locator: SunGoldPower product data (products.json, page 1), listing "3000W DC 24V Pure Sine Wave Inverter With Charger" (handle 3000w-peak-9000w-dc-24v-pure-sine-wave-inverter-with-charger), option "Only Inverter", "sku":"LFP3K24V120VSG"
conditions: SunGoldPower's own product data, captured 2026-10-27, prints SKU "LFP3K24V120VSG" for option "Only Inverter" (variant 39652727619721) of listing "3000W DC 24V Pure Sine Wave Inverter With Charger".
Grounding terminal to the earth grounding system or the vehicle chassis; automatic neutral-to-ground relay bonds the output neutral to ground in inverter mode and opens on qualified external AC (single-phase 120Vac models), can be disabled
Printed as "earth grounding system or the vehicle chassis" (section 3.4) and "All single-phase 120Vac inverters are equipped with an automatic neutral-to-ground switch" (section 3.4.1) in the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed); section 3.4.2 describes disabling it by separating the green wire connector, for example when connecting to a house panel that already has the neutral to ground bond. This is a 120 V single-phase model.
Where: PDF page 20, sections 3.4 Grounding, 3.4.1 and 3.4.2 Automatic Neutral-to-Ground Connection
The manual and the product page print different weights. The LFP Series user manual prints 24KG for its 3KW column; the product page prints 48.5LB (22 kg).
Printed as "24KG" in the 3KW column of the Inverter Weight row (unit weight; shipping weight is a separate row) in the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed). The table's columns are by power only; the 3KW column is this 3KW model. Revised on 1 October 2026: The user manual prints 24KG for the 3KW column, which differs from the pound figure on the product page; the manual is the primary source and the earlier value is kept as an alternative.
Printed once as "THD < 10%" for every model column in the table (merged cell). The manual's table has columns by power only (1KW to 6KW) and covers the whole LFP series.
Where: LFP Series Pure Sine Wave Inverter/Charger User's Manual (LFP_Series_Manual_20240711), Appendix 1 Specifications, Inverter Output, THD row
At least 30CM (11.81 inches) of clearance around the inverter
Printed as "Allow at least 30CM(11.81 inches) of clearance around the inverter for air flow" in item 1-1-1 of the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed), which also prints "A minimum air flow of 145CFM is required" and says not to install the inverter in a zero-clearance compartment.
Where: PDF page 4, section 1.1 General Safety Precautions, item 1-1-1
W 242 × H 198 × L 505 mm / W 9.53 × H 7.8 × L 19.9 in convertedCheck note
The manual and the product page print different dimensions. The LFP Series user manual prints 505*242*198mm (L*W*H) for its 2KW to 4KW models; the product page prints 22.05 x 9.1 x 7.5 inch (560.1 x 231.1 x 190.5 mm).
Printed as "505*242*198mm" in the row labeled "Dimensions(L*W*H)" (length, width, height) in the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed); the figure spans the 2KW to 4KW columns (merged cell), confirmed on the rendered page, so it applies to this 3KW model. Revised on 1 October 2026: The user manual prints 505*242*198mm (L*W*H) for this power class, which differs from the inch figures on the product page; the manual is the primary source and the earlier figures are kept as an alternative.
Where: PDF page 26, Appendix 1 Mechanical Specification, Inverter Dimensions(L*W*H) row, 2KW to 4KW merged cell
Sources
W 231.1 × H 190.5 × L 560.1 mm
Printed as "22.05 x 9.1 x 7.5 inch" (Unit Size) without naming which dimension is which; kept in printed order and converted from inches.
Printed as "Nominal Efficiency >88%(Peak)", a lower bound on peak efficiency, not an exact value, in the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed). Section 2.5.2 also prints "The peak efficiency of LFP series is 88%". Printed once across every column of the table (merged cell), so it applies to this model. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to SunGoldPower (sungoldpower.com), which stays listed as an additional source.
