AC terminal torqueGRID 165 lb-in (18.6 N·m); LOAD 165 lb-in (18.6 N·m); GEN 110 lb-in (12.4 N·m); neutral busbar 94 lb-in (10.6 N·m)[4]
Battery terminal torque106 in-lb(11.98 N·m*)[4]
PV terminal torque?
Ground terminal torque94 in-lb(10.62 N·m*)[4]

Conductors

Battery conductors2 AWG (2pcs) or 4/0 AWG[4]
AC input conductorsGRID 2/0 AWG to 4/0 AWG; GEN 1 AWG to 1/0 AWG[4]
AC output conductors2/0 AWG to 4/0 AWG[4]
PV conductors10 AWG to 8 AWG[4]
Ground conductor1/0 AWG to 2/0 AWG (GEN: 1 AWG to 1/0 AWG)[4]

Protection

AC input breakerExternal breaker required between the grid and the inverter, sized to applicable electrical code[4]
AC output breakerIntegrated (2*200 A)[4]
Battery fuse or breakerIntegrated battery breaker (300 A)[4]
PV disconnectIntegrated PV switch (DC Switch)[4]

Clearances and orientation

Installation clearances1000 mm to doors/windows; 500 mm vertical; 350 mm side[4]
Mounting orientationVertical or up to 15° back tilt; connection area downward[4]

Grounding

Grounding and neutral-ground bondingIntegrated PE busbar; inverter must be grounded; PV+/PV- ungrounded[4]

Communication

Communication portsBMS; CT/METER; DRMS; RSD; GEN (9-pin); NTC; RMO; DRY; PARAL (4-pin); RS485 (4-pin); Wi-Fi[4]

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

SunGoldPower SGN-11K15PRO · SGN-11K15PRO

Warranty

Warranty term?
Optional extension?
Coverage starts?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?
Registration?
Territory?

Certifications and listings

UL 1741ClaimedListed when checked[4]
UL 1741 SAClaimedListed when checked[4]ClaimedListed when checked[7]
UL 1741 SBClaimedListed when checked[4]ClaimedListed when checked[7]
IEEE 1547ClaimedListed when checked[4]
CA Rule 21?
UL 9540?
FCC Part 15?
UL 1741, Third Edition, Dated September 28, 2021 (including UL 1741 Supplement SB)ClaimedListed when checked[2]
CSA C22.2 No. 107.1:16 (reaffirmed 2021)ClaimedListed when checked[2]
UL 1699B: REVISION, DATED MAY 18, 2021ClaimedListed when checked[2]
CSA C22.2 No. 330:23, Dated February 2023ClaimedListed when checked[2]
UL 1741 Supplement SA (Third Edition, Dated MAY 19, 2023)ClaimedListed when checked[2]
IEEE Std 1547:2018ClaimedListed when checked[2]
CSA C22.2ClaimedListed when checked[4]
UL 1699BClaimedListed when checked[4]
FCC Part 15 Class BClaimedListed when checked[4]
UL 1741 PCS CRDClaimedListed when checked[4]
HECO SRD 2.0ClaimedListed when checked[4]
CSIPClaimedListed when checked[4]
CECClaimedListed when checked[7]
CECClaimedListed when checked[7]

Documents and sources

  1. SunGoldPower PowerCore 18K-48 product identityPaid link.Official product feed · Revised Not stated · Checked https://sungoldpower.com/products.json?limit=250&page=1
  2. SGN_7.6_11.4_K-48_11K15PRO_UL1741_certificate_of_compliance.pdfOfficial certificate · Revised Not stated · Checked https://cdn.shopify.com/s/files/1/0323/4090/2025/files/SGN_7.6_11.4_K-48_11K15PRO_UL1741_certificate_of_compliance.pdf
  3. 11.4KW Hybrid Inverter 48V Split Phase SGN-11K15PRO Data SheetOfficial datasheet · Revised Not stated · Checked https://cdn.shopify.com/s/files/1/0323/4090/2025/files/SGN-11K15PRO_Inverter.pdf
  4. 11.4KW Hybrid Inverter 48V Split Phase SGN-11K15PRO User ManualOfficial instruction manual · Revised Not stated · Checked https://cdn.shopify.com/s/files/1/0323/4090/2025/files/11.4K15PRO_20260514.pdf
  5. 11.4KW 48V Split Phase Hybrid Solar Inverter | Whole Home Backup (200A) | SGN-11K15PRO, SunGoldPower product page (September 23, 2026 capture)Paid link.Official product page · Revised Not stated · Checked https://sungoldpower.com/products/11-4kw-48v-split-phase-hybrid-solar-inverter-whole-home-backup-200a-sgn-11k15pro
  6. SunGoldPower store product data (products.json page 1, 2026-10-27 capture)Paid link.Official product feed · Revised Not stated · Checked https://sungoldpower.com/products.json?limit=250&page=1
  7. CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026)Issuer record · Revised October 1, 2026 · Checked https://solarequipment.energy.ca.gov/Home/DownloadtoExcel?filename=InvertersList