AC output
- Continuous output
- 1 kW [1]
- AC configuration
- 230 V AC (Single-Phase) [2]
- AC output voltage
- 230 V [2]
- AC frequency
- 50Hz ± 0.3Hz/60Hz ± 0.3Hz [1]
- Grid pass-through
- 6.5 A [1]
- Maximum output per leg
- ?
Battery
- Battery voltage range
- 10.5 to 15.5 V [1]
- Maximum charge current
- 120 A [1]
- Maximum discharge current
- ?
- Battery-only output
- ?
- Maximum grid charging
- 60 A [1]
- Compatible batteries / BMS
- Lead-acid or lithium batteries [1]
PV input
- PV array limit (connected)
- 1 kW [2]
- PV input limit (converted)
- ?
- Maximum PV voltage (Voc)
- 108 V [2]
- MPPT voltage range
- 15 to 90 V [2]
- String inputs per MPPT
- ?
- PV current per MPPT
- ?
- PV short-circuit current
- ?
- PV startup voltage
- ?
Efficiency and modes
- CEC weighted efficiency
- ?
- Battery conversion efficiency
- ?
- Grid / off-grid modes
- ?
- Generator input
- ?
- Transfer time
- typical: 10 [1]
- Idle consumption
- ?
- Parallel units
- ?
Communication and environment
- Communications
- USB; RS485; WiFi (optional); GPRS (optional) [1]
- Operating temperature
- -10 to 55 C / 14 to 131 °F converted [1]
- Operating noise
- ?
Mechanical
- Dimensions
- 357.5 × 235 × 103 mm / 14.07 × 9.25 × 4.06 in converted [2]
- Weight
- 5.5 kg / 12 lb converted [2]
Installation (from the manual)
Conductors
- Battery conductors
- 22mm2/3AWG [1]
- AC output conductors
- 2mm2/12AWG [1]
- PV conductors
- 9mm2/8AWG [1]
- Ground conductor
- ?
Protection
- Breakers / fuses
- Battery breaker 2P—140A; PV breaker 2P—40A; AC input breaker 2P—10A; AC output breaker 2P—10A [1]
- AC input breaker
- ?
- AC output breaker
- ?
- Battery fuse or breaker
- ?
- PV disconnect
- ?
Not in the manual: Torque, Clearances and orientation, Grounding, Communication