Where: PDF page 25, Appendix 1 Inverter & AC Charger Electrical Specifications, Nominal Efficiency row, all columns
Printed as "Output Frequency 50/60Hz ± 0.3Hz" in the specification table of the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed). Printed once across every column of the table (merged cell), so it applies to this model. Section 2.5.3 says the output frequency adjusts automatically to a qualified input frequency, with a factory default of 60Hz for 100/110/120VAC inverters. Revised on 1 October 2026: The user manual's specification table prints the output frequency with its tolerance; the manual becomes the primary source and the product page wording is kept as an alternative.
Where: PDF page 25, Appendix 1 Inverter & AC Charger Electrical Specifications, Output Frequency row, all columns
Sources
50 or 60Hz
Printed as "it can output 50 or 60Hz via the SW4"; the output frequency is selected by DIP switch SW4.
Printed as "24 Vdc 40 ± 5 Amp" (AC Charger Current Max, a tolerance of plus or minus 5 A) in the 3.000 Model Watt, 24 Vdc row of "Tabel 2.5.3 AC Charging Current for OIS model" in the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed); the table layout was confirmed on the rendered page. The manual states the maximum charge current can be adjusted from 0% to 100% with a linear switch. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to SunGoldPower (sungoldpower.com), which stays listed as an additional source.
Where: PDF page 10, section 2.5.1 AC Charger, Tabel 2.5.3 AC Charging Current for OIS model, AC Charger Current Max column, 3.000 Model Watt / 24 Vdc row
Printed as "Connect an AWG 8 gauge or greater copper wire between the grounding terminal on the inverter and the earth grounding system or the vehicle chassis" in section 3.4 of the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed).
Printed as "Typical transfer Time 10ms(Max)" in the specification table of the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed). Printed once across every column of the table (merged cell), so it applies to this model. Elsewhere the same manual prints "8 ms Typical Transfer Time Between Utility & Battery" (features list) and says the transfer "occurs in approximately 8 milliseconds" (section 2.5.5); the table figure is a maximum. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to SunGoldPower (sungoldpower.com), which stays listed as an additional source.
Where: PDF page 25, Appendix 1 Inverter & AC Charger Electrical Specifications, Typical transfer Time row, all columns
Printed as "3KW 24V AWG 1/0" in the DC wiring table (Power, DC Input voltage, Wire Gage) of the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed); the manual calls it the minimum wire size for a 3 meter DC cable and says to increase the cross section for longer cables.
Where: PDF page 18, section 3.2 DC Wiring recommendation, 3KW 24V row, Wire Gage column
Auto Gen Start (customizable): starts a generator with an auto start function at low battery and stops it when charging is finished; relay up to 16 A; 15-second delay before transfer to generator
Printed as "The inverter can be customized to start up a generator when battery voltage goes low" and "the Max current the relay can carry is 16Amp" (Auto Gen Start), with "Generator must have auto start function", in the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed); section 2.5.5 prints a 15-second delay before transfer so a generator can spin up.
Where: PDF page 17, section 2.5.13 Other features, Auto Gen Start; PDF page 12, section 2.5.5 Transfer
Printed as "9000W" in the 3KW column of the row labeled "Surge Rating(20s)" in the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, no date printed). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to SunGoldPower (sungoldpower.com), which stays listed as an additional source.
Where: PDF page 25, Appendix 1 Inverter & AC Charger Electrical Specifications, Surge Rating(20s) row, 3KW column
Exact wording of the AC input range for grid or generator; the two ranges are selected by DIP switch SW2. The Inverter Output section separately prints "AC Input: 120VAC".
Where: SunGoldPower product page for LFP3K24V120VSG, Specification tab, AC Charger, AC input Range (Grid or Generator)
Printed as "We recommend using 10 to 6Awg wire to connect to the AC terminal block" in section 3.3 of the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed), one recommendation for the AC terminal block of every model. The manual adds "a thicker wire gauge for AC Input is required" because the AC input supplies both the loads and the charger, and refers the choice to a qualified electrician.
Printed as "We recommend using 10 to 6Awg wire to connect to the AC terminal block" in section 3.3 of the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed), one recommendation for the AC terminal block of every model.
Printed as "3000W" in the 3KW column of the Continuous Output Power row of the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed); converted from W to kW. The table's columns are by power only; the 3KW column is this 3KW model. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to SunGoldPower (sungoldpower.com), which stays listed as an additional source.
