AC output
- Continuous output
- 16 kW [1]
- Peak output
- 32000 VA for 10 s [2]
- AC configuration
- Three-phase [2]
- AC output voltage
- ?
- AC frequency
- ?
- Grid pass-through
- 60 A [1]
- Maximum output per leg
- ?
Battery
- Battery voltage range
- ?
- Maximum charge current
- 300 A [1]
- Maximum discharge current
- ?
- Battery-only output
- ?
- Maximum grid charging
- 300 A [1]
- Compatible batteries / BMS
- Lithium-ion, lead-acid or user-defined batteries [1]
PV input
- PV array limit (connected)
- ?
- Maximum PV voltage (Voc)
- 1,000 V [2]
- MPPT voltage range
- 160 to 850 V [2]
- String inputs per MPPT
- ?
- PV current per MPPT
- ?
- PV short-circuit current
- 60 A [1]
- PV startup voltage
- ?
Efficiency and modes
- Peak efficiency
- ?
- CEC weighted efficiency
- ?
- Battery conversion efficiency
- ?
- Grid / off-grid modes
- ?
- Generator input
- Generator input; max. generator charging current 300A [1]
- Transfer time
- ?
- Idle consumption
- ?
- Parallel units
- 9 count [2]
Communication and environment
- Communications
- ?
- Operating temperature
- ?
- Operating noise
- ?
Mechanical
- Dimensions
- W 706 × H 466 × D 313 mm / W 27.8 × H 18.3 × D 12.3 in converted [2]
- Weight
- 49.5 kg / 109 lb converted [2]
Installation (from the manual)
Conductors
- Battery conductors
- 70mm²/ 00 [1]
- AC output conductors
- 14mm²/6AWG(L1/L2/L3/N) [1]
- PV conductors
- 6mm²/ 10 [1]
- Ground conductor
- ?
Protection
- Breakers / fuses
- Battery breaker 2P-180A; PV breaker 2P-50A; grid breaker 4P-70A; generator breaker 4P-50A; load breaker 4P-70A [1]
- AC input breaker
- ?
- AC output breaker
- ?
- Battery fuse or breaker
- ?
- PV disconnect
- ?
Not in the manual: Torque, Clearances and orientation, Grounding, Communication