Where: PDF page 25, Appendix 1 Inverter & AC Charger Electrical Specifications, Continuous Output Power row, 3KW column
Printed as "Mounting Wall mount" in the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed). Printed once across every column of the table (merged cell), so it applies to this model. No orientation is stated.
Where: PDF page 26, Appendix 1 Mechanical Specification, Mounting row, all columns
Battery type selector: Gel USA, AGM 1, Lithium/AGM2, Lithium/Sealed Lead Acid, Gel EURO, Lithium, LiFePO4, Classic LFP, plus De-sulphation and Charger Off; lithium batteries such as LiFePO4 when the charge settings suit the battery
Printed as "Table 2.5.2 Battery Type Selector" (settings 0 to 9) and "Our inverter charger can work with various lithium batteries like LiFePO4, LFP battery" in the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed), which asks the user to check that the charging setting suits the lithium battery and offers customization by email. No battery communication (BMS) link is described.
Where: PDF page 10, section 2.5.1 AC Charger, Table 2.5.2 Battery Type Selector and Use with Lithium Ion Battery Packs
Printed as "Working temperature: ‐10℃‐40℃" in section 3.1 of the LFP Series Pure Sine Wave Inverter/Charger User's Manual (series edition with columns 1KW to 6KW, number 614-00510-04 on the back cover, no date printed), stated for the series; storage temperature is printed separately as "‐40‐70℃".
Where: PDF page 18, section 3.1 Location, Working temperature line
Lowest first. Each price is the date we last read it; it may have changed. Stock isn't shown.
Store
Price
Read
Details
Source
SunGoldPower
$859
Oct 31, 2026
Price SunGoldPower's product data prints for this exact variant (option "Only Inverter", SKU LFP3K24V120VSG) on October 31, 2026: "price":"859.00", $859.00. The data also prints a compare-at price, not recorded as a price. One unit as listed; shipping and tax are not included. · Store SKU LFP3K24V120VSGPrice readings (1)
24.2 L* (Calculated from published dimensions)W: 242 × H: 198 × L: 505 mm / W: 9.53 × H: 7.8 × L: 19.9 inWeight24 kg / 53 lb
Evidence score
3/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term1 year1.2 / 30.0
1 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed once as "Standard Warranty 1 Year" for every model column in the table (merged cell), in the manual dated 20240711. The manual's table has columns by power only (1KW to 6KW) and covers the whole LFP series.
Research pending, 0 points: Certificates, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Warranty term
1 years
Printed once as "Standard Warranty 1 Year" for every model column in the table (merged cell), in the manual dated 20240711. The manual's table has columns by power only (1KW to 6KW) and covers the whole LFP series.
Where: LFP Series Pure Sine Wave Inverter/Charger User's Manual (LFP_Series_Manual_20240711), Appendix 1 Specifications, Mechanical Specification, Standard Warranty row
SunGoldPower publishes this instruction manual for LFP4K12V240VSP and names no other model in this catalog on it. Read from https://sungoldpower.com/collections/power-inverter on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.
Location: Document title as published
Retrieved Sep 19, 2026
SunGoldPower publishes this instruction manual for LFP4K12V240VSP and names no other model in this catalog on it. Read from https://sungoldpower.com/collections/power-inverter on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.
Archived copy of a document published by SunGoldPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-23.
Location: Product heading; Highlight list; Specification and User Manual tabs (manual-download-button links)
Retrieved Sep 22, 2026
SunGoldPower's own product page, captured byte for byte on September 23, 2026. It establishes what SunGoldPower published for LFP3K24V120VSG on that date: the page heading, the Highlight text, the variant selector (SKUs LFP3K24V120VSG, LFP3K24V120VSG+2*LFP24-100A, LFP3K24V120VSGRE) and the 1 document link(s) under its User Manual tab. Prices and stock on the page are the state of a promotional storefront and are not recorded from it. A specification quoted from the page is SunGoldPower's own published figure, not a test result.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
4KW 12V Pure Sine Wave Split Phase Inverter Charger User Manual
Archived copy of a document published by SunGoldPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.